1 จาก 3

Bently Nevada 3500/20 125744-02 Rack Interface Module

Bently Nevada 3500/20 125744-02 Rack Interface Module

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/20 125744-02

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Rack Interface Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 910g

  • Dimensions: 241.3 mm x 24.4 mm x 241.8 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The Bently Nevada 125744-02 is a full-height Standard Rack Interface Module (RIM) that serves as the primary data and configuration link to the 3500 Series Machinery Protection System. This module supports a specialized proprietary communication protocol designed to safely configure monitoring chassis hardware and retrieve non-critical diagnostic machinery information for host software packages. It must be placed in slot 1 of the chassis rack structure directly next to the system power supply modules. While the 125744-02 executes vital baseline management roles including processing global system contact inputs, handling trip multiply controls, and running the internal OK relay, it functions independently of the critical machinery safety trip path, ensuring that any module-level service action has zero effect on the continuous, normal protective operations of the monitoring system.

Features

  • Standard full-height front rack architecture optimized for slot 1 integration 
  • Direct physical interface for proprietary system programming and diagnostics data collection 
  • Front-panel keylock module allowing explicit hardware switching between RUN and PROGRAM modes 
  • Dedicated "OK" relay output indicating overall 3500 protection rack health and internal diagnostics status 
  • Front-panel status LEDs providing physical validation for system communications, errors, and trip conditions 
  • Integrated front-panel rack reset pushbutton to clear active latched machinery alarms 

Applications

  • Main hardware integration point for standard configuration on 3500 machinery protection loops 
  • Condition monitoring data collection interfaces for industrial power turbines and compression lines 
  • Central localized control platform for large multi-slot machine casing and rotation protection frameworks 

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada (A Baker Hughes Company)
Model 125744-02
Module Type Standard Rack Interface Module
Power Consumption 4.75 watts, typical 
Front Panel Interface RS232 serial communications at 38.4 k baud 
OK Relay Output Rating 5A @ 24 Vdc / 120 Vac (120 Watts / 600 VA Switched Power max) 
Operating Temperature -30 degC to +65 degC (-22 Fahrenheit to +150 Fahrenheit) 
Storage Temperature -40 degC to +85 degC (-40 Fahrenheit to +185 Fahrenheit) 
Relative Humidity 95%, non-condensing 
Rack Space Requirement (Main Board) 1 full-height front slot (Slot 1) 
Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 241.8 mm (9.5 in x 0.96 in x 9.52 in) 
Module Weight 0.91 kg (2.0 lb) 
Country of Origin United States

Connections/Interfaces

Interface Component Function
Front Panel Configuration Port Dedicated RS232 serial interface utilizing proprietary protocol for localized data collection and laptop rack setup 
Configuration Keylock Switch Rotational physical safety lock to switch between RUN mode (locks out changes) and PROGRAM mode (permits rack configuration) 
Chassis Status LEDs OK, TX/RX, TM (Trip Multiply), and CONFIG OK panel lamps indicating module operation and multi-card communication status 

Installation Guidelines

  • Slot Restrictions: Slide the interface card explicitly into the full-height Slot 1 location on the far left side of the machine protection rack.
  • Electrostatic Discharge Precautions: Utilize a proper grounding wrist strap connected to a solid electrical earth before inserting or setting up the circuit cards.
  • Keylock Integrity: Turn the front key switch to RUN position and extract the physical key to securely block unauthorized remote or local modification attempts.
  • Thermal Management: Ensure that cooling pathways are completely clear, maintaining the ambient temperature immediately surrounding the module chassis below 65 degC.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/20 125744-02 Rack Interface Module

What is the functional difference between RUN mode and PROGRAM mode on this module?

RUN mode permits typical system protective operation while completely locking out configuration changes. PROGRAM mode keeps the rack protective pathways running normally while opening the localized ports to allow engineers to change settings or updates.

Does a firmware update or a technical problem with this interface drop the machine trip loop?

No, the module performs configuration, diagnostic collection, and status tasks. It is placed outside the critical emergency protective monitoring loop and has no effect on individual monitor card shutdown capabilities.

How do you change or clear latched warning signs on the rack using this module faceplate?

Press the physical Rack Reset switch located on the front panel face to clear active latched machinery alerts or reset Timed OK Channel Defeat states.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
เงิน
Country of origin
สหรัฐอเมริกา
Power source
ใช้พลังงานไฟฟ้า ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...