1 จาก 3

Allen-Bradley 1756-OV16E ControlLogix Fused Sinking Output Module

Allen-Bradley 1756-OV16E ControlLogix Fused Sinking Output Module

Only 5 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-OV16E

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Fused Sinking Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 280g

  • Dimensions: 145 mm x 35 mm x 130 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The Allen-Bradley 1756-OV16E is a 16-point digital DC output module designed for use within the ControlLogix chassis system. Operating within a 10 to 30V DC range, this sinking current output module provides individual electronic fusing per point to ensure robust circuit protection. It utilizes a Coordinated System Time (CST) Timestamped Fuse Data—Output Data communication format, enabling the module to transmit a Fuse Blown status along with the exact system clock value from the local chassis whenever a fuse blows or resets. This diagnostic capability allows for precise fault tracking and rapid troubleshooting in critical process control applications.

Features

  • 16-Point Sinking Outputs: Provides 16 distinct sinking current digital outputs operating between 10...30V DC.
  • Per-Point Electronic Fusing: Individual electronic fuse protection across all 16 channels to isolate faults and protect field-side wiring.
  • Scheduled Outputs: Offers output synchronization referenced to the Coordinated System Time (CST) with a maximum synchronization variance of 16.7 seconds.
  • Configurable Fault States: Each point can be independently configured to hold its last state, turn on, or turn off (default) during a fault condition.
  • Program Mode Configuration: Configurable states per point during Program mode, supporting hold last state, on, or off (default).
  • Advanced Diagnostics: Returns real-time Fuse Blown status accompanied by local chassis system clock timestamps for both fuse blow and reset events.

Applications

  • Solenoide valve control in automated assembly lines.
  • Pilot light and indicator panel management.
  • Interfacing with DC inputs of secondary control devices or motor drives.
  • General-purpose low-side (sinking) switching applications in discrete manufacturing.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model 1756-OV16E
Product Type Sinking Current Output Module
Number of Outputs 16
Operating Voltage Range 10...30V DC
Fusing Electronically fused per point
Communication Format CST Timestamped Fuse Data—Output Data
Scheduled Outputs Synchronization 16.7 seconds maximum reference to CST
Fault States Per Point Hold last state, On, Off (default)
Program Mode States Per Point Hold last state, On, Off (default)
Country of Origin United States / USA
Weight 0.28 kg
Dimensions 145 mm x 35 mm x 130 mm

Installation Guidelines

DIN Rail and Chassis Installation

  • Ensure the ControlLogix chassis power supply is switched off before inserting or removing the module.
  • Align the circuit board of the module with the top and bottom chassis guides in the designated slot.
  • Slide the module into the chassis until the top and bottom locking tabs click into place securely.

Wiring and Polarity

  • Verify all field-side power is disconnected before working on the terminal blocks.
  • Connect the common positive rail (+V DC) to the field load, and route the return path through the module's sinking output terminals to the negative DC reference.
  • Maintain proper separation between low-voltage DC signals and high-voltage AC power lines within the enclosure wire ducts to prevent electromagnetic interference.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1756-OV16E ControlLogix Fused Sinking Output Module

How does the module communicate a fuse failure back to the controller?

The module uses the CST Timestamped Fuse Data communication format. When a fuse blows or is reset, it returns a Fuse Blown status along with the precise system clock value from the local chassis.

What is the default state of an output point if the controller enters Program mode?

The default state for each output point in Program mode is Off, though it can be user-configured to Hold Last State or turn On.

What does the scheduled outputs feature provide on this module?

It provides output synchronization referenced to the Coordinated System Time with a maximum synchronization timing of 16.7 seconds.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา สีดำ
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...