1 จาก 3

Bently Nevada 3500/77M-03-00 143729-01 Recip Cylinder Pressure Monitor

Bently Nevada 3500/77M-03-00 143729-01 Recip Cylinder Pressure Monitor

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/77M-03-00 143729-01

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Reciprocating Compressor Monitor Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1110g

  • Dimensions: 241.3 mm x 24.4 mm x 241.8 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

The Bently Nevada 3500/77M-03-00 is a high-performance, 4-channel Recip Cylinder Pressure Monitor programmed via the 3500 Rack Configuration Software to deliver continuous machinery protection and critical diagnostics for reciprocating compressors. This monitoring assembly operates as a unified dual-module system, combining the main front-slot processor with the essential 143729-01 Cylinder Pressure I/O Module with Internal Terminations. The system accepts positive voltage, third-party absolute pressure transducer signals (psia) approved by the manufacturer, providing both localized machine protection and high-fidelity transient data for plant operations and maintenance engineering crews.

The module conditions dynamic pressure waveforms to extract eight distinct measured variables per active channel. Five parameters map specifically to a single compression chamber: Discharge Pressure, Suction Pressure, Maximum Pressure, Minimum Pressure, and Compression Ratio. An additional three variables integrate multiple channel values alongside geometric compressor parameters to compute advanced thermodynamic and mechanical states: Peak Rod Compression, Peak Rod Tension, and the Degree of Rod Reversal. The rear-mounted 143729-01 I/O module provides the indispensable physical termination blocks and transducer excitation, making it a critical component of the overall 3500 Series Machinery Protection System deployment.

Features

  • Continuous 4-channel real-time conditioning and dynamic processing of approved positive-voltage pressure inputs.
  • Requires the 143729-01 rear card to facilitate secure field sensor wiring via internal termination points.
  • Computes specialized reciprocating variables including rod reversal angles and rod tension/compression limits.
  • Configurable alert setpoints across all measured variables and danger setpoints for any two combined variables per channel.
  • Integrated front-panel buffered coaxial connections for unconditioned pressure waveform diagnostics.
  • Front panel status LEDs provide instantaneous verification of monitor verification states (OK), bus communication activity (TX/RX), and bypass status.

Applications

  • Multi-chamber dynamic cylinder pressure diagnostics on double-acting reciprocating compressors.
  • Crosshead pin mechanical stress assessment and rod load calculation in petrochemical processing.
  • Continuous discharge, suction, and peak pressure tracking on high-pressure refinery gas skids.
  • Real-time rod reversal confirmation for heavy-duty gas transmission and reinjection machinery.

Ordering Information

  • 3500/77M: Recip Cylinder Pressure Monitor
  • 03: Cylinder Pressure I/O Module with Internal Terminations
  • 00: None Agency Approval Option
  • 143729-01: Cylinder Pressure I/O Module Spare (Internal Terminations for Bently Approved Third-Party Pressure Transducers)

Technical Specifications

Parameter / Category Specification Details
Electrical & Power
Manufacturer Bently Nevada
Country of Origin USA
Power Consumption 7.8 Watts maximum (with transducer supplies at full load)
Transducer Power Supply +23.0 +/- 0.8 Vdc with 24.5 mA current limiting per channel
Input Impedance 50 kOhm (Cylinder Pressure I/O)
Signal Input & Ranges
Channel Capacity 1 to 4 channels of approved 3rd-party psia transducers
Transducer Scale Factors

