Honeywell 10310/2/1 Fail Safe Control Earth Leakage Detector

Honeywell 10310/2/1 Fail Safe Control Earth Leakage Detector

Only 4 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 10310/2/1

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Earth Leakage Detectors

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 180 mm x 120 mm x 60 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Integrating directly into Honeywell Fail Safe Control (FSC) and Safety Manager architectures, the Honeywell 10310/2/1 functions as a specialized DC earth leakage detector to monitor insulation degradation and ground faults. This module continuously evaluates DC distribution systems to detect active ground faults before they escalate into systemic failures or hazardous plant shutdowns. Operating on a nominal 24 VDC power supply, the unit maintains a balanced earth reference of -12 VDC under normal, non-fault operating conditions. Any electrical current imbalance on the DC loop is registered by the internal monitoring circuitry, triggering an output relay once the current leakage exceeds a predefined threshold limit.

Key Features

  • Continuous DC Supervision: Real-time insulation integrity monitoring of balanced 24 VDC power networks.
  • Multi-Mode Frequency Switching: Selectable DC mode for operational monitoring alongside 1 Hz and 0.25 Hz pulsed modes for pinpointing localized earth faults.
  • Integrated Self-Test Capability: Front-accessible manual test function allows validation of physical loop integrity and output relays.
  • Dual Reset Controls: Supports both local manual reset and remote reset integration via designated 24 VDC or 110 VAC inputs.
  • Front-Panel Diagnostics: High-visibility LED indicator displays live status variations and selected test pulse frequencies.

Applications

  • Emergency Shutdown Systems (ESD) and safety-critical process networks.
  • Petrochemical, oil and gas, and refining safety management platforms.
  • High-availability DC auxiliary power panels in heavy utility generation plants.

Technical Specifications

Parameter Value / Specification
Manufacturer Honeywell
Model Number 10310/2/1
System Compatibility Fail Safe Control (FSC) / Safety Manager
Nominal Supply Voltage 24 VDC
Operating Voltage Range 18 VDC to 30 VDC
Normal Earth Reference -12 VDC
Leakage Trip Threshold 5.5 mA +/- 1 mA
Signal Outputs Dry contact relay output
Contact Power Rating 1 A at 115 VAC or 100 W at 24 VDC
Operating Pulse Frequencies DC (Normal), 1.0 Hz (Fast), 0.25 Hz (Slow tracing)
Mounting Configuration DIN rail or FSC Rack Interface (Slot positions A5, A11)
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 180 mm x 120 mm x 60 mm

Connections and Interfaces

Interface Type Electrical Assignment
Rst24 Terminal Remote manual reset input via standard 24 VDC signal pulse
Rst110 Terminal Remote manual reset input via high-voltage 110 VAC signal pulse
Relay Contact Blocks Potential-free changeover contact for remote DCS or Safety Manager fault registration

Empirical Engineering Insights

Alternative Models & Compatibility

The 10310/2/1 is engineered specifically for Safety Manager and Fail Safe Control (FSC) hardware revisions. While physical slide-in mounting fits standard A5 and A11 slot matrices, verify existing system bus revisions to ensure backplane compatibility with remote software reset calls.

Application Pitfalls & Engineering Notes

During heavy inductive switching or when system lines feature highly distributed cable lengths, parasitic capacitance can induce transient currents. This dynamic capacitive charging can cause nuisance tripping near the 5.5 mA leakage threshold. Segment the DC distribution if line capacitance consistently breaches typical operational limits.

Commissioning & Wiring Tips

When utilizing the low-frequency 0.25 Hz pulsed mode to locate localized earth faults in the field, use a low-frequency current clamp paired with a high-impedance digital multimeter. Standard clamp-on sensors often register 0.25 Hz pulses as thermal drift, yielding incorrect readings.

Installation Guidelines

CRITICAL WARNING: De-energize and lock out all upstream DC power distribution systems before executing physical installation. Do not ground or jumper the reference earth terminal during operations, as accidental reference shorts can damage the internal sensing circuits of adjacent control modules in the FSC rack.
1
Install the module into the designated DIN rail mounting space or securely slide it into position within designated FSC rack slots (A5 or A11).
2
Connect the 24 VDC primary power supply lines and secure the dedicated earth ground reference wiring to the local terminal strip.
3
Integrate the relay contact monitoring connections directly into the safety system's functional alarm logic inputs.
4
Activate control system power and press the front manual test button to confirm real-time system alarm actuation and relay health.

What is the primary function of the Honeywell 10310/2/1 module?

It serves as an Earth Leakage Detector (ELD) that continuously monitors 24 VDC distribution networks inside Fail Safe Control (FSC) and Safety Manager panels for ground path insulation breakdown.

How do the 1 Hz and 0.25 Hz pulse modes assist field technicians?

These modes pulse the earth reference path at low frequencies to allow technicians to trace the physical path of a ground fault using a specialized DC current clamp and voltmeter without taking the system offline.

What are the remote reset electrical ratings for the 10310/2/1?

The module features distinct remote reset inputs: Rst24 for standard 24 VDC safety logic loops and Rst110 for high-voltage 110 VAC signal loops.

How does the module respond to a ground leakage event?

Once earth leakage current exceeds the calibrated 5.5 mA threshold, the dry relay contacts change state, initiating alarm logic in the Safety Manager.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...