1 จาก 1

Bently Nevada 190501-12-99-02 Velomitor CT Velocity Transducer

Bently Nevada 190501-12-99-02 Velomitor CT Velocity Transducer

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 190501-12-99-02

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Vibration Monitoring Sensors

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Engineered specifically for low-frequency vibration monitoring on cooling tower fans and slow-speed machinery, the Bently Nevada 190501-12-99-02 Velomitor CT utilizes an internal solid-state accelerometer and integration circuitry to provide a direct velocity output. This specialized sensor is designed to detect early-stage mechanical anomalies in harsh, high-humidity environments, facilitating proactive maintenance before operational failures occur.

By integrating the velocity transduction mechanism directly within the rugged housing, this unit eliminates the signal degradation issues commonly associated with external charge amplifiers. The configuration features a 32-foot integrated cable and a robust M8x1 plate stud mount, providing a ready-to-install solution optimized for wet, demanding industrial structures.

Features

  • Internal Integration: Combines solid-state accelerometer technology with an onboard integrator to produce a low-noise velocity output directly.
  • Extended Cabling (Option -99): Features a factory-terminated, 32-foot (approx. 9.7 meters) integrated cable to minimize field termination failure points.
  • Specialized Mounting (Option -12): Supplied with a heavy-duty Plate Stud 3/8-in 24 to M8x1 for rigid mechanical coupling to the machine casing.
  • Hazardous Area Certified (Option -02): Designed to meet multiple international explosion-proof and hazardous area standards for safe deployment in volatile zones.
  • Corrosion Resistant: Built to withstand continuous high-humidity, corrosive atmospheres typical of cooling tower wet decks.

Applications

  • Cooling tower fan gearboxes and driver shafts.
  • Induced draft and forced draft ventilation fans.
  • Low-speed industrial pumps and compressors.
  • Water and wastewater treatment rotating machinery.

Technical Specifications

Manufacturer Bently Nevada
Model Series 190501 Velomitor CT (Cooling Tower)
Full Part Number 190501-12-99-02
Mounting Option (-12) Plate Stud 3/8-in 24 to M8x1
Connection Option (-99) Integrated 32-foot (9.7m) cable
Agency Approval Option (-02) Multiple approvals (ATEX, IECEx, Division 2 / Zone 2 compliant)
Shipping Weight (Calculated) 2.0 kg (4.4 lbs)

Connections and Interfaces

Wire Color Signal Assignment Description
White SIG / PWR (+) Positive dynamic signal and loop power input
Black RET (-) Signal return / common ground reference
Shield SHIELD Drain wire connected to shield; terminate at monitor chassis ground

Empirical Engineering Insights

Alternative Models & Compatibility

The Velomitor CT (190501) features a lower frequency filter profile optimized for low-velocity cooling tower machinery compared to the standard Velomitor (330500). Do not substitute a standard 330500 sensor on a cooling tower fan unless you reconfigure the monitor's low-frequency corner limits in the 3500 rack configuration software, as doing so may cause false alarms or miss critical low-frequency blade-pass energy.

Application Pitfalls & Engineering Notes

While the integrated 32-foot cable (Option -99) provides a seamless seal against moisture ingress at the sensor head, the free end of the cable is vulnerable. Always route this cable through liquid-tight conduit up to a localized junction box. Ensure the localized junction box uses a breather drain to prevent condensation from wicking down the cable sheath and corrupting the high-impedance signal.

Commissioning & Wiring Tips

Always ensure the shield drain wire is isolated and cut back at the transducer end. Ground the shield exclusively at the monitoring system's terminal base (e.g., the 3500/42M monitor input card). Grounding the shield at both ends introduces a ground loop that will inject 50/60 Hz line noise into your dynamic vibration plot, distorting diagnostic spectrum analysis.

Installation Guidelines

CRITICAL WARNING: De-energize and lock out all power sources driving the cooling tower fan motor before entering the plenum. Confirm that the fan blade assembly has completely ceased rotation and is physically locked to prevent windmilling before attempting installation.
1
Prepare the mounting surface on the gearbox casing. It must be machined flat to a surface finish of 0.8 micrometers (32 microinches) minimum to ensure complete mechanical coupling.
2
Apply a light, uniform coating of silicone grease or acoustic coupling fluid to the mating surface of the plate stud before threading.
3
Thread the plate stud into the casing and torque the transducer body to the recommended OEM specification (typically 4.5 to 6.8 Nm) using a calibrated torque wrench. Do not use pipe wrenches or slip-joint pliers on the hex flats.
4
Secure the integrated cable using non-conductive, UV-stabilized cable ties. Ensure there is a small loop of slack near the sensor housing to decouple mechanical stress caused by structural movement.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 190501-12-99-02 Velomitor CT Velocity Transducer

What is the primary difference between the Velomitor CT (190501) and a standard Velomitor (330500)?

The Velomitor CT is specifically designed with an optimized low-frequency bandpass filter (typically starting at 1.5 Hz or 90 cpm) to detect slow-speed mechanical faults in cooling tower fans, whereas standard Velomitors are tuned for higher operational speed machinery.

Does the 190501-12-99-02 have an integral cable?

Yes, the -99 option designates that this unit includes a 32-foot (approx. 9.7 meters) integrated cable, minimizing moisture-sensitive termination junctions inside the wet deck of the cooling tower.

Where should the cable shield drain wire be grounded?

The shield drain wire must be isolated at the transducer end and terminated solely at the monitor chassis or system common ground. Grounding the shield at both ends creates ground loops that corrupt vibration signal integrity.

What mounting adapter is supplied with the -12 option?

The -12 option provides a Plate Stud adapter with a 3/8-inch 24 to M8x1 thread configuration, allowing robust connection to metric-tapped casing surfaces.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...