1 จาก 1

Notifier by Honeywell 30-3013 Explosion-Proof Smoke Detector

Notifier by Honeywell 30-3013 Explosion-Proof Smoke Detector

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 30-3013

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Explosion-Proof Smoke Detector

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The Notifier 30-3013 is a high-performance explosion-proof smoke detector engineered for hazardous industrial locations. This unit utilizes a light-scattering infrared photodiode sensor for reliable detection of both smoldering and flaming fires. Designed for integration into fire alarm control panels (FACP) via 2-wire or 4-wire configurations, it is primarily deployed in oil and gas refineries, chemical processing plants, offshore platforms, and volatile storage facilities. The assembly consists of a precision-engineered smoke sensor head and a heavy-duty, copper-free aluminum junction box designed to contain internal explosions and prevent the ignition of external flammable atmospheres. It maintains stable operation across a wide temperature range and is compatible with various industrial fire suppression systems.

Technical Specifications

Attribute Details
Model 30-3013
Brand Notifier by Honeywell
Product Type Explosion-Proof Smoke Detector
Detection Method Photoelectric (Light-scattering)
Operating Voltage 12 - 32 VDC
Current Consumption 10 mA (Alarm), 100 µA (Standby)
Enclosure Material (Sensor) Polycarbonate / ABS
Enclosure Material (J-Box) Copper-free aluminum (painted)
Operating Temperature –20°C to 65°C (–4°F to 149°F)
Storage Temperature –55°C to 70°C (–67°F to 158°F)
Humidity Range 5% to 95% RH (Non-condensing)
Shipping Weight 5.0 Kg (approx. 11 lbs)
Area Classification Class I, Div 1 & 2, Groups B, C, D; Class II, Div 1 & 2
Protection Rating NEMA 4X / IP66 (Junction Box)

Engineering & Installation Guide

Field Wiring and Grounding

When installing the 30-3013 in hazardous areas, all field wiring must comply with the National Electrical Code (NEC) or local equivalent standards for Class I/II locations. Use shielded twisted pair cable for 2-wire loops to minimize electromagnetic interference (EMI). Ensure the junction box is properly grounded via the internal grounding screw to prevent static buildup and ensure the integrity of the flamepath.

Replacement and Maintenance

The smoke detector head is calibrated to specific sensitivity levels at the factory. During routine maintenance, do not attempt to disassemble the sensor head. If the unit fails self-diagnostics or enters a fault state during testing, the sensor assembly must be replaced as a single unit. Always verify that power is disconnected before opening the explosion-proof junction box to prevent ignition risks.

Environmental Considerations

While the junction box is rated for industrial use, the smoke entry ports must be kept clear of heavy dust accumulation or paint overspray. In high-vibration environments, ensure all conduit entries are secured with approved explosion-proof seals (EYS) to prevent moisture ingress and flame propagation through the conduit system.

FAQ

Is the 30-3013 compatible with third-party Fire Alarm Control Panels?

Yes, the 30-3013 is designed to operate on standard 2-wire or 4-wire 24VDC loops, making it compatible with most industrial FACPs that support conventional smoke detectors.

How is the sensitivity of the detector verified in the field?

Sensitivity testing should be performed using calibrated aerosol smoke or specialized testing equipment designed for explosion-proof housings. There is no manual sensitivity adjustment on the unit to ensure factory-set safety thresholds are maintained.

What is the recommended replacement cycle for the sensor head?

In accordance with NFPA 72 guidelines and typical industrial lifecycle management, it is recommended to inspect the unit annually and consider replacement every 10 years, or sooner if deployed in highly corrosive or oil-mist heavy environments.

 

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
แดง
Country of origin
สหรัฐอเมริกา
Power source
ไฟฟ้ากระแสตรง

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...