1 จาก 1

Weidmuller 8965410000 ACT20X-SDI-HDO-H-S ACT20X Series Valve Control Module

Weidmuller 8965410000 ACT20X-SDI-HDO-H-S ACT20X Series Valve Control Module

Only 10 item(s) left in stock
  • Manufacturer: Weidmuller

  • Product No.: 8965410000

  • Country of origin:เยอรมนี

  • Product Type: Valve Control Modules

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 117.2 mm x 22.5 mm x 113.6 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Operating as an intrinsically safe solenoid driver, the Weidmuller ACT20X-SDI-HDO-H-S controls valve systems, acoustic alarms, and indicators located in hazardous areas. This high-performance module provides galvanic isolation between the control system and the field devices, ensuring reliable signal transmission and robust explosion protection in demanding process environments.

Key Features

  • Intrinsically safe output (Ex ia IIC) designed for direct deployment in hazardous areas.
  • Integrated alarm relay output for immediate signaling of power loss or internal device errors.
  • FDT/DTM software-based configuration for precise parameterization and diagnostic monitoring.
  • Compact 22.5 mm DIN-rail housing to optimize space within electrical control panels.
  • Secure screw connection technology to guarantee long-term, vibration-resistant wiring.

Industrial Applications

  • Chemical and petrochemical processing plants with explosive atmospheres (Zone 0, 1, and 2).
  • Oil and gas extraction, refining, and distribution facilities.
  • Pneumatic and hydraulic solenoid valve control in hazardous process loops.
  • Industrial signaling, beacon control, and acoustic alarm integration.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Weidmuller
Article Number (SKU) 8965410000
Model Designation ACT20X-SDI-HDO-H-S
Product Type Valve Control / Solenoid Driver
Number of Channels 1
Supply Voltage Range 19.2 to 31.2 V DC
Power Consumption <= 2.5 W
Step Response Time <= 10 ms
Alarm Functionality No supply voltage, Device error
Alarm Relay Output 1 NC contact
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current (Alarm) <= 0.5 A AC / 0.3 A DC
Configuration Interface FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Temperature -20 to +60 degC
Ambient Humidity 0 to 95% (non-condensing)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Net Weight 170 g
Shipping Weight (Calculated) 1.2 kg
Country of Origin Germany

Connections and Interfaces

Terminal Block / Pin Functional Assignment
Terminals 11, 12 Digital Control Input (Safe Area)
Terminals 13, 14 Alarm Relay Output (NC Contact)
Terminals 41, 42 Intrinsically Safe Solenoid Output (Hazardous Area, Ex ia)
Terminals 51, 52 Power Supply Input (19.2 to 31.2 V DC)

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-SDI-HDO-H-S is fully compatible with standard FDT/DTM frame applications such as Weidmuller WI-Manager. When replacing legacy ACT20X models, ensure that the configuration profile is exported and reloaded using the CBX200 USB interface cable to preserve specific safety loop parameters.

Application Pitfalls & Engineering Notes

When mounting multiple ACT20X modules side-by-side on a DIN rail, ensure cabinet ventilation maintains ambient temperatures below 60 degC. High-density packing without adequate airflow can lead to localized thermal stress. Always verify that the Ex-i output parameters (Uo, Io, Po) strictly match the electrical characteristics of the connected solenoid valve to maintain safety loop integrity.

Commissioning & Wiring Tips

Perform offline configuration via the front-panel port before mounting the unit onto the DIN rail. Ensure that intrinsically safe field wiring (hazardous area) is physically separated from non-intrinsically safe wiring (safe area) by a minimum distance of 50 mm, or utilize physical partitions in compliance with IEC/EN 60079-14 standards.

Installation Guidelines

CRITICAL WARNING:

Isolate all power sources before mounting, wiring, or configuring the device. Failure to de-energize the system prior to installation in hazardous areas can result in electrical arcing, leading to severe equipment damage, explosion, or personal injury.

1 Mount the module vertically onto a standard TS 35 DIN rail, ensuring secure mechanical latching.
2 Connect the intrinsically safe field device wiring to the Ex-designated terminals (Terminals 41 and 42).
3 Wire the control input, alarm relay, and the 24 V DC power supply to the safe-area terminals.
4 Connect the CBX200 USB cable to configure the alarm thresholds and operational parameters via FDT/DTM software.

How is the ACT20X-SDI-HDO-H-S module configured?

Configuration is performed using standard FDT/DTM software via a CBX200 USB interface cable connected to the front-panel port.

What is the purpose of the integrated alarm relay?

The alarm relay provides a normally closed (NC) contact that opens to signal a loss of supply voltage or an internal device error.

Can this module drive solenoid valves located in Zone 0?

Yes, the output circuit is rated intrinsically safe (Ex ia IIC), allowing direct connection to solenoid valves and indicators in Zone 0, 1, or 2.

What are the maximum switching limits for the alarm contact?

The alarm relay contact supports up to 125 V AC at 0.5 A or 110 V DC at 0.3 A.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Country of origin
เยอรมนี

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...