AS-Interface tarmoqlarini taxminsiz ishga tushirish
Ishonchli aktuator-sensor tarmoqlari uchun topologiya, quvvat va kuchlanish pasayishini tekshirish, adreslash, PLC xaritalash, nosozlik sinovlari hamda texnik xizmat ko‘rsatish qaydlarini qamrab...
Manufacturer: Bently Nevada
Product No.: 990-05-70-02-00
Country of origin:United States
Product Type: Tebranish uzatgichi
Barcode: 8537101190
Payment: T/T, Western Union
Weight: 820g
Dimensions: 7.4 sm x 4.6 sm x 10 sm
Shipping port: Xiamen
Warranty: 12 months
Bently Nevada 990-05-70-02-00 — yaqinlik zondlaridan keladigan signallarni sanoat standartidagi proporsional 4 dan 20 mA gacha bo‘lgan tok halqasi signaliga qayta ishlash uchun mo‘ljallangan, ikki simli, halqa orqali quvvatlanadigan 990 vibratsiya transmitteri. Qurilma tebranish amplitudasining cho‘qqidan cho‘qqigacha bo‘lgan qiymatini kuzatish uchun 3300 NSv yaqinlik zondi va unga mos uzaytirish kabeliga bevosita ulanadi. Ushbu transmitter mahalliy boshqaruv darajasida himoya, signalizatsiya va mantiqiy funksiyalar talab qilinadigan mashinalarni boshqarish tizimlari uchun maxsus ishlab chiqilgan yechimni taqdim etadi. U ixcham sanoat uskunalari uchun signalni qayta ishlashni optimallashtiruvchi integratsiyalangan Proximitor sensori sifatida ishlaydi.
| Suffiks kodi | Variant turi | Maydon tavsifi |
|---|---|---|
| 990 | Asosiy model | 990 vibratsiya transmitteri |
| -05 | A: To‘liq shkala varianti | 0–5 mil pp (0–125 mkm pp) |
| -70 | B: Tizim uzunligi varianti | 7,0 metr (23,0 fut) |
| -02 | C: O‘rnatish varianti | Shkottor vintlari |
| -00 | D: Agentlik tasdig‘i varianti | Talab etilmaydi |
| Kategoriya | Parametr | Spetsifikatsiya |
|---|---|---|
| Identifikatsiya | Ishlab chiqaruvchi | Bently Nevada |
| Model | 990-05-70-02-00 | |
| Elektr | Kirish | 1 ta kontaktsiz 3300 NSv yaqinlik zondi va uzaytirish kabeli |
| Quvvat talablari | Transmitter terminalidagi +12 dan +35 V gacha bo‘lgan doimiy tok kirishi | |
| Signal chiqishi | Belgilangan to‘liq shkala diapazonida 4–20 mAdc (2 simli konfiguratsiya) | |
| 4–20 mA kontur aniqligi | 250 Om qarshilik bo‘ylab belgilangan to‘liq shkala diapazonida ±1,5% ichida | |
| Maksimal kontur qarshiligi | 35 V doimiy tokda kabel bilan birga 1 000 Om | |
| Tokni cheklash | Odatda 23 mA | |
| Nol va diapazon | O‘zaro ta’sir qilmaydigan tashqi sozlamalar | |
| NOT OK/Signalni o‘chirish | Nosozlik yuz berganidan keyin 100 µs ichida signal chiqishi < 3,6 mA; 2–3 soniyada tiklanadi | |
| Quvvat yoqilgandagi bloklash | Quvvat berilgandan keyin 2–3 soniya davomida signal chiqishi < 3,6 mA | |
| Dinamik ko‘rsatkichlar | Prox Out chiziqli diapazoni | 1,4 mm (55 mil), nishondan taxminan 0,25 mm (10 mil) masofada boshlanadi |
| Prox Out shkalalash koeffitsiyenti | Odatda 7,87 mV/µm (200 mV/mil) ±6,5% | |
| Harorat barqarorligi | 0 °C dan +70 °C gacha shkalalash koeffitsiyenti 7,87 mV/µm qiymatidan ±10% doirasida qoladi | |
| Chastota javobi | 5 Hz dan 6 000 Hz gacha +0, -3 dB | |
| Nishonning minimal o‘lchami | Diametri 9,5 mm (0,375 dyuym) | |
| Atrof-muhit sharoitlari | Transmitterning ishlash harorati | -35 °C dan +85 °C gacha (-31 °F dan +185 °F gacha) |
| Transmitterni saqlash harorati | -52 °C dan +100 °C gacha (-62 °F dan +212 °F gacha) | |
| Zondning ishlash/saqlash harorati | -52 °C dan +177 °C gacha (-62 °F dan +351 °F gacha) | |
