1 จาก 3

Allen-Bradley 1794-TB3K FLEX I/O Conformal Coated Terminal Base Unit

Allen-Bradley 1794-TB3K FLEX I/O Conformal Coated Terminal Base Unit

Only 7 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-TB3K

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Conformal Coated Terminal Base Unit

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 94 mm x 94 mm x 69 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The 1794-TB3K is a specialized, ruggedized mounting and wiring component designed for the FLEX I/O distributed modular platform. This industrial hardware component forms the essential baseline configuration for remote I/O terminal assemblies, combining field-side sensor/actuator wiring points with an integrated backplane bus matrix. This specific variant features factory-applied conformal coating protection, which shields internal circuitry from corrosive atmospheric agents, humidity, and airborne contaminants often encountered in harsh operating areas.

Equipped with a three-tier terminal block configuration, the unit provides thirty-six individual termination screws to manage discrete or analog signals, power distribution paths, and common ground lines separately. The 1794-TB3K establishes backplane structural links via an integrated male/female FlexBus connector side-assembly, enabling continuous data and power transfer across the complete local modular cluster. It is standard in heavy-duty processing industries—such as wastewater treatment plants, offshore drilling platforms, pulp and paper processing plants, and chemical synthesis installations—requiring resilience against ambient environmental degradation.

Features

  • Factory conformal coating providing enhanced corrosion and moisture protection for reliability in harsh locations.
  • Three-tier termination design separating active signal lanes, power supply buses, and ground return connections.
  • Integrated slide-and-lock FlexBus connectors facilitating modular backplane scaling on a single rail.
  • Independent operational design allowing processing modules to be hot-swapped without removing field wiring.
  • Built-in mechanical alignment keys ensuring correct module matching and secure physical seating.

Applications

  • Wastewater and sewage purification processing control panels.
  • Chemical refining and corrosive chemical batching plants.
  • Marine processing platforms and coastal automation installations.
  • Pulp, paper, and heavy mineral milling processing machinery.

Technical Specifications

Parameter Specification
Manufacturer Rockwell Automation / Allen-Bradley
Brand FLEX I/O
Part Number 1794-TB3K
Component Type Conformal Coated Terminal Base Unit
Termination Type 3-Tier Screw Clamp Terminals
Number of Terminal Points 36
Wire Size Capacity 0.34 mm2 to 2.5 mm2 (22 to 12 AWG) solid or stranded copper wire
Terminal Screw Torque 0.56 to 0.79 N-m (5.0 to 7.0 lb-in)
Voltage Rating 31.2V DC / 132V AC maximum
Current Capacity 10 A maximum per power bus, 2 A maximum per signal terminal
Protection Type Conformal coated circuit board substrate
Operating Temperature 0 to 55 degC
Storage Temperature -40 to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin USA
Weight 0.14 kg
Dimensions 94 mm x 94 mm x 69 mm

Connections/Interfaces

Terminal Row Designation Function / Termination Allocation
Row A (Top Tier) Input / Output signal wire connection nodes 0 through 15
Row B (Middle Tier) Sourcing power supply voltage distribution terminals (+V)
Row C (Bottom Tier) Common signal reference return and chassis grounding links (COM/GND)

Installation Guidelines

DIN Rail Mounting

Catch the upper rear mounting claws of the assembly block onto the top edge of a standard zinc-plated 35 mm DIN rail. Press down and inward firmly on the lower edge of the enclosure until the spring-loaded metallic retaining clip snaps over the bottom track rail.

Backplane Connection

Align the side-facing male FlexBus pins of the new unit with the matching female socket of the existing module or network adapter on the rail. Slide the base laterally until the two housings mate flush and the interlocking retention clips engage.

Field Wiring Termination

Strip the insulation from the incoming field conductors to a length of approximately 7 mm. Insert the bare copper wire fully into the designated screw clamp receptacle and tighten the terminal screw to a torque rating between 0.56 and 0.79 N-m.

Corrosion Protection Preservation

Keep the protective cover plates over the FlexBus interface connections if adjacent slots on the DIN rail remain unpopulated. Avoid scratching the interior base board during cleaning or module replacement to prevent damaging the factory conformal coating film layer.

FAQ

What distinguishes this base unit from a standard 1794-TB3 model?

This unit features a factory-applied conformal coating layer on its internal circuit board components to provide extra protection against harsh environmental contaminants.

Can this unit be mixed with non-conformal coated modules on the same rail?

Yes, it is physically and electrically compatible with standard modules, though the complete system should be coated to achieve full environmental resilience.

What wire gauge range can the terminal screws safely accommodate?

The terminal blocks accept solid or stranded copper conductors ranging from 22 AWG up to 12 AWG.

Does this component support the hot-swapping of operational I/O modules?

Yes, it allows electronic application modules to be removed and inserted under power without requiring the removal of field wires or shutting down the bus adapter.

Is an external power supply run directly to this terminal block?

Yes, field-side sensor and actuator supply voltage must be wired to the Row B terminals to distribute power across the module points.

What is the maximum current limit permitted per signal terminal?

Each independent signal terminal screw is rated to handle a continuous current flow of up to 2 A.

How does the unit connect to the main system programmable logic controller?

It links back to the main controller through a communications adapter module positioned at the leftmost position of the local DIN rail track.

Can this unit handle alternating current field instrumentation loops?

Yes, the electrical insulation design allows for switching signals up to a maximum rating of 132V AC.

What tools are required to mount the base onto the DIN rail?

No tools are required for mounting, as the unit snaps directly onto the rail, but a flat-head screwdriver can be used to release the lower latch during removal.

What is the maximum torque recommendation for the terminal clamp screws?

The screws should be tightened to a value within the 0.56 to 0.79 N-m range to prevent stripping while maintaining low contact resistance.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา
Country of origin
สหรัฐอเมริกา
Power source
ใช้พลังงานไฟฟ้า ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...