1 of 3

1771-IFE Allen-Bradley PLC-5 Analog Input Module (16-Channel)

1771-IFE Allen-Bradley PLC-5 Analog Input Module (16-Channel)

Only 5 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: Allen Bradley 1771-IFE

  • Country of origin:United States

  • Product Type: Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 2.9cm x 19.3cm x 25.4cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview and Analog Data Acquisition

The 1771-IFE (1771IFE) is a high-density, intelligent analog input module belonging to the legendary Allen-Bradley PLC-5 series. Designed for precision data acquisition in heavy industrial environments—such as oil refineries, wastewater treatment plants, and steel mills—the module provides up to 16 single-ended or 8 differential inputs. It is engineered to convert continuous analog signals (voltage or current) into digital values that can be processed by the PLC-5 processor. The 1771-IFE is a cornerstone for monitoring critical process variables like pressure, flow, temperature, and level, offering a robust hardware solution that has maintained its reliability in the field for decades.

Hardware Architecture and Signal Interfacing

The 1771-IFE utilizes a modular chassis-based design and occupies a single slot in the 1771 I/O rack. It interfaces with the PLC backplane through block transfer programming, ensuring high-speed data updates without overloading the processor's discrete I/O scan.

  • Configurable Input Ranges: The module is highly versatile, supporting a wide array of signal types including 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC, and -10 to +10 VDC, as well as 4 to 20 mA current loops (using external shunt resistors).

  • A/D Conversion: Features a 12-bit Analog-to-Digital converter, providing a resolution of 4096 counts, which ensures high granularity for sensitive process control.

  • Input Filtering: Includes hardware-based low-pass filtering to suppress high-frequency noise and 50/60 Hz electrical interference common in industrial motor control centers.

  • Isolation Logic: Provides optical isolation between the analog input circuitry and the backplane logic, protecting the PLC processor from external field transients and ground loops.

Technical Specifications

Specification Details
Model 1771-IFE
Manufacturer Allen-Bradley / Rockwell Automation
Input Channels 16 Single-ended or 8 Differential
Resolution 12-bit (0 to 4095)
Voltage Ranges 0 to 5V, 1 to 5V, 0 to 10V, +/- 10V
Current Ranges 4 to 20 mA (With 249 Ohm resistor)
Conversion Type Successive Approximation
Backplane Current 750 mA @ 5 VDC
Operating Temp 0 to 60 Celsius
Isolation 1500 VAC (Continuous)
Shipping Weight 1.5 kg

Integrated Technical FAQ

How do I configure the module for 4 to 20 mA current inputs?

The 1771-IFE is natively a voltage-sensing module. To measure 4 to 20 mA, you must install a precision 249 Ohm shunt resistor across the input terminals and configure the software range for 1 to 5 VDC.

What is the difference between Single-Ended and Differential wiring?

Single-ended wiring (16 channels) uses a common ground for all inputs and is suitable for signals with a shared reference. Differential wiring (8 channels) uses two leads per signal to cancel out common-mode noise, making it the preferred choice for long cable runs in electrically noisy areas.

How does "Block Transfer" (BTW/BTR) affect module operation?

Unlike discrete I/O, analog data is too large for a single scan. You must use Block Transfer Write (BTW) to send configuration data (ranges, filters) to the module and Block Transfer Read (BTR) to pull the digitalized analog values into the PLC-5 data table.


Engineering & Installation Protocols

  • Wiring Arm Configuration: Use the 1771-WG wiring arm to allow for module replacement without disconnecting field wiring. Ensure that all terminal screws are tightened to 0.9 Nm to prevent signal drift caused by loose connections.

  • Shielding Strategy: Always use twisted-pair shielded cable for analog signals. Connect the shield at the PLC-5 chassis ground only; do not ground the shield at the sensor end to avoid creating ground loops that can cause significant measurement offsets.

  • Calibration Cycle: While the 1771-IFE is factory calibrated, it is recommended to perform a field calibration check every 12 months using a high-precision signal generator to account for component aging and environmental drift.

Engineering Advantages

The 1771-IFE remains a staple in legacy migration and maintenance strategies. Its high-density 16-channel capacity allows for significant I/O concentration, reducing the number of chassis slots required for large-scale monitoring. The module's diagnostic capabilities—including "Out of Range" bit detection—provide immediate feedback to the control logic, allowing for automated fail-safe routines in the event of a sensor failure or wire break, thereby enhancing overall plant safety and uptime.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...