ProSoft PLX31-MBTCP-MBS4 Modbus TCP/IP to Modbus Serial 4 Port Gateway

ProSoft PLX31-MBTCP-MBS4 Modbus TCP/IP to Modbus Serial 4 Port Gateway

Only 10 item(s) left in stock
  • Manufacturer: ProSoft

  • Product No.: PLX31-MBTCP-MBS4

  • Country of origin:สหรัฐอเมริกา

  • Product Type: Protocol Gateways

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Dimensions: 13.67 x 5.05 x 11.13 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

Facilitating seamless bidirectional communication between Ethernet and serial-based field networks, the ProSoft PLX31-MBTCP-MBS4 acts as a robust protocol converter for industrial automation systems. This module enables a Modbus TCP/IP client or server to interface directly with up to four independent Modbus Serial networks, bridging the gap between legacy serial instruments and modern Ethernet control architectures. Engineered for high-reliability environments, it provides galvanic isolation on all communication paths and features a rugged, compact enclosure designed for DIN-rail mounting. With integrated diagnostics, a flexible power supply input, and individual port configuration, this gateway ensures low-latency data transmission across diverse factory automation, water treatment, and power distribution infrastructures.

Features

  • Independent Serial Ports: Four fully isolated serial ports supporting RS-232, RS-422, or RS-485 physical layers.
  • High Electrical Isolation: 2500 Vrms port-to-port and port-to-backplane signal isolation via digital RF modulation components.
  • Robust Ethernet Interface: Single 10/100 Mbps RJ45 port featuring 1500 Vrms electrical isolation and integrated broadcast storm resiliency.
  • Flexible Power Input: Accepts a wide input range of 10 to 36 VDC, suitable for standard industrial 24 VDC control panels.
  • Diagnostic Indicators: Front-panel LEDs provide immediate visual confirmation of power, module status, network activity, and serial transmission (TX/RX) status.

Applications

  • Integration of legacy Modbus RTU/ASCII power meters, flowmeters, and protection relays into modern Ethernet-based SCADA systems.
  • Substation automation where high electrical isolation is necessary to prevent ground loops and protect centralized controller CPUs.
  • Distributed water and wastewater monitoring setups requiring multi-point RS-485 serial networks linked to a centralized PLC over fiber or wireless Ethernet.

Technical Specifications

Manufacturer ProSoft Technology
Model Reference PLX31-MBTCP-MBS4
Power Supply Input 24 VDC nominal (10 to 36 VDC permitted)
Current Consumption 300 mA @ 24 VDC nominal (610 mA maximum @ 10 VDC)
Ethernet Port 1x 10/100 Base-T RJ45 connector, half/full-duplex auto-negotiation
Ethernet Isolation 1500 Vrms (50 to 60 Hz for 60 seconds)
Serial Interface Ports 4x isolated serial ports (RS-232, RS-422, or RS-485 configuration)
Serial Port Isolation 2500 Vrms signal isolation (UL 1577 rated, RF modulation media)
Operating Temperature -25 to 70 degC (-13 to 158 degF)
Storage Temperature -40 to 80 degC (-40 to 176 degF)
Relative Humidity 5% to 95% RH (non-condensing)
Shock Rating IEC 60068-2-27: 15G operational (11ms), 30G non-operational (18ms)
Vibration Rating IEC 60068-2-6: 5G @ 10 to 150 Hz
Dimensions (H x W x D) 13.67 x 5.05 x 11.13 cm
Shipping Weight 2.5 kg

Connections and Interfaces

Port / Terminal Block Interface Type Functional Assignment
Ethernet Port RJ45 Modbus TCP/IP Master (Client) / Slave (Server) connection
Serial Port 1 to 4 Combicon Terminal Modbus RTU/ASCII Master or Slave (RS-232, RS-422, or RS-485 configuration)
Power Terminal 3-Position Pluggable V+ (10 to 36 VDC), V- (DC Return), and Earth Ground

Empirical Engineering Insights

Alternative Models & Compatibility

The PLX31-MBTCP-MBS4 serves as a modernized replacement for older legacy gateways. When transitioning configuration profiles from previous-generation ProSoft modules, verify database memory mappings, as the internal database register structures may require offset realignment. Use the ProSoft Configuration Builder (PCB) software for smooth parameter migration.

Application Pitfalls & Engineering Notes

A common issue during multi-port commissioning is Modbus TCP/IP transaction timeouts caused by slower serial-side responses. Ensure that your Modbus TCP master poll timeout matches the longest potential serial round-trip time. When running RS-485 configurations with high slave counts or long cable distances, external 120-ohm termination resistors must be installed at both physical ends of the trunk to prevent signal reflections.

Commissioning & Wiring Tips

The four serial interfaces feature specialized 2500 Vrms digital isolation chips. To maintain this high level of isolation performance, never share common reference or shield lines between different isolated ports or external power sources. For noisy VFD environments, utilize double-shielded twisted-pair (STP) cabling for all serial trunks and tie the cable shields directly to the cabinet ground at a single, centralized point.

Installation Guidelines

CRITICAL WARNING: De-energize all power lines before attempting to install, wire, or remove the gateway module. Touching live electrical terminations can lead to severe equipment damage, electrical shock, or physical injury. Ensure the internal system ground terminal is properly bonded to a low-impedance earth ground path before applying DC power.
1
Mount the gateway securely to an approved 35 mm DIN rail inside a protective NEMA or IP54 electrical enclosure, allowing at least 2 inches of clearance at the top and bottom for natural convective cooling.
2
Configure the internal physical serial port jumpers (underneath the front cover) to choose between RS-232, RS-422, or RS-485 modes for each of the four serial ports.
3
Connect the isolated serial network cables to the corresponding pluggable Combicon terminal blocks, ensuring correct polarity of Transmit (TX) and Receive (RX) lines.
4
Connect the Ethernet network cable to the RJ45 port and apply nominal 24 VDC power to the power supply terminal block. Monitor the LED diagnostic indicators to confirm successful module initialization.

Can each serial port run on different communication settings?

Yes. Each of the four serial ports on this module is completely independent. You can configure individual baud rates, parity, stop bits, and physical modes (RS-232, RS-422, or RS-485) per port.

How do you set the IP address of this gateway?

The IP address is set using the ProSoft Configuration Builder (PCB) software over Ethernet, or via the ProSoft Discovery Service utility to detect and assign a static IP address to the module on the local network.

What software is needed to map Modbus TCP/IP registers to Modbus Serial?

No programming is required. Drag-and-drop configuration and custom register mapping are fully handled through ProSoft Configuration Builder (PCB), which is free to download.

Is external termination required for the RS-485 serial networks?

Yes. While the serial ports are isolated, they do not include internal software-selectable termination. For long cable lengths or high noise environments, external 120-ohm resistors must be used at the physical ends of the line.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
สหรัฐอเมริกา

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...