1 -ın, -in, -un, -ün (bağlama göre değişir) 3

Mitsubishi Electric GCU08BB-130 80173-109-01-2 GU-G08 Tristör Ünitesi

Mitsubishi Electric GCU08BB-130 80173-109-01-2 GU-G08 Tristör Ünitesi

Stokta sadece 5 adet kaldı
  • Üretici: Mitsubishi Electric

  • Ürün No.: GCU08BB-130 80173-109-01-2

  • Menşei ülke:Amerika Birleşik Devletleri

  • Ürün Türü: Tiristör Ünitesi

  • Barkod: 8537101190

  • Ödeme: T/T, Western Union

  • Ağırlık: 1100g

  • Boyutlar: 48 mm x 208 mm x 250 mm (H x W x D)

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Miktar
Tüm detayları görüntüle

Description

The Mitsubishi Electric GCU08BB-130 is a high-power symmetrical Gate Commutated Turn-off (GCT) thyristor unit integrated with a dedicated GU-G08 gate driver board assembly, engineered specifically for high-power inverter use. This industrial press-pack type device features an optimized co-axial configuration where the GCT semiconductor and the gate driver are interconnected directly to achieve low-inductance gate commutation and robust noise immunity. The unit provides critical power management with a repetitive peak off-state voltage of 6500V and a repetitive controllable on-state current of 800A. Bearing the manufacturer identification 80173-109-01-2, the GCU08BB-130 delivers dependable solid-state switching for current source inverters, DC choppers, induction heaters, and DC to DC converters.

Features

  • Symmetrical GCT device layout with an integrated GU-G08 gate driver board for direct, low-inductance control.
  • Four built-in diagnostic LED indicators providing real-time operational feedback: POWER SUPPLY OK (Green), G-K OK (Green), GATE ON (Yellow), and GATE OFF (Red).
  • Integrated fiber optic control interface utilizing dedicated transmitter and receiver nodes to ensure electrical isolation and high immunity against electromagnetic interference (EMI).
  • Dual on-board test points (GATE TEST POINT and CATHODE TEST POINT) for straightforward field diagnostics and voltage verification.
  • High-voltage press-pack structure offering balanced thermal dissipation across the double-sided cooling surfaces under heavy mechanical clamping.

Applications

  • Current source inverters
  • DC choppers
  • Induction heaters
  • DC to DC converters

Technical Specifications

Electrical Ratings (GCT Part)

Parameter Symbol Conditions Rating / Limit Unit
Repetitive peak reverse voltage VRRM 6500 V
Non-repetitive peak reverse voltage VRSM 6500 V
Repetitive peak off-state voltage VDRM Gate driver energized 6500 V
Non-repetitive peak off-state voltage VDSM Gate driver energized 6500 V
Long term DC stability voltage V(LTDS) Gate driver energized, lambda = 100 Fit 3600 V
RMS on-state current IT(RMS) Applied for all condition angles 520 A
Average on-state current IT(AV) f = 60Hz sinewave, theta = 180 degrees, Tt = 62 degC 330 A
Repetitive controllable on-state current ITQRM VDM = 3/4 VDRM, VD = 3000V, LC = 0.3 uH, Tj = 25/125 degC 800 A
Surge on-state current ITSM One half cycle at 60Hz, Tj = 125 degC start 4.8 kA
Current-squared, time integration I2t One half cycle at 60Hz, Tj = 125 degC start 9.6 x 10^4 A2s
Critical rate of rise of on-state current dit/dt VD = 3000V, IT = 800A, Cs = 0.1 uF, Rs = 10 Ohm, Tj = 25/125 degC, f = 60Hz 1000 A/us
Critical rate of rise of reverse recovery current dir/dt IT = 800A, VA = 3000V, Tj = 25/125 degC, Cs = 0.1 uF, Rs = 10 Ohm 1000 A/us
Peak forward gate power dissipation PFGM 5 kW
Peak reverse gate power dissipation PRGM 17 kW
Average forward gate power dissipation PFG(AV) 100 W
Average reverse gate power dissipation PRG(AV) 120 W
Peak forward gate voltage VFGM 10 V
Peak reverse gate voltage VRGM 21 V
Peak forward gate current IFGM 500 A
Peak reverse gate current IRGM 800 A

Electrical Characteristics (GCT Part)

Parameter Symbol Conditions Min Typ Max Unit
On-state voltage VTM IT = 400A, Tj = 125 degC 5.5 V
Repetitive peak reverse current IRRM VRM = 6500V, Tj = 125 degC 250 mA
Repetitive peak off-state current IDRM VDM = 6500V, Tj = 125 degC, Gate driver energized 100 mA
Reverse gate current IGRM VRG = 21V, Tj = 125 degC 40 mA
Critical rate of rise of off-state voltage dv/dt VD = 3000V, Tj = 125 degC, Gate driver energized (Expo. wave) 3000 V/us
Turn-on time tgt Tj = 125 degC, IT = 800A, VD = 3000V, Cs = 0.1 uF, Rs = 10 Ohm 5 us
Turn-on delay time td Tj = 125 degC, IT = 800A, VD = 3000V, Cs = 0.1 uF, Rs = 10 Ohm 1 us
Turn-on switching energy Eon IT = 400A, VD = 3000V, di/dt = 1000A/us, Cs = 0.1 uF, Rs = 10 Ohm, Tj = 125 degC 0.6 J/P
Storage time ts IT = 800A, VDM = 3/4 VDRM, VD = 3000V, Cs = 0.1 uF, Rs = 10 Ohm, Tj = 125 degC 3 us
Turn-off switching energy Eoff IT = 400A, VDM = 4000V, VD = 3000V, Cs = 0.1 uF, Rs = 10 Ohm, Tj = 125 degC 2.3 J/P
Reverse recovery charge QRR VA = 3000V, IT = 400A, di/dt = 1000A/us 1800 uC
Reverse recovery energy Erec Cs = 0.1 uF, Rs = 10 Ohm, Tj = 125 degC 4.4 J/P
Gate trigger current IGT VD = 24V, RL = 0.1 Ohm, Tj = 25 degC 0.5 A
Gate trigger voltage VGT DC method 1.5 V