| Nisbiy namlik | 100% kondensatsiyalanuvchi, suvga botirilmagan (koaksial ulagich himoyasi bilan) | |
| Mexanik xususiyatlar | Transduser uchi materiali | Polifenilen sulfid (PPS) |
| Transduser korpusi materiali | AISI 303 yoki 304 zanglamaydigan po‘lat (SST) | |
| Zond kabelining turi | 75 Om li koaksial, ftor-etilen-propilen (FEP) izolyatsiyali | |
| Transmitter og‘irligi | 0,43 kg (0,9 lbm) | |
| Tizimning umumiy og‘irligi | Odatda 0,82 kg (1,8 lbm) |
| Interfeys / terminal | Funksiya |
|---|---|
| Transmitter terminallari | +12 dan +35 V gacha doimiy tok kontur quvvati kirishi va 4–20 mA signal chiqishi |
| PROX OUT terminali | Mahalliy diagnostika ulanishlari uchun izolyatsiyalanmagan dinamik transduser signali |
| COM terminali | Signalni tekshirish uchun umumiy tayanch nuqta |
| Koaksial ulagich | Dinamik tebranish va oraliq kuchlanishini kuzatish uchun BNC ulanishi (maks. 3 m masofa) |
| Sinov kiritish pini | Funksiya generatori orqali kontur javobini tekshirish uchun signal kiritish nuqtasi |
Proksimiti zondi nishon yuzasidan 0,5–1,75 mm (20–55 mil) masofada bo‘lishi kerak. Bu mashina ishlayotgan paytda nishon transmitterning chiziqli o‘lchash diapazonida qolishini ta’minlaydi.
O‘rnatish vaqtida komponentlar qotib qolishining oldini olish uchun rezbaning maksimal kirish uzunliklaridan oshmang. 1/4-28 rezbalar uchun chegara 0,375 dyuym, M8x1 rezbalar uchun esa 12 mm. Bently Nevada ortiqcha rezba kirishi tufayli shikastlangan zondlarni kafolat asosida almashtirishni qoplamaydi.
Qurilma 100% gacha kondensatsiyalanuvchi namlik sharoitlariga mos, germetik to‘ldirilgan konstruksiyadan foydalanadi. Kontur yaxlitligini saqlash uchun barcha koaksial ulagichlar tegishli zichlagich g‘iloflar yoki korpuslar yordamida namlikning bevosita kirishidan himoyalanishi kerak.
PROX OUT koaksial ulagichi 4–20 mA kontur zanjiridan izolyatsiyalanmagan. U yerga ulanmagan ko‘chma sinov uskunalari bilan mos keladi, biroq osiloskoplar kabi yerga ulangan, o‘zgaruvchan tokda ishlaydigan sinov uskunalariga ulashda konturlarni izolyatsiya qilish va xavfsizlik yaxlitligini saqlash uchun 122115-01 yoki 990/991 Test Adapter adapteridan foydalanishingiz kerak.
Vibratsiya transmitterlari standart mexanizmlarni himoyalash monitorlariga nisbatan qanday cheklovlarga ega?
Transmitterlar faqat cho‘qqidan cho‘qqigacha trend ma’lumotlarini taqdim etadi va signalizatsiya hodisasi paytida dinamik to‘lqin shakllarini qayd eta olmaydi. Ular fazani kuzatish, tirqish signalizatsiyasi, Timed OK kanalini bloklash, Danger Bypass yoki Trip Multiply funksiyalarini qo‘llab-quvvatlamaydi hamda System 1 kabi zavod miqyosidagi diagnostika platformalariga ulanmaydi.
Not OK sxemasi bo‘shashgan sensor ulanishlarini qanday boshqaradi?
Agar zond ulanishi bo‘shasa yoki uzilsa, transmitter 100 mikrosekund ichida kontur chiqish tokini 3,6 mA dan pastga tushiradi. Ulanish mahkamlangach, transmitter standart chiqish signalini tiklashdan oldin 2–3 soniya kutadi.
Transmitter o‘zining aniqlik spetsifikatsiyasiga javob berishi uchun qanday o‘lchamdagi nishon talab qilinadi?
Kalibrlangan shkala koeffitsiyentini saqlash uchun nishonning minimal diametri 9,5 mm (0,375 dyuym) bo‘lishi va AISI 4140 po‘latidan tayyorlangan bo‘lishi kerak.
Global Express Shipping
Returns & Warranty



Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
Greyish White
|
| Country of origin |
United States
|