1 из 3

GE IS420UCECH1B Mark VIe & VIeS UCEC Controller Module

GE IS420UCECH1B Mark VIe & VIeS UCEC Controller Module

Остался только 7 товар(ы) на складе
  • Производитель: General Electric

  • Номер продукта: IS420UCECH1B

  • Страна происхождения:Соединённые Штаты,Германия

  • Тип продукта: UCEC Controller Module

  • Штрихкод: 8537101190

  • Оплата: Т/Т, Western Union

  • Вес: 2060г

  • Размеры: 204 x 153 x 85 mm

  • Порт отгрузки: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

GE IS420UCECH1B Mark VIe & VIeS UCEC Controller Module

Description

The IS420UCECH1B acts as a high-density core processing unit and communication hub within General Electric's Mark VIe and Mark VIeS control systems. This module integrates a base UCSCH1x controller platform directly with a specialized seven-port RJ-45 I/O expansion board. The IS420UCECH1B UCEC controller module handles high-speed industrial control loop logic and data routing across dual-redundant or Triple Modular Redundant (TMR) safety networks. It manages simultaneous data streams via the Unit Data Highway (UDH) for operator interfaces and the dedicated IONet fieldbus for high-speed I/O communication. Built with integrated hardware acceleration for EFA protocols and featuring application-specific runtime environments, the module requires ControlST V07.03 or later configuration software for systemic deployment.

Features

  • Dual-architecture design fusing a core UCSCH1x controller platform with a 7-port expansion sub-assembly.
  • Hardware-integrated support for EFA protocols while managing multiple concurrent communication tasks.
  • Flexible configuration profiles supporting Simplex, Dual, and Triple Modular Redundant (TMR) network topologies.
  • Integrated network services offering Modbus TCP Slave, Open Platform Communications Unified Architecture (OPC UA), and Ethernet Global Data (EGD) multi-protocol layering.
  • Convective, fanless cooling via an engineered aluminum/steel chassis with integrated vertical fins.

Applications

  • Turbine generator excitation control and automatic voltage regulation (AVR).
  • Mark VIeS safety-instrumented system (SIS) critical control and interlocking loops.
  • Plant-wide diagnostic tracking and data collection over Unit Data Highway (UDH) networks.
  • High-speed punto-a-punto point synchronous networking via High-speed Serial Link (HSSL) protocols.

Ordering Information

Module Platform Expansion I/O Ports Embedded PPNG Embedded EtherCAT EFA
UCECH1B UCSCH1x 7, RJ-45 X X

 

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE) 
Model IS420UCECH1B 
Series Mark VIe / Mark VIeS 
Module Type UCEC Controller Module 
Base Platform UCSCH1x 
Expansion Interface 7 Expansion I/O Ports (RJ-45) 
HMI / Software Requirement ControlST V07.03.000 or later 
Cooling Method Convection 
Module Dimensions (H x D x W) 168 x 150 x 85 mm (6.61 x 5.91 x 3.35 in) 
Dimensions with Mounting (H x D x W) 204 x 153 x 85 mm (8.03 x 6.02 x 3.35 in) 
Weight 2,060 g (72.7 oz) 
Operating Temperature Range -40 to 70 degC (-40 to 158 degF), ambient 25 mm (0.98 in) from module 
Storage Temperature Range -40 to 85 degC (-40 to 185 degF) 
Relative Humidity 95% non-condensing 
Normal Operating Altitude 0 to 1,000 m (0 to 3,281 ft) at 101.3 to 89.8 kPa 
Extended Operating Altitude 1,000 to 3,000 m (3,281 to 9,843 ft) at 89.8 to 69.7 kPa (Requires temperature derating to max 65 degC / 149 degF) 
Reliability (MTBF at 30 degC / 86 degF) 329,615 hours 
UCEC Module Input Power (Nominal) 28 Watts 
UCEC Module Input Power (Maximum) 42 Watts 
UCSC Controller Input Power 18 Watts (Nominal) / 30.8 Watts (Maximum) 
Input Voltage Range 18 V dc (Minimum), 24/28 V dc (Nominal), 30 V dc (Maximum) 
Input Capacitance 25 uF 
Surge Protection Non-replaceable 4 A 125 V dc rated fuse (Nominal melting: 26 A squared seconds) 
Reverse Polarity Protection Provided (Reversing +/- input will not damage the unit; will not power up) 

