1 -ın, -in, -un, -ün (bağlama göre değişir) 1

Mitsubishi Electric FR-F840-01160-2-60 FR-F800 Series Inverter

Mitsubishi Electric FR-F840-01160-2-60 FR-F800 Series Inverter

Stokta sadece 10 adet kaldı
  • Üretici: Mitsubishi Electric

  • Ürün No.: FR-F840-01160-2-60

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Variable Frequency Drives

  • Ödeme: T/T, Western Union

  • Ağırlık: 41000g

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

Engineered to optimize centrifugal pump and fan efficiency across demanding industrial networks, the Mitsubishi Electric FR-F840-01160-2-60 Variable Frequency Drive delivers precision speed control within the high-performance FR-F800 Series. This unit features advanced energy-saving algorithms and robust hardware tailored for hostile atmospheres. The FR-F840-01160-2-60 carries a heavy-duty design rating of 55 kW, utilizing specialized protective circuit board coatings to extend its operational lifespan in corrosive or humid environments.

Key Technical Features

  • Coated Circuit Boards: Enhanced protection class featuring specialized PCB varnish conformal coating (indicated by the "-60" designation) and non-plated conductors to resist moisture and airborne contaminants.
  • Advanced Energy Saving: Built-in optimum excitation control algorithms continuously optimize motor flux, reducing energy consumption under variable torque loads.
  • Intelligent Load Diagnostics: Detects mechanical blockages, dry run states, or belt breakage by comparing operating torque signatures against pre-configured limit curves.
  • Dual-Channel Safety STO: Integrated Safe Torque Off (STO) inputs for compliant emergency stop performance without redundant external contactors.

Industrial Applications

  • Municipal Water Treatment: Precision pressure regulation for booster pumps, sewage aerators, and chemical dosing systems.
  • HVAC & Building Automation: Large-scale industrial chillers, cooling towers, and air handling units (AHUs).
  • Material Processing: Exhaust fans, ventilation blowers, and secondary pump loops in metallurgy and chemical manufacturing plants.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Code FR-F840-01160-2-60
Series Name FR-F800
Applicable Motor Capacity 55 kW
Rated Output Current 116 A
Output Rated Capacity 88 kVA
Input Voltage Phase / Freq Three-phase 380 to 500 V AC, 50 Hz / 60 Hz
Voltage Fluctuation Range 323 to 550 V AC, 50 Hz / 60 Hz
Frequency Fluctuation Range +/- 5 percent
Power Supply Capacity 107 kVA
IP Rating / Enclosure IP00 (Open Type, JEM1030)
Cooling System Forced Air Cooling
Country of Origin Japan
Unit Net Weight 41.0 kg
Shipping Weight (Calculated) 47.0 kg

Power Terminal Configurations

Terminal Designation Functional Assignment / Circuit Role
R/L1, S/L2, T/L3 Three-phase AC power input connections
U, V, W Three-phase variable frequency output to AC induction motor
P/+, PR DC Bus positive / connection to dynamic braking resistor
P/+, N/- DC Bus common link connection for regenerative converter configurations
Earth / Ground (PE) Chassis grounding terminal for electrical noise safety compliance

Alternative Models & Compatibility

Standard units in this catalog range carry a "-1" suffix for baseline industrial environments. The FR-F840-01160-2-60 features a "-2" region designator (equivalent to standard CA functional specification with embedded European/Chinese EMC filter standards) combined with the protective "-60" suffix. It is directly backwards-compatible in mechanical sizing with standard FR-F740 models of equivalent physical footprint, though parameters must be translated via FR Configurator2 software prior to operational start.

Application Pitfalls & Engineering Notes

Because this unit is an IP00 open-type chassis, it is susceptible to direct environmental ingress if left unhoused. Mounting inside an IP54 or higher rated MCC panel is required. The drive dissipates approximately 1.5 kW of heat under full-load operation. Ensure your panel's thermal engineering supports forced ventilation calculation rates of at least 250 cubic meters per hour to avoid over-temperature trips.

Commissioning & Wiring Tips

Keep analog control lines completely separated from high-energy output cables. Ground shielding for terminal connections must terminate at the grounding plate immediately adjacent to the VFD chassis. Do not short the SD terminal (control common) to the safety earth (PE) ground, as this initiates ground loops that cause noise-induced controller resetting.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

De-energize all primary supply lines before removing the terminal block covers. Allow a minimum of 10 minutes for internal DC bus capacitors to fully discharge. Always verify that voltage between terminals P/+ and N/- is below 50 V DC with a calibrated voltmeter before executing any physical wiring or maintenance steps.

1
Mounting Alignment

Mount the chassis vertically on an unpainted, flat metal backplate to ensure continuous electrical ground continuity. Maintain 100 mm clearances above and below the cooling vents.

2
High-Power Conduit Separation

Route AC input (R/L1, S/L2, T/L3) and output motor connections (U, V, W) through separate metallic conduits to prevent cross-talk and high-frequency interference.

3
Control Cable Shield Grounding

Ground all control shields directly at the cable clamp. Terminate control signals on separate paths from power wiring. Avoid connecting terminal SD to structural PE ground.

Loading product navigation…

What does the -60 suffix signify on this specific drive?

The -60 suffix denotes that the printed circuit boards have specialized conformal coatings and use non-plated conductors, protecting the sensitive interior circuitry from moisture, corrosive gases, and harsh environments.

What is the physical protective rating of this drive housing?

This drive is an open-type chassis rated at IP00. It must be installed inside a secondary protective enclosure, such as an IP54-rated control cabinet, to defend against dust and water ingress.

Does this model include a built-in EMC filter?

Yes, the regional symbol '2' represents the CA specification model, which comes with an integrated European and Chinese standard EMC filter to minimize electromagnetic feedback into your main power lines.

What size motor is compatible with this frequency inverter?

This drive is designed to control three-phase AC induction motors with a power rating of up to 55 kW and a continuous output rating of 116 A.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma günleri işlenir ve teslim edilir (resmi tatiller hariç).


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının,...

FBD PLC Programlamada Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...