1 จาก 1

Bently Nevada 330854-040-25-CN 3300 XL 25 mm Extension Cable

Bently Nevada 330854-040-25-CN 3300 XL 25 mm Extension Cable

Only 8 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 330854-040-25-CN

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Proximity Probe Extension Cables

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 8.89 cm x 11.70 cm x 24.10 cm (3.50 in x 4.60 in x 9.50 in)

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Serving as a critical signal transmission link within turbine supervisory instrumentation architectures, the Bently Nevada 330854-040-25-CN bridges the gap between proximity probes and sensor housings to deliver precise displacement data. Engineered specifically for the 3300 XL 25 mm Proximity Transducer System, this cable provides impedance-matched signal paths to guarantee optimal calibration stability and prevent signal loss over distance. It features a robust Armored High Temperature FluidLoc design, preventing environmental fluids from wicking through the cable shield while ensuring maximum physical protection in severe industrial environments.

Features

  • Impedance-Matched Engineering: Constructed as a 75 ohm triaxial cable to preserve transducer calibration integrity.
  • FluidLoc Cable Technology: Prevents process fluids, moisture, and oils from migrating internally through the cable structure.
  • High-Temperature Durability: PFA-insulated core capable of withstanding extreme environmental shifts.
  • Integral Armor: Protective stainless steel armor sheath prevents mechanical pinching, abrasions, and routing damage.

Applications

  • Steam, gas, and hydro turbine shaft vibration monitoring systems.
  • Thrust and radial bearing displacement measurements in heavy industrial rotating machinery.
  • High-temperature and fluid-exposed balance-of-plant auxiliary equipment monitoring.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Bently Nevada
Model Reference 330854-040-25-CN
System Compatibility 3300 XL 25 mm Proximity Transducer System
Cable Length Option 4.0 meters (13.1 feet)
Cable Construction 75 ohm Triaxial, Perfluoroalkoxyethylene (PFA) insulated FluidLoc
Armor Option Armored High Temperature FluidLoc Cable
Capacitance 69.9 pF/m (21.3 pF/ft) typical
Operating & Storage Temp -35 degC to +200 degC (-31 degF to +392 degF)
Agency Approvals CN (Country-Specific Approvals)
Net Weight 0.140 kg (0.31 lbs)
Shipping Weight (Calculated) 1.50 kg (3.30 lbs)
Package Dimensions (Calculated) 8.89 cm x 11.70 cm x 24.10 cm (3.50 in x 4.60 in x 9.50 in)
Country of Origin United States (U.S.A.)

Empirical Engineering Insights

Alternative Models & Compatibility

This cable is highly specialized for 25 mm systems. You must avoid attempting to pair this with 5 mm, 8 mm, or 11 mm proximity systems. Subsystem component mismatches alter the overall system impedance and capacitance, which will generate major calibration errors. Ensure that the combined length of your proximity probe and this extension cable perfectly matches the targeted system length (typically 5.0 or 9.0 meters total) as designated by your Proximitor sensor calibration parameters.

Application Pitfalls & Engineering Notes

Although the FluidLoc option offers excellent resistance to process fluid wicking, care must be taken during cable routing. The minimum bend radius of the armored outer sheath must be strictly maintained (minimum of 25.4 mm or 1.0 inch) to prevent structural kinking. Mechanical stress or over-bending can lead to shielding fractures, showing up as high-frequency intermittent spikes or false vibration trips on the turbine monitoring rack.

Commissioning & Wiring Tips

Before locking the miniature coaxial connectors, thoroughly clean the connection interfaces with an approved electrical contact cleaner or isopropyl alcohol. Moisture or dirt trapped in the connector will degrade isolation resistance, leading to calibration drifts. Ensure the connectors are hand-tightened until a physical "click" is felt, then slide a protective connector boot or wrap with self-fusing silicone tape to prevent ground loops and ambient contaminant ingress.

Installation Guidelines

CRITICAL WARNING

Isolate and de-energize the machine and monitoring rack before starting extension cable replacement or installation. Failure to disconnect active proximity circuits can result in unexpected monitoring system trips or electrostatic damage to sensitive internal transducer components.

1 Route the armored cable through dedicated protective conduit paths away from high-power alternating current (AC) cables to eliminate electromagnetic interference.
2 Connect the extension cable to the proximity probe's integral lead cable. Tighten until the positive locking mechanism engages fully.
3 Insulate the coaxial connector junction from the surrounding machine metal or conduit structure using a connector protective boot or self-fusing tape to prevent unwanted ground loop interference.
4 Verify total loop capacitance using a calibrated multimeter before re-energizing the Proximitor sensor for operation.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330854-040-25-CN 3300 XL 25 mm Extension Cable

Can this extension cable be used with standard 8 mm proximity systems?

No, this cable is specifically matched to the impedance and electrical characteristics of the 3300 XL 25 mm proximity transducer series. Intermixing components with other probe diameters will cause severe calibration shift.

What protection does the FluidLoc option provide?

The FluidLoc cable construction prevents moisture, oil, and other industrial process fluids from migrating through the internal spaces of the triaxial cable shield, protecting both the connection points and the transducer electronics.

How should the coaxial connections be secured during commissioning?

Connections should be hand-tightened until a distinct mechanical click is felt. To prevent ground loops and environmental ingress, apply self-fusing silicone tape over the mated connector junction.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...