1 จาก 3

Allen-Bradley 1783-ETAP2F Stratix EtherNet/IP Tap

Allen-Bradley 1783-ETAP2F Stratix EtherNet/IP Tap

Only 2 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1783-ETAP2F

  • Country of origin:สหรัฐอเมริกา

  • Product Type: 1+2 Port EtherNet/IP Taps

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 260g

  • Dimensions: 132 mm x 48 mm x 105 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The Allen-Bradley 1783-ETAP2F is a 3-port industrial network interface component engineered to provide flexible connectivity options inside an EtherNet/IP network deployment. This specialized EtherNet/IP Tap features one local copper port paired with two fiber optic ports to facilitate the integration of single-port field devices into linear, star, or high-availability Device-Level Ring (DLR) communication networks. By combining copper and fiber connections, the module helps extend network media segments across greater plant distances while simultaneously protecting critical processing loops from external electromagnetic interference. The device seamlessly interfaces with industrial automation equipment, programmable controllers, and distributed I/O nodes to maintain reliable data transmission pathways and optimize plant uptime.

Features

  • Equipped with 1 local copper RJ45 port supporting 10/100 Mbps autosensing data transfer rates.
  • Features 2 multimode fiber optic LC ports designed for reliable 100 Mbps transmission loops.
  • Supports high-availability industrial network structures including linear links and Device-Level Ring (DLR) topologies.
  • Housed inside a compact, rugged IP20 rated enclosure optimized for space-restricted industrial enclosures.
  • Operates on a standard 24V DC input supply path with low power consumption.

Applications

  • Device-Level Ring (DLR) machinery segments requiring reliable network loop fault tolerance.
  • Long-distance industrial networking runs that require the noise isolation advantages of fiber optic media.
  • Distributed controller and field device integration over mixed-media communication backbones.

Technical Specifications

Attribute Specification
Manufacturer Allen-Bradley
Catalog Number 1783-ETAP2F
Product Type EtherNet/IP Tap
Product Series Stratix
Copper Interfaces 1 RJ45 Port (10/100 Mbps)
Fiber Interfaces 2 LC Multimode Ports (100 Mbps, 100Base-FX)
Power Supply 24V DC (20.4...27.6V DC, Class 2)
Current Rating 260 mA
Power Consumption 4.8W
Enclosure Type IP20
Operating Temperature -25...60 Celsius (-13...140 Fahrenheit)
Network Media Male RJ45 to Male RJ45 Patchcord, Unshielded Twisted Pair, Teal TPE Cable, 1.9 m
Recommended Cable Class Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 242

 

Installation Guidelines

  • Install the tap hardware firmly onto a clean, symmetrical top-hat DIN rail within a protective industrial control enclosure.
  • Connect a regulated 24V DC external power loop to the designated input terminal block, adhering strictly to Class 2 power supply constraints.
  • Terminate local network connections by running high-quality unshielded twisted-pair (UTP) Category 5e copper patchcords to the RJ45 port.
  • Establish long-distance trunk connections by plugging multimode fiber cables equipped with proper LC connectors directly into the twin fiber ports.
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1783-ETAP2F Stratix EtherNet/IP Tap

What is the primary function of the device in an industrial control topology?

The device acts as a three-port media tap that connects individual industrial automation components with single Ethernet interfaces directly into linear or fault-tolerant Device-Level Ring networks.

What connection physical configurations are provided on the unit interface?

The unit is outfitted with one copper RJ45 port supporting 10/100 Mbps data rates and two fiber optic ports using LC multimode connection standards at 100 Mbps.

What are the ambient temperature constraints for safe deployment of the module?

The module is rated for safe industrial application within a monitored ambient operating temperature range from -25 Celsius up to +60 Celsius.

What power parameters must be provided to run the network component?

The network component is engineered to operate from an input voltage rating of 24V DC, maintaining a maximum active current consumption profile of 260 mA.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...