1 of 3

IC693PWR331 GE Fanuc Series 90-30 High Capacity Power Supply

IC693PWR331 GE Fanuc Series 90-30 High Capacity Power Supply

Only 10 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC693PWR331

  • Country of origin:United States

  • Product Type: Power Supply

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 950g

  • Dimensions: 127 x 140 x 76 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The IC693PWR331 is a 30-watt, wide-range DC input High Capacity power supply specifically designed for the GE Fanuc Series 90-30 PLC. It operates on a 24 VDC nominal input and is engineered for applications requiring higher +5 VDC current capacity than standard supplies, allowing the full 30-watt output to be consumed by the +5 VDC rail. This module is a "High Capacity" version, meaning it provides robust power distribution for demanding processor and I/O configurations within a single rack.

Technical Configuration

The IC693PWR331 features a flexible hardware architecture to support various Series 90-30 system requirements:

  • Input Voltage Range: Accepts 12 to 30 VDC for continuous operation. Minimum startup voltage is 18 VDC.
  • Triple Output Logic: Provides +5 VDC for backplane logic, +24 VDC relay power, and isolated +24 VDC output for external circuits.
  • Serial Communication: Includes integrated RS-485 compatible serial port for programmer or operator interface connection.
  • System Diagnostics: Four LED indicators: PWR, OK, RUN, and BATT for power and system status monitoring.
  • Battery Support: Provides connector for lithium backup battery to maintain CMOS memory and real-time clock.

Technical Specifications

Feature Details
Model IC693PWR331
Nominal Rated Voltage 24 VDC
Input Voltage Range Run: 12 to 30 VDC
Start: 18 to 30 VDC
Maximum Input Power 50 W at full load
Total Output Power 30 W maximum combined output
+5 VDC Output 5.0 to 5.2 VDC, 30 W maximum
+24 VDC Isolated Output 19.2 to 28.8 VDC, 20 W maximum
+24 VDC Relay Output 19.2 to 28.8 VDC, 15 W maximum
Holdup Time 10 ms minimum
Operating Temperature Derating required above 50 deg C

Technical FAQs

Can I use the full 30 watts just for the PLC rack modules?
Yes. For applications requiring significant +5 V current, the supply allows the full 30 W to be drawn from the +5 VDC output if other rails are lightly loaded.

What happens if the isolated 24 VDC output is shorted?
If the isolated +24 VDC output is overloaded or shorted, the controller stops operation to protect the system.

Why will the power supply not start at 15 VDC?
The unit can operate down to 12 VDC after startup, but requires at least 18 VDC during initial power-up.


Engineering & Installation Guide

  • Field Wiring Input: Connect DC input to the top three terminals. Top terminal is positive, second terminal is negative, third terminal is ground.
  • External Power Output: Bottom terminals provide isolated +24 VDC output. Total load must remain within the 30 W limit.
  • Thermal Management: Above 50 deg C ambient temperature, reduce +5 VDC output load to maintain stable operation.
  • Input Power Calculation: Multiply total output power by 1.5, then divide by input voltage. Add 10 to 20 percent margin.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered Battery-powered

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...