1 / 1

Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Stokta sadece 10 adet kaldı
  • Üretici: Weidmuller

  • Ürün No.: 8965420000

  • Menşei ülke:Almanya

  • Ürün Türü: Intrinsically Safe Valve Drivers

  • Ödeme: T/T, Western Union

  • Ağırlık: 1200g

  • Boyutlar: 117.2 mm x 22.5 mm x 113.6 mm

  • Gönderim limanı: Xiamen

  • Garanti: 12 ay

Adet
Tüm ayrıntıları görüntüle

Facilitating the safe control of intrinsically safe valves in hazardous environments, the Weidmuller 8965420000 (ACT20X-2SDI-2HDO-S) provides reliable signal isolation and switching. This dual-channel valve control module acts as an isolated barrier, translating control signals from the safe area into intrinsically safe outputs to drive solenoids, valves, and acoustic alarms located in Ex zones.

Key Features

  • Dual-Channel Isolation: Supports two independent channels for space-saving, high-density cabinet layouts.
  • Integrated Diagnostics: Built-in alarm function detects and reports supply voltage loss and internal device errors.
  • Software Configurable: Fully compatible with FDT/DTM software for precise parameter adjustment and monitoring.
  • Secure Connections: Equipped with robust screw terminals to ensure vibration-resistant field wiring.
  • Compact Profile: 22.5 mm housing width optimizes DIN-rail space in control enclosures.

Industrial Applications

  • Oil & Gas Refineries: Actuation of intrinsically safe solenoid valves in hazardous processing zones.
  • Chemical Processing: Safe signal transmission and isolation for chemical dosing and distribution systems.
  • Pharmaceutical Manufacturing: Control of pneumatic and hydraulic valves in explosive dust or gas atmospheres.
  • Water & Wastewater Treatment: Isolated valve control in wet wells and chemical treatment areas.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Weidmuller
Article Number (SKU) 8965420000
Model Designation ACT20X-2SDI-2HDO-S
Product Type Intrinsically Safe Valve Control / Solenoid Driver
Number of Channels 2
Supply Voltage Range 19.2 to 31.2 V DC
Power Consumption <= 3.1 W
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current <= 0.5 A AC / 0.3 A DC
Step Response Time 10 ms
Configuration Method FDT/DTM software
Connection Type Screw connection
Operating Humidity 0 to 95% (non-condensing)
Protection Degree IP20
Net Weight 0.180 kg
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Shipping Weight (Calculated) 1.2 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-2SDI-2HDO-S is highly compatible with standard DCS and PLC digital output cards. When integrating this module into existing systems configured with older ACT20 series units, ensure that the FDT/DTM frame application is updated to the latest device description files to prevent communication errors during setup.

Application Pitfalls & Engineering Notes

When mounting multiple units side-by-side on a DIN rail, ensure the cabinet's thermal management system is active. Under maximum continuous current loads (0.5 A AC / 0.3 A DC), heat dissipation within high-density enclosures can rise. Maintain a minimum clearance or use active ventilation if the ambient temperature inside the panel consistently exceeds 45 degC.

Commissioning & Wiring Tips

Always maintain strict physical separation between the blue intrinsically safe (Ex-i) field wiring and the non-intrinsically safe supply/alarm connections. Mixing these routing paths violates hazardous area compliance. Use shielded cabling for the control signals to minimize high-frequency noise interference in high-transient environments.

Installation Guidelines

CRITICAL WARNING

Isolate and de-energize all power sources before mounting, wiring, or configuring this module. Ensure the surrounding atmosphere is verified as non-hazardous (gas-free) before opening any protective enclosures or adjusting field connections.

1

Snap the module securely onto a standard TS 35 DIN rail, ensuring the grounding spring makes solid contact with the rail.

2

Connect the 19.2 to 31.2 V DC power supply to the designated non-Ex power terminals.

3

Wire the intrinsically safe valve/solenoid field devices to the blue Ex-i screw terminals, keeping the cables physically isolated from power lines.

4

Connect the alarm relay outputs to your supervisory PLC or safety system to monitor for voltage loss or device faults.