Gate Driver Board Assembly (GU-G08 Part)

Parameter Symbol Conditions Min Typ Max Unit
Power supply voltage VGIN DC power supply input via Phoenix plug 19 20 21 V
Gate power consumption PGIN IT = 420Arms, f = 780Hz, duty = 0.33 35 W
Delay time of on gate current tfd Ta = 25 degC 3.0 us
Delay time of off gate current trd Ta = 25 degC 3.0 us

Mechanical and Environmental Data

Parameter Symbol Conditions Min Typ Max Unit
Mounting force FM Required compression clamping 11.1 13 15.8 kN
Weight Base module mass 1100 g
Pole piece diameter GCT component mating profile (±0.2mm) 47 mm
Housing thickness GCT component thickness (±0.5mm) 26 mm
Junction operating temperature Tj Continuous operation -10 125 degC
Storage temperature Tstg Ambient environment -10 60 degC
Ambient operation temperature Ta Local enclosure air (Recommended <= 40 degC) -10 60 degC
Junction to Fin thermal resistance Rth(j-f) Double-sided cooling configuration 0.025 K/W

Connections/Interfaces

Interface Component Assignments

Interface / Connector Name Component / Type Identifier Function
20V Power Supply Input Phoenix Contact MSTB2.5/2-G-5.08AU Main 20VDC power supply input for the gate driver board
Fiber Optic Input Agilent HFBR-2521 Receiver port for external optical control pulse lines
Fault Signal Output Agilent HFBR-1521 Transmitter port for optical feedback and driver status tracking
Gate Test Point On-board Terminal Pin Physical point for measuring gate potential
Cathode Test Point On-board Terminal Pin Physical point for measuring cathode potential

Installation Guidelines

  • Clamping Pressure Control: The press-pack assembly requires a strict mechanical force within 11.1 kN to 15.8 kN (Target: 13 kN). Improper mounting force degrades the internal interface thermal resistance and risks electrical failure under high current loads.
  • Control Power Parameters: Deliver a clean DC voltage profile between 19V and 21V directly to the 2-pin Phoenix plug header. Ensure power cabling satisfies continuous current demands without dropping below 19V during high-frequency gate charging.
  • Optical Data Link Rules: Ensure the fiber optic cables securely seat inside the Agilent HFBR-2521 and HFBR-1521 sub-assemblies. Maintain bend radiuses above the minimal mechanical thresholds to block light-attenuation errors.
  • Thermal Interface Execution: Coat the heatsink poles smoothly and evenly with high-performance thermal grease. The total thermal loop resistance from junction to fin must remain bound under 0.025 K/W.
  • Screw Clearance Safety: Limit the engagement depth of matching screws penetrating the thermal blocks or heatsink directly to between 6 mm and 8 mm to avoid distortion of the housing or board stress.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Mitsubishi Electric GCU08BB-130 80173-109-01-2 GU-G08 Tristör Ünitesi

What is the function of the GU-G08 assembly on this device?

The GU-G08 assembly serves as the dedicated integrated gate driver board, responsible for receiving fiber optic control inputs and executing high-speed current commutation to switch the GCT thyristor.

What are the specific designations of the onboard LED indicators?

The board features four LEDs: LED4 indicates Power Supply OK (green), LED3 indicates G-K OK (green), LED2 indicates Gate ON (yellow), and LED1 indicates Gate OFF (red).

What is the proper mounting force needed for installation?

The unit must be mounted using a press compression force between 11.1 kN and 15.8 kN, with a nominal configuration setting of 13 kN.

Which fiber optic components are utilized for signal transmission?

The device utilizes an Agilent HFBR-2521 receiver for the incoming control signal and an Agilent HFBR-1521 transmitter for outputting the status/fault signal.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

Akışkan Güç Sistemlerinin Yerini Almak İçin Tasarlanmış Elektrikli Aktüatörler: Pratik Bir Endüstriyel Otomasyon Rehberi

Bu makale, SMC’nin e-Actuator serisi gibi entegre elektrikli aktüatörlerin, geleneksel pnömatik ve hidrolik sistemlerin yerini alarak endüstriyel hareket kontrolünü nasıl dönüştürdüğünü...

Endüstriyel Otomasyon Uygulamaları için OpenPLC Kullanarak Matematiksel İşlemler

Bu makale, PLC sistemlerinin endüstriyel otomasyonda toplama, çıkarma, çarpma, bölme, mod alma ve üs alma gibi temel matematiksel işlemleri nasıl gerçekleştirdiğini açıklar. Bu fonksiyon bloklarının...

Gelişmiş Boolean Mantığı ile FBD PLC Programlama: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robot tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...