Connections/Interfaces

Port / Interface Label Physical Connector Type Functional Protocol / Media Specifications
Expansion Ports 1 through 7 RJ-45  High-speed Serial Link (HSSL) Interface; 10Base-TX/100Base-TX twisted pair; GE Proprietary protocol providing synchronous point-to-point communication to HSSL-enabled I/O modules.
T/SL3 RJ-45  IONet/HSSL redundant link; acts as network for TMR redundancy using all three ports. 10Base-TX/100Base-TX twisted pair.
S/SL2 RJ-45  IONet/HSSL redundant link; acts as network for Dual redundancy when paired with R/SL1. 10Base-TX/100Base-TX twisted pair.
R/SL1 RJ-45  IONet/HSSL redundant link; acts as network for Simplex redundancy configurations. 10Base-TX/100Base-TX twisted pair.
ENET 1 RJ-45  Primary Ethernet Interface to LAN (UDH). 10Base-T/100Base-TX twisted pair. Handles controller communication with ToolboxST, alarm routing to HMIs, Modbus TCP Slave, OPC UA, and EGD variable distribution.
ENET 2 RJ-45  Secondary plant network interface. 10Base-T/100Base-TX twisted pair. Supports Modbus TCP Slave, OPC UA, and/or EGD protocols. Note: Not supported for Mark VIeS control configurations.
USB1 / USB2 USB Type-A  Connection ports utilized for initial setup of the UDH IP address, configuration restorations, and physical communication link setup via ToolboxST.
uSD Micro-SD Slot  Micro-SD card storage slot (Not currently supported via system firmware).
PHY PRES Button Physical Button  Push-button mechanism pressed to initiate system restoration profiles or during the initial controller setup of the UDH IP address.
COM RJ-45 style Serial Port  Serial interface used as an alternative interface to configure the controller IP address instead of using a flash-based device.
DisplayPort DisplayPort Interface  External monitor or video adapter interface connection (Not currently supported via system firmware).
IICS Cloud Port RJ-45 Ethernet Port  Interface used to configure the EFA environment and bridge communication with the Predix cloud platform (Not supported under Mark VIeS or MarkStat control).
Energy Pack / 1-wire EEPROM Specialized Header  Energy pack interface loop allowing backup power connection to write the controller's current state to memory during unpredicted power loss (Not currently supported).

Pin Assignments (Power Plug)

Connector Pin Function Description
Pin 1 Ground Chassis safety earth connection.
Pin 2 Negative Power supply return path; the controller chassis outer case is physically bonded to power supply negative.
Pin 3 Positive Main DC power supply input line (+18 to +30 V dc).
  • Connector Model Type: Phoenix Contact MC 1,5/3-STF-3,81-1827716 
  • Supported Wire Size Range: 28 to 16 AWG 
  • Terminal Screw Torque Spec: 0.23 Nm (2 in-lb) 

Installation Guidelines

Mounting Mechanics and Torque

Directly mount the module chassis to a rigid mounting baseplate structure using four specialized mounting screws. When performing case assembly maintenance, use a Torx 8 tool and ensure all fastening points are torqued down precisely to 0.6 Nm (5.3 in-lb) to maintain outer case seal integrity.

Thermal Clearances

The module relies entirely on vertical natural convection for internal temperature regulation. It must be oriented strictly vertically with unhindered airflow passages through its cooling fins.

  • To achieve a 70 degC operating rating: Maintain an open air gap of at least 100 mm (3.94 in) directly above and below the assembly , and keep a parallel unit-to-unit spacing layout of at least 50 mm (1.97 in). Keep adjacent non-heat producing objects 25 mm (0.98 in) away from the chassis boundaries.
  • To achieve a 65 degC operating rating: The layout limits can adjust to a tight parallel unit spacing of 25 mm (0.98 in) , a bottom clear envelope of 50 mm (1.97 in) , and non-heat producing side clearances of 15 mm (0.59 in).

Electrical Input & Grounding

Cabling runs for the Phoenix power connector must remain within the 28 to 16 AWG boundary limit. Tighten terminal plug screws to a maximum value of 0.23 Nm (2 in-lb). Ensure the external electrical distribution network supplying power matches the input envelope of 18 to 30 V dc.

What happens if the power input lines are accidentally reversed during installation?

The module features integrated reverse polarity protection. Reversing the positive and negative power inputs will not damage the controller; however, the device will remain unpowered and fail to boot up.

What are the exact dimensional envelopes for this module with and without mounting accessories?

The base module dimensions are 168 x 150 x 85 mm (6.61 x 5.91 x 3.35 in). When the native mounting fixtures are attached, the total physical envelope is 204 x 153 x 85 mm (8.03 x 6.02 x 3.35 in).

Are the micro-SD slot and DisplayPort active on this module model?

No. Both the uSD micro-SD card slot and the DisplayPort hardware interfaces are present on the layout but are not currently supported by the controller firmware operating system.

What is the continuous operational lifecycle reliability rating of this controller hardware?

The module has a verified mean time between failures (MTBF) of 329,615 hours when continuously operated at a stable ambient baseline temperature of 30 degC.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской запечатанной упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашим официальным Политика возврата и возврата средств .

TECHNICAL SPECIFICATIONS

Color pattern
Серовато-белый Серебро
Country of origin
Соединённые Штаты Германия
Power source
Питается от сети переменного тока Постоянный ток (DC)

Недавно просмотренные товары

Технические знания

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий (OT), защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От клеевых систем, вдохновленных гекконами, и мягких захватов пищевого класса до инструментов на базе ИИ...

Воспоминание: как ранние электродвигатели изменили подземную добычу полезных ископаемых

От компрессоров с приводом от каната до аккумуляторных вагонеток — ранние горные работы стали поворотным моментом в индустриальной электрификации. В этой статье рассматривается, как электродвигатели...

Factory I/O: современный инструмент моделирования ПЛК для обучения промышленной автоматизации

Factory I/O меняет обучение ПЛК, предоставляя погружающие 3D промышленные симуляции для студентов, инженеров и команд технического обслуживания. Платформа сокращает разрыв между теорией и практикой...

Программирование циклов одноосевого движения на сервоприводе CMZ

В этом руководстве рассматривается, как встроенный ПЛК внутри серводрайвера CMZ SBD может выполнять автономные программы движения, включая логику поиска нуля, позиционное управление и циклическое...