1 จาก 1

Omron E5CZ-Q2MT AC100-240 E5CZ Series Digital Temperature Controller

Omron E5CZ-Q2MT AC100-240 E5CZ Series Digital Temperature Controller

Only 3 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: E5CZ-Q2MT AC100-240

  • Country of origin:ญี่ปุ่น

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 48 x 48 x 85 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

For critical thermal regulation loops, the Omron E5CZ-Q2MT AC100-240 process controller provides high-accuracy PID control within a standard 1/16 DIN footprint. Built with a highly responsive 150 ms sampling period, this multi-input unit supports a wide array of temperature sensors and analog inputs, delivering stable control outputs for demanding industrial thermal processes. Equipped with a 12 VDC voltage output, it is engineered specifically to cycle external solid-state relays (SSRs) with minimal switching latency, while its dual auxiliary outputs allow for independent alarm configuration and system protection loops.

Features

  • Universal Input Flexibility: Supports diverse inputs including Thermocouples, Platinum Resistance Thermometers (Pt100/JPt100), and analog voltage/current signals.
  • High-Speed Processing: 150 ms sampling loop updates control calculations continuously to handle fast thermal response systems.
  • SSR Control Output: Generates a robust 12 VDC voltage output to drive high-performance solid-state relays.
  • Dual Alarm Relays: Two independent auxiliary SPST-NO relay outputs for comprehensive high/low limit and deviation monitoring.
  • Clear Dual Display: 11-segment PV/SV characters provide high-contrast visualization of active process states and target setpoints.

Applications

  • Industrial packaging machinery sealing bars and hot-melt adhesive units
  • Plastic extrusion lines and injection molding machine barrel zones
  • Food processing ovens, sterilizers, and pasteurization systems
  • Environmental simulation chambers and laboratory incubation systems

Technical Specifications

Specification Parameter Technical Value
Power Supply Voltage 100 to 240 VAC, 50/60 Hz
Operating Voltage Range 85% to 110% of rated voltage
Power Consumption 6.0 VA maximum
Sensor Inputs (Multi-Input) Thermocouple (K, J, T, E, L, U, N, R, S, B, W, PL II), Platinum RTD (Pt100, JPt100), Analog Current/Voltage
Control Output (Voltage) 12 VDC, 21 mA (with short-circuit protection)
Auxiliary Outputs 2 SPST-NO relay outputs (250 VAC, 1 A resistive load)
Control Method 2-PID control (with auto-tuning) or ON/OFF control
Sampling Period 150 ms
Enclosure Rating Front Panel: IP66, Rear Case: IP20, Terminals: IP00
Ambient Operating Temperature -10 to 55 degC (no condensation or icing)
Manufacturer Omron Corporation
Country of Origin Japan
Shipping Weight (Calculated) 0.15 kg
Package Dimensions (Calculated) 48 x 48 x 85 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CZ series represents a critical historical bridge in Omron's temperature controller catalog. While physical dimensions match the older E5CN generation, verify terminal numbers prior to swap-outs because terminal configurations vary between generations. For modern deployments requiring even faster loop responses (50 ms) and larger display configurations, consider upgrading to the E5CC-QX2DSM-800 series.

Application Pitfalls & Engineering Notes

When utilizing the 12 VDC voltage output to drive multiple external solid-state relays in parallel, verify that the total switching current does not exceed the internal 21 mA current limit. Exceeding this rating will cause the voltage output to drop below the minimum SSR trigger threshold, resulting in unstable heating loops and potential controller damage. Always maintain a separate physical run for high-voltage element power lines and low-voltage controller input cables to avoid EMI-induced measurement drift.

Commissioning & Wiring Tips

When running auto-tuning routines for the first time, allow the thermal system to reach standard ambient conditions first. Initiating auto-tuning on an already hot system will calculate incorrect derivative and integral constants, resulting in excessive process value overshoot during normal operation. If using thermocouple sensors, only use correct compensation cables directly to the terminal block to prevent cold junction compensation reference errors.

Installation Guidelines

CRITICAL WARNING

Isolate and verify the de-energization of all power supply and auxiliary circuit loops prior to terminal installation or module extraction. Failure to de-energize primary AC lines can result in severe electrical shock, system circuit damage, or hazardous false triggers on connected heating elements.

1
Prepare a precise 45 x 45 mm square panel cutout. Ensure panel thickness is between 1 and 5 mm.
2
Insert the controller housing through the front of the panel cutout and slide the securing adapter from the rear until it latches tightly against the panel.
3
Wire terminals using crimped spade or ring terminals, adhering to the wiring diagram shown on the side of the controller case. Torque screw terminals to 0.74 N-m.
4
Apply power, enter the advanced setup menu, and match the input type parameter to the physical temperature sensor connected to the device.

What is the control output rating of the E5CZ-Q2MT controller?

This model features a 12 VDC voltage output rated for 21 mA, designed specifically to drive external solid-state relays (SSRs) directly without an auxiliary power supply.

Does this temperature controller support both thermocouples and RTDs?

Yes. It is a multi-input controller that supports standard thermocouples (such as K, J, and T) and platinum resistance thermometers (Pt100 and JPt100), selectable via the internal parameter menu.

How do I clear or reset an alarm on the E5CZ-Q2MT?

Alarms can be configured as latching or non-latching. Latching alarms can be reset by cycling the power supply or configuring an event input to trigger an alarm reset command.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...