95,000 mV/psi for 100 psia range


38,000 mV/psi for 250 psia range


19,000 mV/psi for 500 psia range


9,500 mV/psi for 1000 psia range


3,800 mV/psi for 2500 psia range


1,900 mV/psi for 5000 psia range


950 mV/psi for 10,000 psia range

Scale Reference Assumes +0.5 Vdc at 0 psia and +10.0 Vdc at full-range value
Performance & Accuracy
Frequency Response 0 to 5.5 kHz on all configured pressure channels
Accuracy at +25 degC Within +/- 0.5% of full-range (9.5 Volts: From +0.5 to +10.0 Volts)
Accuracy over Temperature Within +/- 1.0% of full-range over -30 degC to +65 degC range
Measured Variables Discharge Pressure, Suction Pressure, Maximum Pressure, Minimum Pressure, Compression Ratio, Peak Rod Compression, Peak Rod Tension, Degree of Rod Reversal
Signal Outputs
Buffered Output Connections 1 short-circuit protected coaxial connector per channel (Front panel)
Buffered Output Impedance 550 Ohm
Buffered Signal Offset Electronically inverted and offset by -2.265 Vdc
Environmental Limits
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Ambient Humidity 95% non-condensing
Mechanical Dimensions & Weight
Main Monitor Dimensions 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
Main Monitor Weight 0.91 kg (2.0 lb.)
Rear I/O Module Dimensions 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Rear I/O Module Weight 0.20 kg (0.44 lb.)
Total Assembly Weight 1.11 kg (2.44 lb.) combined system weight
Rack Space Requirements 1 full-height front slot (Monitor) and 1 full-height rear slot (I/O)

Connections/Interfaces

Connector Type / Location Function Assignment
Front Panel Coaxial Jacks (1-4) Dynamic buffered transducer output points for oscilloscope verification
Rear 143729-01 Screw Terminals Field transducer signal inputs and +23.0 Vdc excitation distribution

Installation Guidelines

  • Dual-Module Pairing: Complete physical installation requires inserting the main processor board into a front chassis slot, and mounting the 143729-01 I/O module into the rear chassis slot directly behind it.
  • Chassis Slot Selection: The front slot must be a full-height monitoring position (slots 2 through 15). Slots 0 and 1 are strictly reserved for power and rack interface modules.
  • Transducer Shielding: Wire all third-party pressure sensors using high-quality twisted-pair shielded cable. Connect the shielding braid exclusively to the dedicated chassis ground terminals on the 143729-01 card.
  • Excitation Load Verification: Ensure the combined power draw of the external sensors does not trigger the 24.5 mA current limiting safety threshold on any individual channel.
  • Signal Offset Awareness: Note that dynamic waveform diagnostic data collected from the front panel coaxial connectors is electronically inverted and offset by -2.265 Vdc due to the internal routing architecture of the rear I/O module.

FAQ

What is the function of the 3500/77M-03-00 module system?

It monitors dynamic cylinder pressure profiles and rod loads to protect and diagnose industrial reciprocating compressors.

Why is the 143729-01 rear card necessary for this system?

The 143729-01 is the mandatory Cylinder Pressure I/O module that houses the physical field wiring terminals and sensor power circuits.

How many sensor input channels does this combined module assembly support?

The monitor system provides processing infrastructure and termination blocks to handle 1 to 4 independent transducer lines.

What types of pressure sensors can be wired to the 143729-01 card?

It is built specifically to accept approved positive-voltage third-party transducers calibrated in absolute pressure metrics (psia).

Which parameter calculations require the input of physical machine dimensions?

Calculations for Peak Rod Compression, Peak Rod Tension, and the Degree of Rod Reversal integrate real-time waveforms with stored mechanical geometry data.

What is the power specification for sensor excitation on the rear card?

The rear module delivers +23.0 +/- 0.8 Vdc on each channel, protected by a 24.5 mA current limiting circuit.

What standard input electrical impedance value is present on the I/O channels?

The hardware channels feature a nominal internal electrical input impedance rating of 50 kOhm.

Are the front panel buffered coaxial outputs identical to the raw sensor input wave?

No, the front buffered outputs are electronically inverted and offset by -2.265 Vdc by the cylinder pressure I/O module routing.

What is the maximum signal frequency response of the pressure tracking channels?

The continuous frequency response range extends from 0 to 5.5 kHz across all active channels.

Can the complete monitor assembly operate in sub-zero environments?

Yes, the front module and the rear I/O card are fully specified to operate in ambient industrial environments down to -30 degC.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/77M-03-00 143729-01 Recip Cylinder Pressure Monitor

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีขาวอมเทา เงิน
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...