1 из 1

Omron CJ1W-OD213 CJ Series 16-Point Sinking Transistor Output Module

Omron CJ1W-OD213 CJ Series 16-Point Sinking Transistor Output Module

Остался в наличии только 6 товар(ы)
  • Производитель: Omron

  • Номер продукта: CJ1W-OD213

  • Страна происхождения:Япония

  • Тип продукта: PLC Output Modules

  • Оплата: Т/Т, Western Union

  • Вес: 1200г

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Executing high-speed switching operations across complex control networks, the Omron CJ1W-OD213 functions as a reliable sinking transistor output module within the CJ-series PLC architecture. This module provides 16 discrete sinking output points on a single common terminal circuit, engineered specifically to handle precision high-frequency switching tasks with an ultra-fast response envelope of 15 microseconds for ON transitions and 80 microseconds for OFF transitions. Its space-saving design integrates directly onto the standard CJ-series backplane and features a detachable terminal block to simplify field wiring and routine maintenance without disturbing system connections.

Features

  • High-Speed Switching: Outstanding transient response times (15 us ON max, 80 us OFF max) optimize its performance in fast-cycle machine control.
  • Efficient Channel Density: 16 sinking transistor outputs grouped into a single circuit to minimize module footprint on the chassis.
  • Robust Load Capacity: Supports individual loads of up to 0.5 A per point while maintaining a combined unit capacity of up to 5.0 A.
  • Detachable Terminal Block: Enables pre-wiring and swap-out of module electronics without disconnecting external field wires.
  • Clear Diagnostic Indicators: Front-facing LED status lights show the active operational status of each individual output point.

Applications

  • Solenoid Valve Control: Driving low-power pneumatic and hydraulic directional valves on automated production lines.
  • Packaging Machinery: Operating indexing mechanisms, pushers, and high-speed labeling heads.
  • Semiconductor Processing: Controlling auxiliary material handling, cleaning cycles, and transfer systems.
  • Discrete Assembly Systems: Managing light curtains, tower lights, small relays, and electronic actuators.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Number CJ1W-OD213
Module Type Transistor Output Unit (Sinking Outputs)
Number of Output Points 16 points (16 points/common, 1 circuit)
Rated Load Voltage 24 VDC
Operating Load Voltage Range 20.4 to 26.4 VDC
Maximum Load Current 0.5 A per point, 5.0 A per unit
Maximum Inrush Current 4.0 A per point, 10 ms maximum
Leakage Current 0.1 mA maximum
Residual Voltage 1.5 V maximum
ON Response Time 15 microseconds maximum
OFF Response Time 80 microseconds maximum
Insulation Resistance 20 MOhm minimum between external terminals and GR terminal (at 100 VDC)
Dielectric Strength 1,000 VAC between external terminals and GR terminal for 1 minute (leakage current: 10 mA max)
Internal Current Consumption 150 mA maximum at 5 VDC
External Power Supply Requirements 20.4 to 26.4 VDC, 55 mA minimum
Fuses None (external fusing recommended)
Module Net Weight 110 g maximum
Shipping Weight (Calculated) 1.2 kg

Connections and Interfaces

This sinking output module relies on an external 24 VDC power source to switch the field loads. Ensure proper polarity is observed during terminal wiring to prevent circuit damage.

Terminal Point Signal Function Wiring Detail
0 to 15 Output Channels 00 to 15 Connect to individual load negative sides (sinking load path)
COM Sinking Output Common Connected to the 0 VDC side of the external load supply
+V External Power Supply Input (+V) Connect to +24 VDC side of the external load supply (required for internal drive logic)

Empirical Engineering Insights

Alternative Models & Compatibility

When updating legacy machinery, note that this module uses a detachable M3 screw terminal block for connection. It is often evaluated as a modular alternative to high-density models like the CJ1W-OD231, which uses a 40-pin connector layout. Moving from connector-style modules to terminal-block units requires verifying the physical enclosure wireways and spacing constraints.

Application Pitfalls & Engineering Notes

Because this module is designed without built-in internal fuses, any high-current short on an output channel will permanently destroy the associated output transistor. It is critical to incorporate fast-acting external fuses in series with the load supply line to safeguard the internal backplane circuitry. Furthermore, while individual channels support 0.5 A, the aggregate current limit of 5.0 A must not be exceeded under continuous operation across all active channels.

Commissioning & Wiring Tips

Always implement inductive surge suppression diodes in parallel with inductive loads, such as relay coils or solenoid valves. Transistor outputs are highly sensitive to back-EMF spikes generated upon de-energizing inductive loads; failing to install snubber diodes close to the load can lead to pre-mature channel failure or intermittent backplane communication resets.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all power sources (both the main PLC system and external output load supplies) before mounting, dismounting, or servicing terminal connections. Failure to remove external power before working on the module can result in equipment damage, accidental actuator activation, or electrical shock.

1

Hook the top bracket of the module onto the slot of the CJ-series backplane and pivot the module securely into position until it snaps flush with the bus connection.

2

Tighten the upper and lower mounting screws to lock the physical module firmly to the backplane, ensuring proper chassis grounding and resistance to vibration.

3

Wire the field devices to the detached terminal block according to the sinking output electrical schematic, and secure the +24 VDC external drive voltage lines.

4

Align and press the completed terminal block firmly into the module until the locking tabs snap shut, verifying clear LED visualization pathways.

Loading product navigation…

Does this transistor output module have built-in short-circuit protection?

No, this module does not feature internal fusing. External fuses must be installed on the load circuits to protect the internal transistors from overcurrent conditions.

What is the aggregate current limit for this 16-point unit?

The module allows a maximum of 0.5 A per point, but the combined load current for all 16 channels must not exceed 5.0 A simultaneously.

How should inductive loads be handled with these sinking outputs?

When switching inductive loads like solenoids or relays, install an external flyback diode across each load to prevent high-voltage spikes from degrading the output transistors.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...