1 จาก 1

Omron S8VK-T96024 S8VK-T 3-Phase Switch Mode Power Supply

Omron S8VK-T96024 S8VK-T 3-Phase Switch Mode Power Supply

Only 4 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: S8VK-T96024

  • Country of origin:ญี่ปุ่น

  • Product Type: Switch Mode Power Supplies

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Delivering robust high-capacity DC power to complex industrial networks, the Omron S8VK-T96024 is a professional-grade, three-phase switch mode power supply built for space efficiency and reliable DIN-rail mounting. This 960W power module is designed to withstand harsh operating environments, offering high vibration resistance and wide temperature tolerance. Optimized for heavy-duty automation systems, the unit easily handles high startup currents with its built-in power boost functionality, ensuring stable 24 VDC delivery even under fluctuating load conditions.

Key Features

  • Three-Phase Input: Direct compatibility with standard industrial three-phase power lines simplifies installation and balances phase loading.
  • High Power Density: Compact footprint maximizes limited enclosure backplate space without sacrificing output capacity.
  • Advanced Power Boost: Sustains up to 120% of rated current dynamically to clear capacitive and inductive start-up loads.
  • Marine and Heavy Industry Approvals: Designed to meet rigorous vibration, shock, and electrical safety standards required for heavy machinery.

Applications

  • Automotive assembly plant control panels and robotic work cells.
  • Water and wastewater municipal pump station control cabinets.
  • Packaging, material handling, and high-speed sorting conveyor architectures.
  • Marine engine room monitoring panels and offshore platform auxiliary power.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Reference S8VK-T96024
Power Rating 960 W
Input Voltage (Nominal) 3-Phase 380 to 480 VAC
Input Voltage Range 320 to 576 VAC (3-phase) or 450 to 810 VDC
Output Voltage 24 VDC
Output Current 40 A
Voltage Adjustment Range 22.5 to 29.5 VDC (via front-panel potentiometer)
Efficiency (Typical) 91% at 400 VAC input
Mounting Method 35mm DIN Rail
Operating Temperature Range -40 to 70 degC (Refer to derating curve above 55 degC)
Shipping Weight (Calculated) 3.8 kg
Dimensions (Calculated) 150 mm (H) x 110 mm (W) x 121.9 mm (D)

Connections and Interfaces

Terminal Designation Function / Assignment
L1, L2, L3 Three-phase AC power input lines
PE (Protective Earth) Safety ground connection
+V (3 terminals) Positive 24 VDC output lines
-V (3 terminals) Negative 24 VDC output (return) lines
DC OK Relay (2 terminals) Dry contact status output (closed when DC output voltage is normal)

Empirical Engineering Insights

Alternative Models & Compatibility

The S8VK-T96024 serves as a highly robust replacement for legacy Omron three-phase modules (such as the older S8VS or S8VM ranges). Because of its significantly reduced physical width, it easily retrofits into crowded electrical cabinets without requiring terminal layout modifications. Ensure that any system integration utilizes three-phase AC input to achieve full efficiency, though emergency degraded operation on two-phase input is supported at reduced output capacities.

Application Pitfalls & Engineering Notes

To guarantee optimal performance, thermal dissipation must be accounted for in sealed control panels. Avoid mounting heat-generating devices directly below this power supply. A minimum clearance of 15mm is recommended on both sides when deployed in high-temperature environments (above 55 degC) to prevent triggering internal overtemperature protection protocols.

Commissioning & Wiring Tips

The output voltage must be verified at the furthest load point under full-load conditions. Use the front-panel potentiometer (V.ADJ) to compensate for any voltage drop over long DC cable runs. High-quality copper conductors rated for at least 75 degC must be utilized to handle the continuous 40A secondary current safely.

Installation Guidelines

CRITICAL WARNING:

Risk of severe electrical shock. Ensure all primary AC feed breakers are fully de-energized, locked out, and tagged out prior to making or modifying any electrical connections. Wait at least 5 minutes post-power-off to allow internal high-voltage capacitors to fully discharge before handling terminals.

1

Mount the power supply horizontally onto a clean, undamaged 35mm DIN rail, ensuring the unit clicks securely into place.

2

Connect the PE (Protective Earth) line first to establish a reliable chassis ground connection before wiring active phases.

3

Terminate the input power lines to L1, L2, and L3 terminals using ferruled, multi-strand copper cables to prevent hot spots.

4

Connect the load-side cabling to the +V and -V terminal pairs, ensuring clean, balanced parallel conductor routing if distributing full 40A currents.

Can the S8VK-T96024 operate continuously under a two-phase input fault condition?

Yes, this model supports two-phase operation under emergency circumstances, but output load current must be derated according to OEM specifications to prevent thermal overload.

What is the function of the DC OK relay output?

It is a dry contact output that remains closed during normal 24VDC operation. It opens if the output voltage drops below approximately 90% of the set value, allowing quick system diagnostics.

Does this power supply require external ventilation fans?

No, it is convection-cooled. However, keeping recommended side clearances of at least 15mm and top/bottom clearances of 50mm ensures stable operation up to high ambient limits.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
ญี่ปุ่น

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...