Description

Integrating Modbus TCP/IP communications directly into Rockwell Automation ControlLogix systems, the ProSoft MVI56-MNETR provides a specialized high-performance network interface utilizing a reduced data block structure. This module operates as an in-chassis slot solution, enabling ControlLogix processors to interface seamlessly with Modbus TCP/IP-compatible field instruments, SCADA systems, and programmable controllers. Designed specifically for architectures with constrained memory mapping or remote I/O limitations, the reduced data block configuration limits the backplane I/O transfer size to 240 words of input and 240 words of output data, making it highly compatible with remote I/O racks over ControlNet or EtherNet/IP adaptors.

Features

  • Reduced Data Block Structure: Limits I/O data transfers to 240 words input/240 words output to support remote rack installations.
  • Multi-Protocol Flexibility: Concurrently supports both Modbus TCP/IP Client (Master) and Server (Slave) configurations.
  • High Isolation Security: 1500 V rms electrical isolation protects the ControlLogix backplane from external network transient faults.
  • Optimized Diagnostic LEDs: Front-panel indicators provide real-time status updates for module operation, backplane transfer, and serial/Ethernet port activity.
  • Network Resiliency: Integrated broadcast storm protection mitigates network degradation under high-volume ARP frame scenarios.

Applications

  • Remote I/O rack communication over ControlNet or EtherNet/IP.
  • SCADA and HMI integration across plant networks.
  • Substation automation and power monitoring network connections.
  • Interfacing with variable frequency drives, flow meters, and external PLCs.

Technical Specifications

Parameter Specification
Manufacturer ProSoft Technology
Model Series MVI56 ControlLogix Platform
Backplane Current Draw 800 mA at 5 Vdc; 3 mA at 24 Vdc
Operating Temperature 0 degC to 60 degC (32 degF to 140 degF)
Storage Temperature -40 degC to 85 degC (-40 degF to 185 degF)
Relative Humidity 5% to 95% (non-condensing)
Vibration Resistance 5 g from 10 Hz to 150 Hz
Shock Operational 30 g operational; 50 g non-operational
Ethernet Port 10/100 Base-T RJ45 Connector
Electrical Isolation 1500 V rms at 50 to 60 Hz for 60 s (IEC 60950)
Broadcast Storm Resiliency Less than or equal to 5000 ARP frames-per-second
Net Weight 0.45 kg
Shipping Weight (Calculated) 1.50 kg
Package Dimensions (Calculated) 25.0 cm x 20.0 cm x 8.0 cm

Connections and Interfaces

Interface Port Description / Function
Ethernet Port (RJ45) Primary 10/100 Mbps Modbus TCP/IP connection. Utilizes Cat5e or Cat6 cabling.
CFG Port (RJ45) Configuration port. Interfaces via RJ45 to DB-9M connection for diagnostics and firmware utility software setup.

Empirical Engineering Insights

Alternative Models & Compatibility

It is vital to distinguish the MVI56-MNETR from the standard MVI56-MNET. The MVI56-MNET utilizes a larger 5000-word block size, which is unsupported by several common remote I/O network adapters. If your system architecture places the communication interface in a remote rack connected via ControlNet (e.g., 1756-CNB/CN2) or EtherNet/IP (e.g., 1756-ENBT/EN2T), the "R" (Reduced Data Block) variant is mandatory to prevent connection sizing faults.

Application Pitfalls & Engineering Notes

When configuring large networks, ensure the broadcast traffic does not exceed the hardware limit of 5000 ARP frames-per-second. Networks shared with enterprise data or unmanaged switches often suffer from high broadcast traffic, which can trigger the internal safety isolation of the MVI56-MNETR's ethernet controller, causing brief, intermittent offline faults. Always isolate industrial control paths onto distinct virtual networks (VLANs) or managed switches.

Commissioning & Wiring Tips

Initial configuration requires ProSoft Configuration Builder (PCB) software. Connect via the provided RJ45-to-DB9 cable to the configuration serial port prior to system insertion if your default IP network segment is different. Ensure standard RS-232 serial parameters are matched on the configuration computer to establish stable firmware terminal access.

Installation Guidelines

CRITICAL WARNING: electrical discharge hazard

Remove all system operational power from the ControlLogix chassis before inserting or removing the MVI56-MNETR interface. Inserting or removing the card while the backplane is energized can cause irreversible logical disruption to the PLC processor or damage the backplane contact connector pins.

1 Ensure the ControlLogix system is de-energized.
2 Align the module circuit card with the plastic guides of the target slot in the ControlLogix chassis.
3 Firmly slide the module inward until it seats securely into the chassis backplane.
4 Secure the top and bottom chassis tabs on the module front-plate.
5 Connect the shielded RJ45 Ethernet communication cable to the primary ports and power on the chassis.
Loading product navigation…

What is the difference between the MVI56-MNET and MVI56-MNETR?

The MVI56-MNETR is the 'Reduced Data Block' version. It uses a maximum configuration of 240 input and 240 output words to communicate through standard backplanes. This enables the module to be utilized in remote I/O racks where network adaptors limit larger data block configurations.

Can the module operate as both a Modbus TCP/IP Client and Server concurrently?

Yes, the MVI56-MNETR interface supports simultaneous operations, allowing it to act as both a Modbus Client (Master) requesting data and a Modbus Server (Slave) responding to command requests on the network.

Is software required to configure the interface parameters?

Yes, configuration requires the free ProSoft Configuration Builder (PCB) software tool. Configuration files are downloaded to the module via the RS-232 serial configuration port using the supplied RJ45-to-DB9 cable.

What happens if Ethernet broadcast storm activity exceeds 5000 frames per second?

The module contains hardware protection that can drop or limit packets when broadcast frames exceed this limit to prevent module locking, ensuring backplane communications remain running.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Birleşik Devletleri

Son Görüntülenen Ürünler

Teknik bilgi

FBD PLC Programlama ile Gelişmiş Boolean Mantığı: Temel Mantığın Ötesinde Pratik Endüstriyel Uygulamalar

Makale, temel AND, OR ve NOT işlemlerinin ötesinde PLC programlamada kullanılan birkaç gelişmiş Boolean mantık fonksiyonunu açıklar. Doğruluk tabloları, çoklayıcılar, darbe üreteçleri ve Schmitt...

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...