1 จาก 1

Siemens 6GK5774-1FY00-0TB0 SCALANCE W774-1 M12 EEC IWLAN Access Point

Siemens 6GK5774-1FY00-0TB0 SCALANCE W774-1 M12 EEC IWLAN Access Point

Only 3 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 6GK5774-1FY00-0TB0

  • Country of origin:เยอรมนี

  • Product Type: IWLAN Access Point

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 1800g

  • Dimensions: 1.0 cm x 1.0 cm x 1.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Description

This is a Siemens 6GK5774-1FY00-0TB0 SCALANCE W774-1 M12 EEC, an Industrial Wireless LAN (IWLAN) access point designed for reliable communication in demanding environments. The unit features a single radio interface supporting IEEE 802.11a/b/g/h/n standards across both 2.4 GHz and 5 GHz frequency bands, delivering a gross data rate of up to 300 Mbit/s. It includes an integrated 2-port switch with rugged M12 connectors and supports Power over Ethernet (PoE) for simplified installation. Power can also be supplied via a redundant 24 V DC input. With a conformal coating, an IP30 rating, and compliance with EN 50155, this device is engineered for transportation systems and other harsh industrial settings.

Features

  • Single radio interface with dual-band operation (2.4 GHz / 5 GHz).
  • Supports IEEE 802.11a/b/g/h/n wireless standards.
  • Achieves a gross data transmission rate of up to 300 Mbit/s.
  • Integrated 2-port Ethernet switch with M12 connectors (max. 100 Mbit/s).
  • Flexible power options with Power over Ethernet (PoE) and redundant 24 V DC input.
  • Conformal coating for enhanced protection against environmental factors.
  • Extended operating temperature range from -30 to +65 degC.
  • Advanced iFeatures can be enabled via an optional KEY-PLUG.
  • Supports WPA2/802.11i/e for secure wireless communication.

Applications

  • Onboard vehicle networks in trains, buses, and trams.
  • Trackside communication and railway infrastructure.
  • Mobile machinery, cranes, and automated guided vehicles (AGVs).
  • Industrial automation cells requiring robust wireless links.
  • Outdoor installations within suitable protective enclosures.

Technical Specifications

General Information
Product Type IWLAN Access Point
Model Number 6GK5774-1FY00-0TB0
Product Series SCALANCE W774-1 M12 EEC
PLM Product Phase Active
Wireless Communication
Wireless Standards IEEE 802.11a/b/g/h/n
Frequency Bands 2.4 GHz / 5 GHz
Gross Data Rate 300 Mbit/s
Radio Interfaces 1
Antenna Ports 2 x R-SMA
Security WPA2 / IEEE 802.11i/e
Wired Interfaces & Electrical
Ethernet Ports 2 x M12 (A-coded), integrated 2-port switch
Ethernet Speed Up to 100 Mbit/s
Power Supply Redundant 24 V DC
Power over Ethernet (PoE) Supported
Mechanical & Environmental
Ingress Protection IP30
Operating Temperature -30 to 65 degC
Special Features Conformal Coating
Compliance EN 50155
Logistics & Regulatory
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 1.0 cm x 1.0 cm x 1.0 cm
Shipping Weight 1.80 kg
Commodity Code 85176200
ECCN 5A002
Certification ID MSN-W1-M12-E2
Scope of Delivery Manuals on CD-ROM (English/German), M12 sealing caps

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Disconnect all power sources before installation or maintenance. Failure to de-energize the system can result in severe injury or death. This device must be installed by qualified personnel only, in accordance with all applicable electrical codes.

  1. 1 Verify package contents. Ensure the SCALANCE module, M12 sealing caps, and documentation are present before beginning installation.
  2. 2 Mount the access point securely to a stable surface or DIN rail within the control panel or enclosure. Ensure adequate clearance for cable routing and heat dissipation.
  3. 3 Connect the R-SMA antennas to the designated ports. Tighten connections to be finger-tight plus a quarter turn with an appropriate tool to ensure a secure RF link. Do not overtighten.
  4. 4 Terminate the M12 Ethernet cables for network connectivity. If using PoE, confirm the upstream switch or injector meets the device's power requirements.
  5. 5 If using a local power source, connect the redundant 24 V DC supply via the specified M12 A-coded connector, observing correct polarity.
  6. 6 Ensure the unit is properly grounded according to site and regulatory requirements to minimize the effects of electrical noise and ensure safety.
  7. 7 After all physical connections are secured and verified, re-apply power to the system and proceed with software configuration of the access point.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...