1 из 1

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

Остался только 7 товар(ы) на складе
  • Производитель: Bently Nevada

  • Номер продукта: 136180-01+136188-01

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: Communication Gateway Modules

  • Оплата: Банковский перевод (T/T), Western Union

  • Вес: 1260г

  • Размеры: 241.3 mm x 48.8 mm x 241.3 mm (H x W x D)

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

The 136180-01+136188-01 combination consists of the 3500/92 Communication Gateway Module main card (136180-01) and the associated Ethernet/RS232 Modbus I/O Module rear card (136188-01). This module set establishes digital communication links between the Bently Nevada 3500 Machinery Protection System and external plant automation platforms.

The gateway collects static measurement data, system event lists, and alarm statuses directly from the 3500 rack backplane and translates the information into standard Modbus protocols. Utilizing the 136188-01 rear I/O card, it offers hardware interfaces for Modbus communication over Ethernet networks and point-to-point RS232 serial connections. Plant operators use the 136180-01+136188-01 to integrate vibration monitoring values, thrust positioning, and system diagnostic events directly into Distributed Control Systems (DCS), Programmable Logic Controllers (PLC), and Human-Machine Interfaces (HMI).

Features

  • Integrates the 3500/92 main monitor board with an Ethernet/RS232 rear I/O card.
  • Supports Modbus TCP/IP communication over Ethernet and Modbus RTU/ASCII over serial connections.
  • Transmits static values, alarm events, and system statuses across redundant digital channels.
  • Configurable Modbus register mapping via 3500 System Rack Configuration Software.
  • Maintains galvanic isolation between field interfaces and the internal rack logic.

Applications

  • Integration of 3500 machinery protection data into DCS and PLC networks
  • Remote monitoring of turbomachinery static vibration and position parameters
  • Industrial automation control loops requiring real-time machinery state data
  • Plant-wide condition monitoring and data historian integration

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Main Card Part Number 136180-01
I/O Module Part Number 136188-01
Module Type Communication Gateway Module + Ethernet/RS232 Modbus I/O Module
Protocols Modbus TCP/IP, Modbus RTU, Modbus ASCII
Ethernet Port 10BASE-T / 100BASE-TX
Serial Port RS232 (Configurable baud rate)
Operating Temperature -30 degC to +65 degC (-22 degF to +149 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Humidity 95%, noncondensing
Rack Space 1 full-height front slot (Main Card) + 1 full-height rear slot (I/O Card)

Connections and Interfaces

Port / Terminal Function
RJ45 Ethernet Modbus TCP/IP Network Connection
RS232 Serial Port Serial Modbus RTU / ASCII Connection

Installation Guidelines

  • Install the 136180-01 main card into a full-height slot on the front of the 3500 rack.
  • Mount the 136188-01 I/O module in the rear of the rack directly behind the 136180-01 main card.
  • Ensure cable shields are grounded according to system installation practices to minimize EMI/RFI noise.
  • Configure Modbus slave address, baud rate, and network IP settings through the 3500 System Configuration Software prior to commissioning.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 136180-01+136188-01 3500/92 Communication Gateway Module + Ethernet/RS232 Modbus I/O Module

What protocols are supported by the communication module?

The module supports Modbus TCP/IP via its Ethernet interface as well as Modbus RTU and Modbus ASCII over its RS232 serial interface.

Where is the I/O module installed in the rack?

The I/O module installs into a full-height slot at the rear of the 3500 rack directly behind the main communication gateway card.

How are the communication settings configured on the device?

All network settings, serial baud rates, and Modbus register maps are configured using the 3500 System Rack Configuration Software.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, оформленных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Модернизация человеко-машинных интерфейсов Bailey INFI 90 Symphony под управлением OpenVMS Alpha

Практическое руководство по замене устаревающих операторских станций Bailey Symphony на базе OpenVMS Alpha. В нём сравниваются эмуляция Alpha, миграция на OpenVMS x86, перенос на платформу OPC и...

Почему данные о техническом обслуживании необходимы для обеспечения надёжности промышленного оборудования

Данные о техническом обслуживании объединяют рабочие заказы, сигналы датчиков, историю активов, затраты и знания технических специалистов. При правильном использовании они улучшают планирование,...

Электрические приводы, разработанные для замены гидравлических и пневматических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator компании SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для приложений промышленной автоматизации

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, вычисление остатка от деления и возведение в степень, в...