Loading product navigation…

What software is required to configure the ACT20X-2SDI-2HDO-S?

The module is configured using standard FDT/DTM software, which allows for precise parameter adjustments, diagnostic monitoring, and channel setup.

Can this module be used in explosive atmospheres?

Yes, the module is designed as an intrinsically safe (Ex-i) barrier, allowing it to safely interface with solenoids and valves located in hazardous areas.

What diagnostic functions are integrated into the 8965420000?

It features an integrated alarm function that triggers a relay output in the event of a supply voltage loss or an internal device error.

What is the step response time of this valve control module?

The module features a fast step response time of less than or equal to 10 milliseconds, ensuring rapid valve actuation.

Küresel Ekspres Kargo

  • Standart Teslimat: DHL, FedEx ve UPS ile 4-6 iş günü.
  • Hızlı Gönderim: Saat 14:00 (GMT+8) öncesi verilen stoktaki siparişler aynı gün gönderilir.
  • Dünya Çapında Hizmet: Suudi Arabistan ve BAE'ye hızlı teslimat dahil 150'den fazla ülkeye hizmet veriyoruz.

İadeler ve Garanti

  • 30 Günlük Garanti: Stokta bulunan ürünler, orijinal, fabrika mühürlü ambalajında iade kabul edilir.
  • 12 Aylık Garanti: Her endüstriyel bileşen profesyonel teknik garantimizle desteklenmektedir.

Siparişler Pazartesi-Cuma (resmi tatiller hariç) işlenir ve teslim edilir.


Tam uygunluk, stok yenileme ücretleri ve uluslararası iade detayları için lütfen resmi sayfamızı inceleyin İade ve Geri Ödeme Politikası .

TECHNICAL SPECIFICATIONS

Country of origin
Almanya

Son Görüntülenen Ürünler

Teknik bilgi

PLC Programlamada Boolean Mantığı: FBD Mantık Kapılarını Anlamak

Boolean mantığı her PLC programının temelidir. Basit makine kontrollerinden karmaşık endüstriyel otomasyon sistemlerine kadar, mantık kapıları kontrolörlerin değişen girişlere ve çalışma koşullarına...

Endüstriyel Güvenlik Duvarları ve OT Ağ Segmentasyonu İçin Derinlemesine Rehber

Endüstriyel güvenlik duvarları, PLC, DCS ve SCADA ağlarını segmentasyon, giriş/çıkış kontrolü ve IEC 62443 prensipleriyle uyumlu IDS/IPS entegrasyonu yoluyla koruyarak OT siber güvenliğinde kritik...

Robotik Tutucular Rehberi: Hassas İşlemeden Ağır Hizmet Otomasyonuna

Modern robotik tutucular, geleneksel mekanik çenelerin ötesine geçiyor. Geckoya ilham veren yapışkan sistemlerden yumuşak gıda sınıfı tutuculara ve yapay zeka destekli depo araçlarına kadar gelişmiş...

Geçmişe Dönüş: Erken Elektrik Motorları Yeraltı Madenciliğini Nasıl Değiştirdi?

Halatla çalışan DC kompresörlerden bataryalı maden arabalarına kadar, erken madencilik faaliyetleri endüstriyel elektrifikasyonda bir dönüm noktası oldu. Bu makale, elektrik motorlarının modern...

Factory I/O: Endüstriyel Otomasyon Eğitimi için Modern Bir PLC Simülasyon Aracı

Factory I/O, öğrenciler, mühendisler ve bakım ekipleri için sürükleyici 3D endüstriyel simülasyonlar sunarak PLC eğitimini dönüştürüyor. Platform, teori ile gerçek dünya otomasyon uygulamaları...

CMZ Servo Sürücüsünde Tek Eksenli Hareket Döngülerinin Programlanması

Bu eğitim, bir CMZ SBD servo sürücüsündeki dahili PLC işlevselliğinin, harici bir PLC olmadan homing mantığı, konum kontrolü ve döngüsel eksen hareketi dahil olmak üzere bağımsız hareket...