1 из 3

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Остался в наличии только 8 товар(ы)
  • Производитель: Yokogawa

  • Номер продукта: SAI143-S33

  • Страна происхождения:Япония

  • Тип продукта: Analog Input Module

  • Штрихкод: 8537101190

  • Оплата: Т/Т, Western Union

  • Вес: 340г

  • Размеры: 32.8 mm x 130 mm x 107.5 mm

  • Порт отправления: Сямынь

  • Гарантия: 12 месяцев

Количество
Просмотреть полные детали

Description

The Yokogawa SAI143-S33 is a high-reliability current input module designed for mounting on the safety node unit and safety control unit within the ProSafe-RS safety instrumented system. This module plays a critical role in safety functions by inputting 4 to 20 mA signals from field instruments directly into the Safety Control Station (SCS). It supports dual-redundant configurations to achieve enhanced system availability and fault tolerance. The SAI143-S33 features standard individual channel configuration pins for 2-wire or 4-wire transmitters and provides module isolation for its 16 processing channels.

Features

  • Dual Redundancy: Supports full dual-redundant configuration to eliminate single points of failure in safety-critical applications.
  • Flexible Sensor Hookup: Individual channel setting via pins to accommodate both 2-wire and 4-wire field transmitter arrangements.
  • Simultaneous Power Management: Built-in transmitter power supply ON/OFF function across all 16 channels simultaneously, facilitating alarm resets for Fire and Gas devices.
  • Robust Isolation: Delivers module-level galvanic isolation protecting internal system electronics from hazardous field transients.

Applications

  • Safety Instrumented Systems (SIS) 
  • Emergency Shutdown Systems (ESD)
  • Fire and Gas (F&G) System integration and device resetting 
  • Process industry safety monitoring and critical current loop sourcing 

Ordering Information

Model Suffix Codes Description
SAI143   Analog Input Module (4 to 20 mA, 16 channels, module isolation) 
  -S Standard type 
  3 For pressure clamp terminal block or MIL cable with no explosion protection
3 With ISA Standard G3 and temperature (-20 to 70 degC) 

Technical Specifications

Item Specifications
Manufacturer Yokogawa Electric Corporation 
Model SAI143-S33 
Number of Input Channels 16 channels, module isolation 
Rated Input Range 4 to 20 mA 
Permissible Input Range 0 to 25 mA 
Input Impedance (Power-ON) 250 Ohm + Voltage drop in the input protection circuit inside the module / Current value 
Input Impedance (Power-OFF) 500 Ohm minimum 
Maximum Voltage Drop 0.45 V (in the input protection circuit) 
Rated Accuracy ±16 uA (Input range 1 to 23 mA for Style S3) 
Data Update Frequency 40 ms 
Temperature Drift ±16 uA/10 degC 
Transmitter Power Supply 16.15 V minimum (at 20 mA), 26.4 V maximum (at 0 mA) 
Output Current Limit 25 mA 
Withstand Voltage 1.5 kV AC between input signal and system for 1 minute 
Maximum Current Consumption 5 V system: 320 mA, 24 V system: 550 mA 
Ambient Temperature -20 to 70 degC 
Environmental Code ISA Standard G3 
Weight Approx. 0.34 kg (For pressure clamp terminal block or MIL cable) 
Dimensions (W x H x D) 32.8 mm x 130 mm x 107.5 mm (For pressure clamp and MIL cable) 

Installation Guidelines

  • Module Siting: Mount the current input module onto a compatible safety node unit or safety control unit chassis.
  • Redundancy Setup: When implementing dual-redundant pairs, order an additional tracking module with identical technical specifications but without specific optional suffix accessories.
  • Safety Isolation Barriers: Do not connect Zener barriers directly to this hardware. Utilize an approved isolation barrier when deploying an intrinsically safe instrumented loop.
  • False Insertion Prevention: When deploying option /PRP, utilize the specified matching field signaling cable variant equipped with the corresponding option /SAI143 to ensure functional physical key alignment.

Compliance and Certifications

  • ISA Standard G3: Certified for installation within corrosive industrial environments meeting the G3 severity specifications.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa SAI143-S33 ProSafe-RS Analog Input Module

Can Zener barriers be connected directly to the module?

No, Zener barriers cannot be connected to this module. An isolation barrier must be used when an intrinsically safe instrumented system is required.

What is the purpose of the transmitter power supply ON/OFF function?

This function allows the module to turn off the transmitter power supplied to all 16 channels simultaneously under a 2-wire setting, which enables resetting the alarm state of Fire and Gas devices.

How is the 2-wire or 4-wire mode configured on the module?

The 2-wire or 4-wire operational mode is set individually for each channel using dedicated physical setting pins on the module.

Глобальная экспресс-доставка

  • Стандартная доставка: 4-6 рабочих дней через DHL, FedEx и UPS.
  • Экспресс-отправка: Отправка в тот же день для заказов со склада, сделанных до 14:00 (GMT+8).
  • Мировое покрытие: Обслуживаем более 150 стран, включая быструю доставку в Саудовскую Аравию и ОАЭ.

Возвраты и гарантия

  • 30-дневная гарантия: Принимаются возвраты товаров со склада в оригинальной, заводской упаковке.
  • 12-месячная гарантия: Каждый промышленный компонент поддерживается нашей профессиональной технической гарантией.

Заказы обрабатываются и доставляются с понедельника по пятницу (кроме государственных праздников).


Для полной информации о праве на возврат, сборах за пополнение запасов и международных возвратах, пожалуйста, ознакомьтесь с нашей официальной Политика возврата и возмещения .

TECHNICAL SPECIFICATIONS

Country of origin
Япония

Недавно просмотренные товары

Технические знания

Электрические приводы для замены жидкостей: практическое руководство

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Математические операции с использованием OpenPLC для промышленных автоматизированных систем

В этой статье объясняется, как системы ПЛК выполняют основные математические операции, такие как сложение, вычитание, умножение, деление, взятие остатка и возведение в степень в рамках промышленной...

Продвинутая булева логика в программировании ПЛК с использованием FBD: практические промышленные применения за пределами базовой логики

В статье объясняются несколько продвинутых функций булевой логики, используемых в программировании ПЛК, помимо базовых операций AND, OR и NOT. Рассматривается, как такие инструменты, как таблицы...

Булева логика в программировании ПЛК: понимание логических элементов FBD

Булева логика является основой каждой программы ПЛК. От простого управления машинами до сложных систем промышленной автоматизации, логические элементы определяют, как контроллеры реагируют на...

Подробное руководство по промышленным файрволам и сегментации сетей ОТ

Промышленные межсетевые экраны играют ключевую роль в кибербезопасности операционных технологий, защищая сети ПЛК, ДСК и SCADA посредством сегментации, контроля входящего и исходящего трафика, а...

Руководство по роботизированным захватам: от деликатного обращения до тяжелой автоматизации

Современные роботизированные захваты развиваются дальше традиционных механических челюстей. От систем с клеящими поверхностями, вдохновлёнными гекконами, и мягких захватов пищевого класса до...