1 из 1

Beckhoff KS3064 Bus Terminal 4-Channel Analog Input Module

Beckhoff KS3064 Bus Terminal 4-Channel Analog Input Module

Остался в наличии только 10 товар(ы)
  • Производитель: BECKHOFF

  • Номер продукта: KS3064

  • Страна происхождения:Германия

  • Тип продукта: Bus Terminals

  • Оплата: Т/Т, Western Union

  • Вес: 80г

  • Размеры: 12 mm x 100 mm x 68 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

To facilitate precise voltage acquisition in dense processing environments, the Beckhoff KS3064 analog input terminal digitizes field-side signals from 0 to 10 V DC with 12-bit resolution. As part of the premium pluggable KSxxxx series, this 4-channel single-ended module integrates highly reliable performance with a hot-swappable terminal block design, enabling quick hardware change-outs without disturbing existing field wiring. It communicates directly with the primary industrial controller via the standard K-bus interface, combining high processing efficiency with minimal space requirements.

Features

  • Four Single-Ended Inputs: Allows simultaneous monitoring of four independent 0 to 10 V analog signals.
  • Pluggable Wiring Interface: Front-facing tension-clamp connector block is easily removable, reducing maintenance downtime and simplifying cabinet retrofits.
  • 12-Bit Analog-to-Digital Conversion: Delivers sharp resolution for highly accurate PLC and DCS monitoring applications.
  • Galvanic Isolation: Provides robust 500 V electrical isolation between the internal K-bus and the process circuitry, defending control hardware from voltage spikes.
  • Compact 12 mm Footprint: Modular housing saves valuable DIN-rail space inside control panels.

Applications

  • Process Sensor Monitoring: Acquires signal inputs from flow meters, pressure transmitters, and distance sensors.
  • HVAC Control Integration: Collects temperature and humidity voltage signals from environmental monitoring units.
  • Machinery Control Platforms: Acts as the analog interface for OEM assembly equipment, handling variable system feedback.

Technical Specifications

Specification Parameter Value / Detail
Manufacturer Beckhoff
Model Number KS3064
Module Type 4-Channel Analog Input (Single-Ended)
Signal Voltage Range 0 to 10 V DC
Internal Resistance > 200 kOhm (typical)
Resolution 12 bit
Conversion Time Approx. 4 ms
Measuring Error < +/- 0.3 % (relative to full scale value)
K-Bus Current Consumption Typ. 85 mA
Electrical Isolation 500 V (K-bus / signal voltage)
Connection Method Pluggable spring-actuated terminal block
Connection Cross-Section Solid/Stranded: 0.08 to 1.5 mm2 (AWG 28 to 16)
Operating Temperature Range -25 to +60 degC
Storage Temperature Range -40 to +85 degC
Protection Class IP20
Ex Marking II 3 G Ex nA IIC T4 Gc (ATEX certified)
Country of Origin Germany
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Unit Weight 0.08 kg

Connections & Interfaces

Terminal Pin Number Signal Type Description
1 Input 1 (+) Voltage input channel 1 (0 to 10 V)
5 Input 2 (+) Voltage input channel 2 (0 to 10 V)
2 Input 3 (+) Voltage input channel 3 (0 to 10 V)
6 Input 4 (+) Voltage input channel 4 (0 to 10 V)
3, 7, 4, 8 Common GND Internal common reference ground points (0 V)

Empirical Engineering Insights

Alternative Models & Compatibility

The KS3064 functions identically to the standard KL3064 Bus Terminal. The critical system-level distinction is the physical terminal interface; the KS3064 employs a pluggable terminal system, while the KL3064 utilizes fixed tension clamps. Both share exact software mappings in TwinCAT 2 and TwinCAT 3 systems. If replacing a KL3064, no modifications are required within the PLC configuration.

Application Pitfalls & Engineering Notes

Because this is a single-ended terminal, all 4 input channels share a common internal ground reference linked directly to the system's external ground. If integrating transmitter signals sourced from different, isolated field power supplies, any potential offsets between the power supplies will introduce measurement offset errors. To preserve the 12-bit measurement integrity, ensure that all sensor reference grounds are bonded to a common equipotential earth system.

Commissioning & Wiring Tips

Analog signals in the 0 to 10 V range are highly susceptible to high-frequency electromagnetic interference from surrounding VFDs and power contacts. It is vital to use shielded twisted-pair cabling. Always ground the signal shield only at the central control cabinet ingress plate rather than terminating the shield to the terminal blocks, to avoid creating ground loop currents across the internal K-bus.

Installation Guidelines

CRITICAL WARNING: Completely de-energize the PLC master power and isolate all field connections prior to mounting, dismounting, or pulling the pluggable wiring head from the KS3064 housing. Removing the module or terminal strip under active load can corrupt K-bus communication registers, causing unexpected bus master shutdowns and terminal diagnostic faults.
  1. 1

    Align the KS3064 terminal housing with the 35 mm DIN rail (EN 60715) and push firmly until the locking mechanism clicks audibly.

  2. 2

    Slide the terminal adjacent to the surrounding K-bus modules until the integrated tongue-and-groove side locking tracks slot securely together.

  3. 3

    Insert pre-stripped wire conductors (stripped length: 9 to 10 mm) into the pluggable tension-clamp terminal by depressing the spring actuator latch with a flat-head terminal screwdriver.

  4. 4

    Seat the pluggable terminal connector block firmly into the KS3064 front housing interface until it is fully retained.

Loading product navigation…

What is the primary difference between the Beckhoff KS3064 and KL3064 modules?

The KS3064 features a removable, pluggable terminal connector block on the front housing. The KL3064 uses fixed tension-clamps. Internally, they share the identical electrical, software, and K-bus architecture.

Do the input channels on the KS3064 have independent grounds?

No. The KS3064 utilizes a single-ended architecture, meaning all four analog input channels share a common internal signal ground (0 V reference) inside the bus terminal.

How is the module powered, and does it require external power contacts?

The KS3064 draws its operating current of typically 85 mA directly from the K-bus via the Bus Coupler. It does not possess power contacts and does not require external field-side terminal supply voltage to operate.

Which software platforms support the configuration of this Bus Terminal?

The KS3064 is fully supported across all TwinCAT programming environments (TwinCAT 2 and TwinCAT 3) via the standard Beckhoff System Manager, requiring no specialized hardware description files.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Германия

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...