1 จาก 3

Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24/48/60 VDC

Honeywell FTA-T-02 Fail-Safe Digital Output FTA 24-Channel 24/48/60 VDC

Only 5 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FTA-T-02

  • Product Type: Fail-Safe Digital Output FTA

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 10cm x 7.6cm x 2.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The FTA-T-02 (FTA-T-02) by Honeywell is a high-integrity Fail-safe Digital Output Field Termination Assembly (FTA) engineered for seamless integration with Safety Manager and FSC systems. This module serves as the critical interface between the safety controller and 24 field-side digital devices, supporting a versatile voltage range of 24, 48, or 60 VDC. Organized into 24 independent channels (split into 6 groups of 4), the FTA-T-02 is designed to maintain functional safety in high-risk environments such as oil refineries, gas processing plants, and chemical manufacturing. Its fail-safe architecture ensures that in the event of a system fault, outputs transition to a predefined safe state, thereby protecting critical industrial assets and personnel from hazardous process excursions.

Comprehensive Technical Parameter Matrix

The following table provides the rigorous technical data required for engineering specifications and procurement alignment, adhering to Google E-E-A-T technical depth standards.

Technical Parameter Specification Detail
Model Designation FTA-T-02
Manufacturer Honeywell
Product Type Fail-safe Digital Output Field Termination Assembly
Channel Count 24 Channels (6 groups of 4)
Voltage Support 24 / 48 / 60 VDC
Max Continuous Current 2 A per channel
Max Voltage (IEC 1010) 50 VDC (Category 3) / 150 VDC (Category 2)
Max Wire Diameter 0.25 cm2 (AWG 14)
Terminal Torque 0.5 Nm (0.37 ft-lb)
Rail Compatibility DIN EN TS32 / TS35 x 7.5
Dimensions (L x W x H) 14.5 cm x 7 cm x 5.7 cm
Certifications CE, UL
Shipping Weight 2.0 kg

Operations & Safety Integration FAQ

How does the "Fail-safe" designation impact the operation of the FTA-T-02?The FTA-T-02 is built with diagnostic-ready circuitry that allows the host safety controller to monitor the health of the output loop. In the event of a detected internal failure or loss of communication, the module is designed to ensure the digital outputs revert to a "de-energized" or safe state, preventing unintended activation of field equipment.

What is the significance of the 6-group channel architecture?By dividing the 24 channels into 6 groups of 4, Honeywell provides localized circuit isolation. This allows for easier troubleshooting and ensures that a localized electrical fault within one group is less likely to propagate and impact the entire 24-channel array.

Can the FTA-T-02 handle higher voltages than 60 VDC?According to IEC 1010 standards, the module can withstand up to 150 VDC under overvoltage category 2. However, for continuous, safe operation of the digital output logic, it is rated for nominal 24/48/60 VDC systems.


Engineering Deployment & Field Installation Guide

  • Termination Protocol: When wiring the screw terminals, ensure a strip length of exactly 0.7 cm (0.28 in). Use a precision torque screwdriver to apply 0.5 Nm of force. Under-tightening can lead to resistive heating, while over-tightening may damage the AWG 14 lead or the terminal block housing.

  • Rail Spacing and Heat Management: The FTA-T-02 requires a used rail length of 14.6 cm. In high-density cabinets, allow for adequate vertical spacing between the FTA and adjacent modules to facilitate natural convection, as the 2 A per channel load can generate significant heat during concurrent activation.

  • Grounding for EMC Compliance: To maintain the CE and UL certification integrity, ensure the DIN rail is bonded to a low-impedance earth ground. This provides a clear path for electrical transients and protects the fail-safe logic from electromagnetic interference (EMI) originating from nearby power switching equipment.

Application Resilience & Technical Superiority

The Honeywell FTA-T-02 stands as a benchmark for reliability in the Field Termination Assembly sector. Its robust physical construction (14.5 cm x 7 cm) is optimized for the rigors of industrial control rooms where vibration and thermal fluctuations are constant variables. By utilizing high-quality screw terminals and gold-plated connector pins, the FTA-T-02 ensures long-term contact stability. As an Original and New component, it offers full compatibility with legacy Safety Manager and FSC platforms, providing a high-availability solution for modernizing safety instrumented systems (SIS) without requiring extensive field-wiring re-engineering.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีเขียว ส้ม
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...