Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Omron NS5-TQ10B-ECV2 NS-Series Programmable Terminal

Остался в наличии только 5 товар(ы)
  • Производитель: Omron

  • Номер продукта: NS5-TQ10B-ECV2

  • Страна происхождения:Япония

  • Тип продукта: HMI Operator Terminals

  • Оплата: Т/Т, Western Union

  • Вес: 8000г

  • Размеры: 245 x 195 x 110 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

Engineered for distributed machine-level monitoring, the Omron NS5-TQ10B-ECV2 serves as a centralized operator control interface within the premium NS-Series platform. This hardware terminal combines a vibrant 5.7-inch High-Luminance TFT Color LCD with robust communication capabilities, incorporating an integrated 10Base-T Ethernet port and dual serial transceivers. Operating on a standard 24 VDC input, the terminal is designed to withstand harsh factory environments, featuring an IP65f front-face rating and a resilient black protective bezel. With 60 MB of internal memory, it supports complex graphic representations, high-density alarm logging, and seamless CX-Designer configuration integration.

Features

  • High-visibility TFT display supporting up to 32,768 colors for realistic CAD-based machine graphics.
  • Built-in Ethernet port enabling FTP server capabilities, data transfers, and remote monitoring over TCP/IP.
  • Dual independent RS-232C serial ports for direct, simultaneous connections to PLCs, temperature controllers, and barcode readers.
  • Extensive 60 MB memory allocation for substantial screen data storage, system recipes, and historic trend logs.
  • High-durability LED backlight providing long-term illumination consistency without the degradation risks of legacy CCFL lamps.

Applications

  • Automated packaging and cartoning machinery line integration.
  • Pumping stations and local water treatment HMI monitoring panels.
  • Automotive component assembly verification and testing cells.
  • Discrete material handling and sorting system visualization.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Number NS5-TQ10B-ECV2
Display Type 5.7-inch High-Luminance TFT Color LCD
Resolution 320 x 240 pixels (QVGA)
Backlight LED (non-replaceable, service life approx. 50,000 hours)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 W maximum
Onboard Ethernet 1x RJ-45 Port (10Base-T)
Serial Communications 2x RS-232C Ports (D-sub 9-pin female)
USB Interfaces 1x USB Type B Slave (for programming download)
Internal Project Memory 60 MB Flash Memory
Enclosure Bezel Color Black
Protection Rating IP65f (front panel, panel-mounted)
Operating Temperature 0 to 50 degC
Shipping Weight (Calculated) 1.85 kg
Package Dimensions (Calculated) 245 x 195 x 110 mm

Connections and Interfaces

Port / Terminal Block Physical Form Signal Assignment & Pin Function
Serial Port A (CN1) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 1
Serial Port B (CN2) D-sub 9-pin Female Host Link / NT Link RS-232C communication channel 2
Ethernet RJ-45 10Base-T network interface (FTP, screen data transfer, FINS communications)
USB (Slave) USB Type B Connection to CX-Designer programming PC for screen development and diagnostics
Power Input M3 Screw Terminals Pin 1: +24 VDC | Pin 2: 0 VDC | Pin 3: Functional Ground (FG)

Empirical Engineering Insights

Alternative Models & Compatibility

The "ECV2" revision represents a major evolutionary step over older NS5-TQ10B-V2 units. The critical distinction lies in the backlight design: the ECV2 employs an integrated solid-state LED configuration, whereas earlier legacy units utilized CCFL tubes driven by high-voltage internal inverters. Project databases generated for older NS5 versions can be converted to run on the ECV2 unit via CX-Designer; simply update the destination hardware designation inside the system properties before transferring. Be aware that color rendering profiles may differ slightly due to the shift from CCFL to LED emission spectrums.

Application Pitfalls & Engineering Notes

Touch-screen matrix degradation is a common physical failure point if these terminals are installed in close proximity to radiant heat sources. While the unit functions up to 50 degC, prolonged internal temperatures exceeding 45 degC inside non-ventilated enclosures can lead to local delamination of the resistive overlay. For panels where ambient internal heat is a constant factor, we recommend installing low-draw convective air systems or cooling fans, maintaining a mandatory 100 mm clearing around the backplate air vents.

Commissioning & Wiring Tips

To prevent grounding-loop failures across serial pathways, ensure the functional ground terminal (FG) is tied back to the main cabinet star-ground point via a heavy-gauge (minimum 2 mm²) stranded green wire. When implementing RS-232C communication lines to CS/CJ-series PLCs, always utilize double-shielded twisted pairs and ground the cable shield on the PLC chassis side only. This layout successfully diverts high-frequency industrial noise away from the NS5 transceiver chips, avoiding intermittent "HMI Communication Timeouts" errors.

Installation Guidelines

CRITICAL WARNING: Isolate the 24 VDC supply and de-energize the entire control panel prior to attempting HMI physical mounting or electrical termination. Executing wiring procedures while power is active can induce voltage spikes, causing permanent logic board destruction.
1
Ensure the panel cutout dimensions measure exactly 184.0 mm (+0.5/-0 mm) wide by 131.0 mm (+0.5/-0 mm) high to achieve an optimal environmental seal.
2
Check that the waterproof rubber sealing gasket is seated uniformly in the front-bezel groove before inserting the HMI terminal into the cutout.
3
Secure the unit into the panel using the provided metal mounting clamps. Tighten the clamping screws evenly to a target torque of 0.5 to 0.6 N-m; over-torqueing may warp the plastic bezel, ruining the IP65f seal.
4
Terminate the 24 VDC lines to the power terminal block, verifying polarity matches the marked terminals before switching on the power.
Loading product navigation…

What is the primary technical difference between the ECV2 and the standard V2 NS5 models?

The ECV2 model incorporates an integrated LED backlight and built-in 10Base-T Ethernet, replacing the CCFL backlights used in standard V2 units, which reduces thermal output and increases operational lifespan.

Does this operator terminal support expansion communication boards?

Yes, the NS5 features a backplate expansion slot that allows the installation of Controller Link or other option boards to integrate with existing network architectures.

Can I download projects to the NS5 terminal without using the USB port?

Yes, screen projects can be transferred directly over the network using the built-in Ethernet interface, or physically using a standard Memory Card in the integrated slot.

What software package is required to configure the screen graphics for this HMI?

Omron CX-Designer, which is part of the comprehensive CX-One software suite, is the native utility used to configure and program the NS-Series terminals.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Недавно просмотренные товары

Технические знания

Электрические приводы, разработанные для замены гидравлических систем: практическое руководство по промышленной автоматизации

В этой статье объясняется, как интегрированные электрические приводы, такие как серия e-Actuator от SMC, преобразуют промышленное управление движением, заменяя традиционные пневматические и...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...