1 of 1

Delta Electronics DOP-B07S411 DOP-B Series Touch Panel HMI

Delta Electronics DOP-B07S411 DOP-B Series Touch Panel HMI

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: DOP-B07S411

  • Country of origin:United States

  • Product Type: Touch Panel HMIs

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 245 mm x 195 mm x 85 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Facilitating seamless machine-to-operator interaction, the Delta Electronics DOP-B07S411 serves as a robust 7-inch widescreen operator panel engineered for harsh industrial environments. Operating on a high-speed 32-bit RISC processor, this terminal provides highly responsive touch execution and vivid graphical rendering of machine statuses. The onboard storage accommodates complex runtime projects, historical event logging, and extensive recipe storage, making it a reliable terminal for decentralized control systems.

Key Features

  • High-Resolution Display: Widescreen 7-inch TFT LCD with 800 x 480 resolution supporting up to 65,536 colors.
  • Flexible Connectivity: Three physical COM ports configured to support RS-232, RS-422, and RS-485 topologies simultaneously.
  • Expansion Options: Built-in SD card slot and USB Host port for quick project transfers, recipe management, and external peripheral interfaces.
  • Robust Front Panel: IP65/NEMA 4 rating ensures total protection against dust and low-pressure water jets.
  • Flexible Orientation: Native support for both landscape (horizontal) and portrait (vertical) mounting configurations.

Applications

  • Machine tool sequencing and CNC status monitoring.
  • Packaging machinery and automated pick-and-place lines.
  • HVAC ventilation systems and municipal pumping stations.
  • Integrated PLC networks within assembly line configurations.

Technical Specifications

Parameter Specification
Manufacturer Delta Electronics
Model Number DOP-B07S411
Series DOP-B Series
Display Size 7 inches (Diagonal)
Display Type TFT LCD (65,536 colors)
Resolution 800 x 480 pixels
Processor Type 32-bit RISC Microcontroller
Flash ROM 128 MB
Operating Voltage 24 VDC (allowable range: 24 VDC -15% to +10%)
Power Consumption 5.0 Watts Max
COM Ports COM1 (RS-232), COM2 (RS-232/RS-485), COM3 (RS-422/RS-485)
USB Interfaces 1 USB Client Ver 2.0 (data download); 1 USB Host Ver 1.1 (peripherals)
Expansion Slot SD Card (supports SDHC)
Operating Temperature 0 to 50 degC
Front Panel Protection IP65 / NEMA 4 waterproof and dustproof
Country of Origin Taiwan
Net Weight 1.0 kg
Shipping Weight (Calculated) 1.5 kg (Standard boxed weight)
Package Dimensions (Calculated) 245 mm x 195 mm x 85 mm

Connections and Interfaces

Connector / Interface Signal / Circuit Pin Assignment
COM1 (9-Pin D-Sub Male) Pin 2: RXD, Pin 3: TXD, Pin 5: GND (RS-232 Configuration)
COM2 (9-Pin D-Sub Male) Pin 1: D+, Pin 6: D- (RS-485 Differential Pair) / RS-232 shared lines
COM3 (9-Pin D-Sub Male) Pin 4: RXD+, Pin 9: RXD-, Pin 8: TXD+, Pin 3: TXD- (RS-422 Configuration)
24V DC Input Terminal Pin 1: +24V, Pin 2: 0V, Pin 3: FG (Frame Ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The DOP-B07S411 is a legacy operator panel. For modern system deployments or standard physical drop-in replacements, system designers should evaluate the newer DOP-107BV or DOP-107CV units. While the cutout dimensions are matching, the configuration must be upgraded from DOPSoft v2.xx to DOPSoft v4.00 series. Comms configurations convert smoothly, but script macros must be fully re-validated post-conversion.

Application Pitfalls & Engineering Notes

When driving heavy operations, ensure that the current draw from the USB Host port does not exceed 500mA. Attempting to power heavy external hard drives directly from the port can cause the HMI controller board to reset under low-voltage fault conditions. In highly dynamic thermal environments, maintaining continuous operating temperatures near 50 degC will degrade the fluorescent backlighting tube lifespan rapidly; configure the integrated backlight saver auto-timeout parameter within DOPSoft to mitigate local heat build-up.

Commissioning & Wiring Tips

To avoid operational communication faults, isolate the HMI's 24V DC feed using a dedicated switch-mode power supply separate from inductive loads like solenoids or contactors. Ensure that the FG terminal is connected directly to a clean instrumentation ground. Standard industrial RS-485 drops exceeding 50 meters must feature a 120-ohm termination resistor placed across the D+ and D- lines at both ends of the segment.

Installation Guidelines

CRITICAL WARNING:

De-energize all primary and auxiliary power lines before physically installing or removing this unit. Do not live-insert communication interfaces or wiring terminal blocks. Doing so risks electrostatic discharge or sudden electrical potential offsets that can destroy the driver ICs on the COM boards.

1
Prepare a mounting cutout exactly matching 196.8 mm x 142.9 mm on the panel door, ensuring a minimum clearance of 50 mm surrounding the cooling vents.
2
Seat the waterproof seal gasket uniformly in the rear bezel channel before sliding the terminal housing into the panel opening.
3
Install all supplied mounting brackets into their slot tracks on the panel frame and hand-tighten the tensioning screws evenly. Torque to 0.5 N-m to prevent casing damage.
4
Connect the dedicated 24V DC wiring harness and secure the COM port backshells to suppress cable-strain induced electrical disconnects.

How is a legacy DOP-B07S411 program migrated to modern DOP-100 Series panels?

Open your original project in DOPSoft v2.xx to ensure compilation integrity. Then, open DOPSoft v4.00, select the convert option, and choose the target DOP-100 series model. Verify and adjust communication parameters, script syntax, and register alignments.

Can I use COM2 and COM3 protocols simultaneously on this terminal?

Yes, COM2 and COM3 occupy distinct physical signal lines inside the HMI's main board, allowing independent serial protocol configurations such as MODBUS RTU and host PLC links.

What is the recommended power cable sizing and shielding requirement?

Use copper conductors rated for 22 to 16 AWG. Ensure a shielded, twisted pair is utilized for serial communication lines, grounding the cable shield strictly at one end to avoid ground loops.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...