1 จาก 6

ABB 1SVR427026R0000 CP-C 24/20.0 Power Supply Module

ABB 1SVR427026R0000 CP-C 24/20.0 Power Supply Module

Only 3 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 1SVR427026R0000

  • Country of origin:สวีเดน

  • Product Type: DIN Rail Power Supplies

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 1570g

  • Dimensions: 82 mm x 129.4 mm x 136 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

This primary switch-mode power supply is designed to provide regulated DC power for heavy-duty industrial control and automation architecture. The ABB CP-C.1 24/20.0 (Product ID: 1SVR360763R1001) delivers a stable 24 V DC output at 20 A from a versatile single-phase input grid. Engineered with a built-in power reserve of up to 30%, this power supply module effectively accommodates high transient starter currents and fluctuating dynamic loads without disrupting overall system operation. This device integrates smoothly with standard PLC and DCS automation networks requiring continuous duty cycles and precise voltage stability.

Features

  • High-efficiency primary switch-mode design 
  • Wide input voltage range accepting 85-264 V AC and 90-300 V DC 
  • Continuous rated output power of 480 W 
  • U/I output characteristic curve featuring a power reserve up to 30% 
  • Adjustable output voltage range from 22.5 to 28.5 V DC 
  • Active power factor correction complying with EN 61000-3-2 
  • Support for parallel operation to safely extend total capacity or establish a redundant system layout 

Applications

  • Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC) power cabinets 
  • Factory machine automation and critical control loops
  • Power infrastructure for manufacturing plant automation instrumentation

Technical Specifications

Parameter Specification
Manufacturer ABB 
Model Designation CP-C.1 24/20.0 
Product ID 1SVR360763R1001 
EAN 4013614503832 
Function Switch mode power supply 
Number of Phases 1-phase 
Rated Input Voltage (Uin) 100 - 240 V AC / 100... 270 V DC 
Input Voltage Range (Uin boundaries) 85... 264 V AC / 90... 300 V DC 
Typical Input Current 4.6 A at 115 V AC / 2.3 A at 230 V AC 
Rated Frequency (f) 50/60 Hz 
Rated Frequency Limits 45... 65 Hz 
Hold-up Time min. 40 ms at 230 V AC 
Rated Output Power 480 W 
Rated Output Voltage 24 V DC 
Output Voltage Adjustment Range 22.5 ... 28.5 V DC 
Rated Output Current 20 A (at -25 Celsius ... +60 Celsius) / 26 A (at -25 Celsius ... +40 Celsius) 
Output Characteristic U/I characteristic curve with power reserve 
Rated Insulation Voltage (Ui)

Input Circuit / Output Circuit: 300 V


 

Input Circuit / PE: 300 V


 

Input Circuit / Relay Contact: 300 V


 

Output Circuit / PE: 50 V 

Rated Impulse Withstand Voltage (Uimp)

Input Circuit/Output Circuit: 4 kV


 

Input Circuit/PE: 4 kV


 

Input Circuit / Relay Contact: 4 kV


 

Output Circuit / PE: 0.5 kV


 

Output Circuit: 0.5 kV 

Degree of Protection Housing: IP20 / Terminals: IP20 
Pollution Degree
Tightening Torque Input Circuit: 0.5 N-m / Output Circuit: 1.2 N-m / Auxiliary Circuit: 0.5 N-m 
Wire Stripping Length Input Circuit: 8 mm / Output Circuit: 10 mm / Auxiliary Circuit: 8 mm 
Product Net Width 82 mm 
Product Net Height 129.4 mm 
Product Net Depth / Length 136 mm 
Product Net Weight 1.57 kg 
Ambient Air Temperature

Operation: -25 ... +70 Celsius


 

Storage: -40 ... +85 Celsius 

Maximum Operating Altitude Permissible 5000 m 

Connections/Interfaces

Terminal Connection Type Wire Size Connecting Capacity
Connecting Capacity Input Circuit

Flexible with Ferrule: 0.5... 2.5 mm²


 

Flexible: 0.5 ... 2.5 mm²


 

Rigid: 0.5 ... 4 mm² 

Connecting Capacity Output Circuit

Flexible with Ferrule: 2.5... 10 mm²


 

Flexible: 2.5... 10 mm²


 

Rigid: 2.5... 16 mm² 

Connecting Capacity Input Circuit UL/CSA

Flexible/Flexible with Ferrule: 20-12 AWG


 

Rigid: 20-10 AWG 

Connecting Capacity Output Circuit UL/CSA

Flexible: 12-8 AWG


 

Rigid: 12-6 AWG 

Installation Guidelines

DIN Rail Mounting

Install onto standard 35 mm mounting rails (TH35-15 or TH35-7.5) in accordance with IEC 60715. Snap the module firmly into place using mounting positions 1 through 7 to guarantee stability under mechanical vibration.

Minimum Mounting Clearances

To maintain adequate vertical air circulation and minimize physical thermal load transfers, leave a minimum clearance of 25 mm horizontally and vertically from any adjacent electrically conductive board or equivalent equipment of the same unit type.

Wire Termination Requirements

Ensure input connections conform to a tightening torque of 0.5 N-m (4.4 in-lb). Output connections must be tightened securely to 1.2 N-m (10.5 in-lb) to minimize contact resistance and overheating at higher current thresholds.

Compliance and Certifications

  • CAN/CSA C22.2 No.107.1 
  • IEC/EN 63000, IEC/EN 61000-6-2, IEC/EN 61000-6-3, IEC/EN 61204, IEC/EN 61010-1 
  • UL 508, UL 61010-1, UL 61010-2-201 
  • ABS (ABS_17-HG1591548-2-PDA) 
  • CB Scheme (CB_DK_103862_A2_UL) 
  • cULus (cULus508_20161102-E174460) 
  • cURus (CURus60950 E196145-A11-UL / CURUSANSI12-12_20161122_E317914-) 
  • CE (1SVD982010-00) 
  • UKCA (1SVD982010-10) 
  • DNV GL (DNV_GL_TAA00000YB_1) 
  • SEMI F47 (SEMI_F47 4787681819-2) 

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB 1SVR427026R0000 CP-C 24/20.0 Power Supply Module

Can the 1SVR427026R0000 handle inductive and high-inrush startup loads?

Yes. This power supply features an integrated 10 percent continuous power reserve, enabling it to deliver up to 22 A instead of the nominal 20 A at temperatures below 40 degC to easily manage short-duration high-inrush loads.

What is the recommended ventilation clearance for the CP-C 24/20.0?

To maintain optimal natural convection cooling, a vertical clearance of at least 80 mm is required on both top and bottom, and a horizontal clearance of 10 mm from other active DIN rail equipment.

Can I configure multiple 1SVR427026R0000 units in redundant parallel operation?

Yes. Multiple units can be operated in parallel. For strict N+1 redundant operation, it is recommended to integrate the external CP-C CO redundancy unit block.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สวีเดน

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...