The 1756-OB16IS is a digital output execution component built for the ControlLogix system configuration. It functions within a nominal 12/24V DC voltage envelope, featuring 16 channels that are isolated individual points designed to secure downstream circuitry against cross-signal disturbance and transient spikes. This module integrates 8 scheduled output points designed to enable precise synchronization matching coordinated machine sequences with reference to the Coordinated System Time. It installs inside standard control slots, interfacing with industrial field loads via specified removable termination assemblies to provide deterministic actuation and steady processing states under multiple manufacturing control configurations.

Features

  • Incorporates 16 isolated output channels providing basic insulation between output points and backplane circuits.
  • Features 8 scheduled outputs allowing time-stamped task performance linked directly with coordinated control architecture.
  • Provides sinking or sourcing load matching with an execution range spanning 10V DC to 30V DC field operations.
  • Delivers continuous visual verification of independent output channel execution states and module hardware health.
  • Supports electronic, software-configurable keying options to enforce accurate hardware module matching upon slot replacement.

Applications

  • High-speed sorting and discrete tracking machinery requiring timed sequence control.
  • Solenoid valve switching loops and isolated pilot relay driving circuits.
  • Multi-zone industrial heating elements requiring synchronized control pulses.

Technical Specifications

Parameter Specification
Outputs 16 individually isolated, 8 scheduled
Pilot Duty 2 A (DC-13SQ)
Voltage Category 12/24V DC sink/source
Operating Voltage Range 10...30V DC
Output Delay Time (Off to On) 1 ms max
Output Delay Time (On to Off) 2 ms max
Current Draw @ 5.1V 350 mA
Current Draw @ 24V 2.5 mA
Total Backplane Power 1.8 W
Power Dissipation, Max 3.6 W @ 60 degC (140 degF)
Thermal Dissipation 12.28 BTU/hr
Off-State Leakage Current Per Point, Max 0.5 mA per point
On-State Voltage Drop, Max 1.2V DC @ 2 A
Current Per Point, Max 2 A @ 30 degC (86 degF), 1 A @ 60 degC (140 degF) (linear derating)
Current Per Module, Max 8 A @ 30 degC (86 degF), 4 A @ 60 degC (140 degF) (linear derating)
Surge Current Per Point 4 A for 10 ms per point, repeatable every 2 s
Load Current, Min 1 mA per point
Scheduled Outputs Synchronization Within 16.7 s max, reference to the Coordinated System Time
States in Fault Mode Per Point Hold last state, On or Off (Off is default)
States in Program Mode Per Point Hold last state, On or Off (Off is default)
Isolation Voltage 250V (continuous), basic insulation type, outputs-to-backplane, and output-to-output
Module Keying Electronic, software configurable
Removable Terminal Block 1756-TBCH, 1756-TBS6H
RTB Keying User-defined mechanical
Slot Width 1
Wire Category 1
Wire Type Copper
Enclosure Type None (open-style)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 2 g @ 10...500 Hz
Shock, Operating 30 g
Shock, Nonoperating 50 g
Emissions IEC 61000-6-4

Installation Guidelines

  • Ensure conductor routing follows specified guidelines for Wire Category 1 paths to reduce crosstalk with high-voltage power components.
  • Use only approved ControlLogix Removable Terminal Blocks, specifically models 1756-TBCH or 1756-TBS6H, to wire external field outputs.
  • Set the software-based electronic keying attributes accurately within the project configuration to prevent mismatched module replacement errors.
  • Apply appropriate current derating factors when operating ambient conditions rise, limiting per-point current to 1 A when reaching 60 degC.
  • Mount the open-style chassis assembly inside an enclosure that offers appropriate protective barrier sealing against environmental particulates.

Compliance and Certifications

  • cULus Listed Industrial Control Equipment (UL File E65584)
  • cULus Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations (UL File E194810)
  • CE (European Union 2014/30/EU EMC Directive, EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2; 2014/35/EU LVD Directive, EN 61131-2)
  • RCM (Australian Radiocommunications Act, EN 61000-6-4)
  • ATEX (European Union 2014/34/EU ATEX Directive, EN IEC 60079-0, EN IEC 60079-7, II 3 G Ex ec IIC T4 Gc, UL22ATEX2820X)
  • IECEx (IEC 60079-0, IEC 60079-7, II 3 G Ex ec IIC T4 Gc, IECEx UL 22.0065X)
  • UKex (UKEX Regulation 2016 No. 1107, Equipment protection by increased safety "e", UL22UKEX2602X, Zone 2 classification)
  • KC (Korean Registration of Broadcasting and Communications Equipment, Article 58-2 of Radio Waves Act)
  • UKCA (2016 No. 1091, 2016 No. 1101, 2016 No. 1107, 2012 No. 3032)
  • Morocco (Arrête ministériel n° 6404-15)
  • CCC (2020122309111998, CNCA-C23-01 CCC Implementation Rule Explosion-Proof Electrical Products)
Loading product navigation…

Каков порог непрерывной изоляции, обеспечиваемый устройством?

Устройство обеспечивает номинальное напряжение непрерывной изоляции 250 В с использованием базовой изоляции на путях соединения выходов с задней панелью и выходов между собой.

Как условия окружающей среды влияют на максимальный допустимый ток на точку?

Максимальный ток на точку составляет 2 А при работе при температуре окружающей среды до 30 °C, затем линейно снижается до 1 А при достижении температуры 60 °C.

Что происходит с выходами, когда контроллер переключается в режим Ошибка или Программа?

Каждый выходной канал можно настроить на удержание последнего состояния, включение или выключение. По умолчанию для обоих режимов задано состояние Выключено.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Color pattern
Черный
Country of origin
Соединённые Штаты
Power source
Постоянный ток

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...