| Ishlab chiqaruvchi |
Bently Nevada (Baker Hughes) |
| Model / detal raqami |
330881-28-05-070-00-02 |
| Tizim turi |
PROXPAC XL yaqinlik o‘zgartirgichi (metrik) |
| Yaqinlik datchigi kirishi |
1 metr uzunlikdagi kabelga ega 3300 XL 8 mm yaqinlik zondi |
| Quvvat talablari |
-17,5 VDC dan -26 VDC gacha, to‘siqlarsiz maksimal 12 mA iste’mol bilan; to‘siqlar bilan -23 VDC dan -26 VDC gacha |
| Chiqish qarshiligi |
50 Ohm |
| Ta’minot kuchlanishiga sezgirlik |
Kirish kuchlanishi 1 voltga o‘zgarganda chiqish kuchlanishining o‘zgarishi 2 mV dan kam |
| Zondning nominal doimiy tok qarshiligi |
7.59 Ohm ± 0.50 Ohm |
| Chiziqli diapazon |
2 mm (80 mil), nishondan 0.25 mm (10 mil) masofadan boshlab 2.3 mm gacha (10 mildan 90 milgacha) |
| Tavsiya etilgan tirqish sozlamasi |
1.27 mm (50 mil) |
| Inkremental shkala koeffitsiyenti (ISF) |
80 mil chiziqli diapazon bo‘ylab 7.87 V/mm (200 mV/mil) ± 5% (0 degC dan +45 degC gacha) |
| Eng yaxshi mos to‘g‘ri chiziqdan og‘ish (DSL) |
0 degC dan +45 degC gacha bo‘lgan komponentlarda ±0.025 mm (±1 mil) dan kam |
| Chastota javobi |
0 dan 10 kHz gacha: +0, -3 dB (305 metrgacha bo‘lgan dala simlari bilan) |
| Korpus materiali |
Ultrabinafsha (UV) nurlarga chidamli, shisha tolasi bilan mustahkamlangan, o‘tkazuvchi tolalarni o‘z ichiga olgan polifenilen sulfid (PPS) termoplastigi |
| Zond uchi materiali |
Polifenilen sulfid (PPS) |
| Zond korpusi materiali |
AISI 304 zanglamaydigan po‘lat |
| Zond kabeli |
1 metr uzunlikdagi, 75 Ohm li, ftor-etilen-propilen (FEP) izolyatsiyali triaxial kabel |
| Zond ulagichi |
Oltin qoplamali jez ClickLoc ulagichi |
| Zondning cho‘zilishdagi mustahkamligi |
Zond kabeli va korpus o‘rtasida maksimal 330 N (75 lb) |
| G‘ilof materiali va mahkamlash zanjiri |
AISI 304 zanglamaydigan po‘lat |
| G‘ilof O-ring materiali |
Neoprene |
| Ishlash harorati (zond) |
-52 degC dan +177 degC gacha (-62 degF dan +351 degF gacha) |
| Ishlash harorati (korpus/sensor) |
-52 degC dan +100 degC gacha (-62 degF dan +212 degF gacha) |
| Saqlash harorati diapazoni |
-52 degC dan +105 degC gacha (-62 degF dan +221 degF gacha) |
| Nisbiy namlik |
Ulagichlar himoyalanganida 100% kondensatsiyalanuvchi, suv ostida ishlatilmaydi |
| Korpusning tashqi ta’sirlardan himoyasi |
IP66 va NEMA Type 4X |
| Mahkamlash gaykasining tavsiya etilgan tortish momenti |
29.5 N-m (260 in-lb) |
| Zond g‘ilofi kontrgaykasining tavsiya etilgan tortish momenti |
39.3 N-m (350 in-lb) |