1 จาก 3

ABB TB820V2 3BSE013208R1 S800 I/O Modulebus Cluster Modem

ABB TB820V2 3BSE013208R1 S800 I/O Modulebus Cluster Modem

Only 4 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: 3BSE013208R1

  • Country of origin:สวิตเซอร์แลนด์

  • Product Type: Modulebus Cluster Modem

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 58 mm x 170 mm x 122 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

The TB820V2 with part number 3BSE013208R1 is an optical cluster modem designed for non-redundant communication operations within the S800 I/O system framework. It functions as a specialized interface for the reception, conversion, transmission, and regeneration of data signals across local or wide area industrial networks. The module establishes secure, fiber-optic links between distributed S800 I/O clusters and central controllers, ensuring noise-immune data transfer in harsh environments. Each unit comes packaged with a dedicated power supply connector and a TB807 Modulebus Terminator to ensure correct electrical termination of the local bus cluster.

Ordering Information

  • TB820V2
    • 3BSE013208R1: Modulebus Cluster Modem (Non-redundant operation)

Hardware Specifications

Parameter Specification
Manufacturer ABB
Model / Type Designation TB820V2
Product ID / Part Number 3BSE013208R1
Module Type Modulebus Cluster Modem
System Compatibility S800 I/O, System 800xA (Versions 4.0, 4.1, 5.0, 5.1, 6.0), Advant OCS with Master SW, Advant OCS with MOD 300 SW, Compact Product Suite
Network Operation Non-redundant
Included Components 1 x Power Supply Connector, 1 x TB807 Modulebus Terminator
Customs Tariff Number 85176200
Number of Batteries 0
Product Net Width 58 mm
Product Net Height 170 mm
Product Net Depth / Length 122 mm
Product Net Weight 0.3 kg
RoHS Compliance Following EU Directive 2011/65/EU
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

Engineering Notes

  • System Architecture Integration: The cluster modem operates within the local Modulebus hierarchy to bridge communication between external controller racks and distributed S800 remote I/O blocks.
  • Termination Requirement: Correct bus topology requires the installation of the included TB807 Modulebus Terminator at the physical end of the localized cluster segment to suppress signal reflections.
  • Non-Redundant Configuration: This hardware variant is optimized strictly for simplex (non-redundant) communication lines; dual-line pathing architectures require alternative module selections.
  • Broad Platform Compatibility: Fully verified for cross-generational deployment, bridging legacy Advant Fieldbus 100 systems with modern System 800xA control configurations.

Field Guidelines

  • Module Assembly: Mount the unit onto its designated backplane slot within the I/O chassis, securing any mechanical lock latches to ensure solid alignment with the backplane communication rail.
  • Power Connection: Use only the provided power supply connector block to land the required operational voltages, ensuring correct polarity before energizing the circuit.
  • Fiber Optic Handling: Avoid sharp bends or pulling stresses on the optical patch cables connected to the modem interface, as excessive attenuation or physical breakage can degrade cyclic data exchange.
  • Electrostatic Discharge Precautions: Adhere to strict industrial ESD measures, including wearing an approved grounding wrist strap, when handling the modem or installing the terminating plug.

Technical & Procurement FAQ

Q: What physical accessories are included standard in the box with this model?

A: Every unit ships complete with one power supply connector and one TB807 Modulebus Terminator block.

Q: Can this specific module designation be deployed in a redundant network communication layout?

A: No, this unit is engineered and specified strictly for non-redundant network configurations.

Q: Does this hardware module require any internal backup batteries for configuration retention?

A: No, the module operates with zero internal batteries, running completely on external system backplane power.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB TB820V2 3BSE013208R1 S800 I/O Modulebus Cluster Modem

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาว สีขาวอมเทา
Country of origin
สวิตเซอร์แลนด์
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...