Bently Nevada 129478-01 yuqori kuchlanishli doimiy tok quvvat kirish moduli
SKU 129478-01
In stock
No reviews
12-month warranty
Free returns within 30 days
Manufacturer:
Bently Nevada
Product No.:
129478-01
Country of origin:United States
Product Type:
Yuqori DC quvvat kiritish moduli
Barcode:
8537101190
Payment:
T/T, Western Union
Weight:
340g
Dimensions:
120,7 mm x 25,4 mm x 114,3 mm (B x W x Ch)
Shipping port:
Xiamen
Warranty:
12 months
Tavsif
Bently Nevada 129478-01 yuqori kuchlanishli doimiy tok quvvat kirish moduli (PIM) bo‘lib, mashinalarni himoyalash tizimida quvvat taqsimotiga mo‘ljallangan. Modul 3500/15 quvvat ta’minoti tizimidagi tegishli 129486-01 yuqori kuchlanishli doimiy tok quvvat ta’minoti modulining bevosita orqasida joylashadigan, balandligi yarim o‘lchamli maxsus orqa karta hisoblanadi. U 88 dan 140 Vdc gacha bo‘lgan kirish kuchlanishini qabul qiladi va mashinalarni monitoring hamda himoyalash apparaturasini quvvatlash uchun quvvatni ichki stend quvvat shinasi arxitekturasi orqali yo‘naltiradi. Modul kirishdagi saqlagich himoyasiga ega: ortiqcha kuchlanish holatida quyi oqimdagi komponentlarni himoyalash uchun saqlagich uziladi, past kuchlanish holatlari esa modulga zarar yetkazmaydi.
Funksiyalar
88 dan 140 Vdc gacha bo‘lgan kirish kuchlanishi diapazonini qabul qiladi
Tegishli quvvat ta’minoti modulining bevosita orqasidagi balandligi yarim o‘lchamli orqa uyaga o‘rnatiladi
Ortiqcha kuchlanishdan himoyalash uchun integratsiyalangan kirish saqlagichi tizimiga ega
To‘liq 3500 stendi uchun tok sarfini maksimal 2.5 A gacha qo‘llab-quvvatlaydi
Qo‘llanilishi
Bently Nevada 3500 Series mashinalarni himoyalash tizimlari
Sanoat mashinalarining holatini monitoring qilish tizimlari
Zaxira va asosiy quvvat kirishini taqsimlash qurilmalari
Texnik xususiyatlar
Parametr
Xususiyat
Ishlab chiqaruvchi
Bently Nevada
Model
129478-01
Modul turi
Yuqori kuchlanishli doimiy tok quvvat kirish moduli (PIM)
Tizim seriyasi
3500/15
Kirish kuchlanishi
88 dan 140 Vdc gacha
To‘liq stenddagi tok sarfi
Maksimal 2.5 A
Himoya
Ortiqcha kuchlanishda saqlagich uziladi; past kuchlanish PIMga zarar yetkazmaydi
O‘lchamlari (B x E x Ch)
120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in)
Og‘irligi
0.34 kg (0.75 lb.)
Ishlash harorati
-30 degC dan +65 degC gacha (-22 degF dan +150 degF gacha)
Saqlash harorati
-40 degC dan +85 degC gacha (-40 degF dan +185 degF gacha)
Namlik
95%, kondensatsiyasiz
O‘rnatish bo‘yicha ko‘rsatmalar
Quvvat kirish moduli stendning chap tomonida tegishli quvvat ta’minoti modulining bevosita orqasida joylashadigan, balandligi yarim o‘lchamli maxsus moduldir. Qurilmani stendning maxsus orqa uyasiga o‘rnating. Quvvatni ulashdan oldin saqlagich to‘g‘ri o‘rnatilganini (almashtiriladigan saqlagich detali raqami 01720025) tekshiring. Ishlash uchun stendga minimal yuklama talab qilinmaydi.
Muvofiqlik va sertifikatlar
EMC standartlari: EN 61000-6-2, EN 55011/CISPR 11, EN 61000-6-4
Yevropa hamjamiyati direktivalari: EMC Directive 2004/108/EC
Elektr xavfsizligi standartlari: EN 61010-1, Low Voltage Directive 2006/95/EC
Xavfli hududlar uchun tasdiqlar (Shimoliy Amerika varianti 01):
Ichki to‘siqlar bilan: Ex nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2/0, Groups A, B, C, D; T4 @ Ta = -20 degC dan +65 degC gacha
Ichki to‘siqlarsiz: Ex nC [L] IIC: Class I, Div 2; AEx nC IIC: Class 1, Div 2, Groups A, B, C, D; T4 @ Ta = -20 degC dan +65 degC gacha
Xavfli hududlar uchun tasdiqlar (ATEX varianti 02):
Ichki to‘siqlar bilan: II 3/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC dan +65 degC gacha
Ichki to‘siqlarsiz: II 3/(3) G, Ex nC[nL Gc] IIC T4 Gc, T4 @ Ta = -20 degC dan +65 degC gacha
Braziliya tasdig‘i (02-variant): BR-Ex nC [nL] IIC T4, T4 @ Ta = -20 degC dan +65 degC gacha
FAQ
Modul 3500 rack korpusi ichida jismonan qayerga o‘rnatiladi?
Modul tegishli 129486-01 quvvat ta’minoti modulining bevosita orqasidagi maxsus yarim balandlikdagi orqa uyaga o‘rnatiladi.
Elektr kuchlanishi me’yoridan oshib ketganda qurilmada nima sodir bo‘ladi?
Kirish kuchlanishining haddan tashqari oshishi ichki kirish saqlagichining uzilishiga olib keladi va quvvat taqsimlash sxemasining shikastlanishining oldini oladi.
Quvvat chiqishini barqaror saqlash uchun tizimga minimal elektr yuklamasi kerakmi?
Modul shassida to‘g‘ri ishlashi uchun minimal rack yuklamasi talab qilinmaydi.
KEPServerEX OPC UA ulanishlarini amaliy ishga tushirish ketma-ketligi: ma’lumotlar egaligini aniqlash, teglarni mahalliy ravishda sinab ko‘rish, endpoint va sertifikat ishonchliligini sozlash,...
Ethernet orqali ulangan PLCni ishga tushirish ko‘pincha kontrollerdan emas, noutbukdan boshlanadi. Mavjud sozlamalarni qayd etish, vaqtinchalik manzil tanlash, ulanishni sinab ko‘rish va ishlab...
Yonuvchan changni nazorat qilish uchun signalizatsiyaning o‘zi yetarli emas. Chang hosil bo‘lishini xaritalash, asbob-uskunalarni tanlash, blokirovkalarni loyihalash, ishlamay qolgan qayta aloqa...
Shpilka o‘ramlari paz to‘ldirish koeffitsiyentini oshiradi va ixcham tortish motorlarini yaratishga yordam beradi, biroq o‘tkazgich geometriyasi, o‘zgaruvchan tokdagi yo‘qotishlar, izolyatsiyaning...
VPN sanoat tarmog‘iga olib boradigan yo‘lni shifrlaydi, ammo PLC’lar bilan xavfsiz masofadan ishlash uchun identifikatsiyani boshqarish, segmentlarga ajratilgan kirish, o‘zgarishlarni tasdiqlash,...