Mitsubishi Electric FR-E720-5.5K FR-E700 Series Inverter

Mitsubishi Electric FR-E720-5.5K FR-E700 Series Inverter

Остался в наличии только 10 товар(ы)
  • Производитель: Mitsubishi Electric

  • Номер продукта: FR-E720-5.5K

  • Страна происхождения:Соединённые Штаты

  • Тип продукта: Variable Frequency Drives

  • Оплата: Т/Т, Western Union

  • Вес: 500г

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Engineered to deliver high-performance motor speed control in heavy industrial configurations, the Mitsubishi Electric FR-E720-5.5K is a three-phase 200V class variable frequency drive from the esteemed FR-E700 Series. Built to handle standard and heavy-duty torque demands, this 5.5 kW (7.5 HP) inverter integrates advanced magnetic flux vector control to supply reliable low-speed torque and dynamic responsiveness. It serves as a dependable control element for machinery requiring rapid acceleration, deceleration, and high-precision velocity regulation.

Features

  • High-Performance Vector Control: Advanced magnetic flux vector control algorithm delivers 150% torque at speeds as low as 1 Hz.
  • Compact Enclosure Footprint: Space-saving chassis design allows side-by-side installation to minimize control panel volume.
  • Removable Terminal Block: Simplifies wiring maintenance and reduces system downtime during hardware swap-outs.
  • Safety-Stop Functionality: Integrated dual-channel emergency stop input complies with international safety standards (EN ISO 13849-1 Category 3 / PLd).
  • USB Configuration Interface: Dedicated diagnostic port permits rapid parameter upload, download, and real-time monitoring via FR Configurator software.

Applications

  • Material Handling: High-torque conveyor systems, sorting machines, and lifters.
  • Process Machining: Variable speed control for mixers, agitators, and industrial centrifuges.
  • Fluid Management: Constant torque control of positive displacement pumps and centrifugal pumping stations.
  • HVAC Systems: Air handling unit fans, industrial blowers, and exhaust ventilation assemblies.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model / Article Number FR-E720-5.5K
Product Series FR-E700 Series
Voltage Class Three-phase 200V class (200 to 240V AC, 50/60Hz)
Inverter Capacity 5.5 kW (7.5 HP)
Recommended MCCB (No Reactor) 50 A
Recommended MCCB (With Reactor) 40 A
Magnetic Contactor (MC) S-N25
Control Logic Options Sink (NPN) or Source (PNP) selectable
Cooling Method Forced air cooling (with cooling fan)
Net Weight 4.3 kg
Shipping Weight (Calculated) 7.0 kg

Connections and Interfaces

Terminal Symbol Function Description
R/L1, S/L2, T/L3 Main power input terminals (Three-phase 200-240V AC)
U, V, W Inverter output terminals connected directly to the AC induction motor
STF / STR Forward Run / Reverse Run terminal contact command
SD Common terminal for control input contacts (Sink common)
PC Common terminal for transistor outputs and external power source (Source common)
10, 2, 5 Analog voltage input interface (0 to 10V DC speed reference)
4, 5 Analog current input interface (4 to 20mA speed reference)
A, B, C Form C relay output contact (Fault/Alarm indicator)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-E720-5.5K serves as a direct upgrade to legacy FR-E520-5.5K models. Keep in mind that control terminal dimensions and layout differ; the FR-E700 series utilizes a removable control connector card which is not physically compatible with FR-E500 backplanes. Parameter maps are highly consistent, though parameter settings for vector control (Pr. 80 and Pr. 81) must be manually reconfigured to match the motor's slip frequency and excitation current.

Application Pitfalls & Engineering Notes

During constant torque operation at frequencies below 10 Hz, standard non-ventilated AC motors can overheat rapidly. Under these conditions, specify a force-cooled motor or derate the load. Ensure the continuous ambient temperature in enclosed panels does not exceed 50 degC. If installing multiple drives side-by-side inside a single cabinet, the top shielding plates must be removed to guarantee proper airflow convection.

Commissioning & Wiring Tips

To transition the digital inputs from standard Sink logic (NPN) to Source logic (PNP), isolate the main power and toggle the physical logic selector switch located directly beneath the control circuit terminal block. When commissioning through terminal 4 (4-20mA current input), set parameter AU (Pr. 184) to activate Terminal 4 input. Run twisted, shielded-pair (STP) wiring for all analog reference cables and ground the shield only at the drive end (Terminal 5) to isolate signal lines from high-frequency common-mode noise.

Installation Guidelines

CRITICAL SAFETY WARNING

Before installing or servicing this drive, fully isolate the mains input power. Wait at least 10 minutes for the internal DC bus capacitors to discharge. Verify the DC bus voltage across terminals P/+ and N/- is below 30V DC using a certified digital multimeter. Failure to follow discharge protocols can result in severe electrical shock, personal injury, or equipment destruction.

1
Mechanical Mounting: Mount the drive vertically to a flat, non-flammable back panel using M5 screws. Maintain at least 50mm clearance on both sides and 100mm clearance above and below the unit for heat dissipation.
2
Main Power Wiring: Connect three-phase 200V supply conductors to terminals R/L1, S/L2, and T/L3 via the recommended 50A MCCB. Connect the motor leads to U, V, and W. Ensure the protective earth (PE) terminal is securely grounded using a low-impedance copper conductor.
3
Control Circuit Integration: Wire standard start/stop signals to the STF/STR inputs. If external analog controls are required, connect the input references to terminal 2 or 4. Check the position of the Sink/Source jumper switch to match external PLC I/O configurations.
4
Initial Power-Up and Calibration: Energize the unit and set motor nameplate data, including rated voltage, current, and frequency. Execute an off-line auto-tuning sequence (Pr. 96) to optimize the internal motor flux model for efficient and stable dynamic performance.
Loading product navigation…

What is the recommended breaker size for the FR-E720-5.5K?

A 50 A molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELB) is recommended without a reactor connection. If an AC or DC reactor is connected to improve power factor, a 40 A breaker should be used.

Does this model support Modbus RTU communications?

Yes, the drive features built-in Modbus RTU communication capabilities through the integrated RS-485 RJ45 interface on the front panel, supporting terminal network control without requiring additional interface cards.

What is the physical weight of this VFD?

The net weight of the device is 4.3 kg (9.48 lbs). Packaged and configured for dispatch, the estimated shipping weight is approximately 7.0 kg (15.4 lbs).

Can I configure the digital control terminals to PNP logic?

Yes. The control circuit logic can be toggled between Sink (NPN, negative common) and Source (PNP, positive common) using a sliding select switch located beneath the control circuit terminal block.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Соединённые Штаты

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...