1 of 1

Omron S8VK-WA24024 S8VK-W Series Three-phase Input Power Supply

Omron S8VK-WA24024 S8VK-W Series Three-phase Input Power Supply

Only 6 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: S8VK-WA24024

  • Country of origin:Japan

  • Product Type: Three-phase Power Supplies

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Operating as a high-efficiency electrical conversion module, the Omron S8VK-WA24024 delivers stable direct current to demanding industrial automation networks from a three-phase power source. This switch-mode power supply is engineered to mitigate phase unbalance risks and provide continuous, reliable 24 VDC output within compact control cabinets. Designed with a robust covered housing and integrating Omron's proprietary Push-In Plus terminal connection technology, the unit minimizes installation labor while maximizing resistance to physical vibrations common in heavy industrial manufacturing environments.

Features

  • Three-Phase Input: Supports input ranges from 200 to 240 VAC, reducing neutral current loading and balancing phases.
  • Push-In Plus Terminals: Enables rapid, tool-free wiring that maintains continuous tension to prevent terminal loosening under vibration.
  • Dynamic Current Boost: Delivers up to 15 A of maximum boost current to support high-inrush startup loads such as solenoids, motors, and capacitive circuits.
  • Space-Saving Footprint: Highly compact side-by-side mounting design optimizes DIN-rail space allocation.
  • IP20 Protection: Covered construction provides finger-safe operation and compliance with EN/IEC 60529 standards.

Applications

  • Automotive assembly machinery control panels
  • High-speed packaging and sorting systems
  • Semiconductor fabrication tool power distribution
  • Water and wastewater treatment processing equipment
  • General manufacturing plant PLC and sensor power networks

Technical Specifications

Specification Parameter Verified Engineering Value
Manufacturer Omron
Model Number S8VK-WA24024
Series Name S8VK-W
Rated Input Voltage 200 to 240 VAC (Three-Phase)
Power Rating 240 W
Rated Output Voltage 24 VDC
Rated Output Current 10 A
Maximum Boost Current 15 A
Terminal Type Push-In Plus Terminal Block
Construction Type Covered
Degree of Protection IP20 (EN/IEC 60529)
Unit Weight 0.8 kg
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Terminal Block Section Terminal Designation Functional Assignment
Input Terminals (Top) L1 AC Input Phase 1
L2 AC Input Phase 2
L3 AC Input Phase 3
PE (Ground Symbol) Protective Earth Ground (Safety Ground)
Output Terminals (Bottom) +V (1) Positive 24 VDC Output Line 1
+V (2) Positive 24 VDC Output Line 2
-V (1) Negative 24 VDC Output Line 1 (Return)
-V (2) Negative 24 VDC Output Line 2 (Return)

Empirical Engineering Insights

Alternative Models & Compatibility

The S8VK-WA24024 serves as a more reliable alternative to single-phase S8VK-G or S8VK-X units when deployed in facilities suffering from persistent neutral line noise or phase unbalance. Because it derives power across three balanced phases, it prevents the local neutral circuit from overheating. When substituting this unit for older legacy switch-mode models, verify the 3-phase line configuration, as this module requires a nominal input of 200 to 240 VAC to meet the rated 240W threshold.

Application Pitfalls & Engineering Notes

A common mistake during panel integration is overloading the 15 A boost current duration. While the S8VK-WA24024 cleanly handles up to 150% of its rated capacity, this boost is strictly rated for temporary duty cycles. Continuous operation beyond the designated peak window will trigger thermal overcurrent protection, causing the output voltage to dip or cycle. Ensure the control cabinet maintains at least 15 mm of free spacing on both side panels and 50 mm vertically to allow optimal convection cooling, as restricted air passage accelerates thermal degradation.

Commissioning & Wiring Tips

To ensure gas-tight connections with the Push-In Plus mechanism, strip solid conductor wires or crimped ferrules to exactly 10 mm. When introducing stranded wires without ferrules, utilize a flathead precision screwdriver to depress the orange release tab prior to inserting the wire. Avoid twisting the stranded wires to prevent individual copper strands from splaying, which can lower the effective contact cross-section and generate localized hotspot resistance.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and secondary electrical systems before attempting installation, wiring, or physical inspection of the S8VK-WA24024. Confirm that the input line voltage matches the rated three-phase range (200 to 240 VAC) to prevent immediate terminal and internal capacitor damage.
1
Mount the power supply unit securely onto a standard 35mm DIN rail. Ensure the lock lever on the back of the chassis snaps firmly into place.
2
Wire the Protective Earth (PE) terminal first to a certified panel ground bus to establish appropriate EMI suppression and fault safety pathing.
3
Insert the three incoming phase wires (L1, L2, L3) into the top terminal block blocks, verifying that each wire is locked securely into position.
4
Connect the 24 VDC system load lines to the corresponding +V and -V output terminals located on the bottom block. Double-check polarity alignment before applying line voltage.

What are the benefits of using a three-phase power supply like the S8VK-WA24024 over a single-phase model?

Using three-phase AC input eliminates neutral conductor currents, reduces input line current per phase, and significantly improves system reliability under load unbalance across the main facility distribution lines.

How long can the S8VK-WA24024 sustain its peak boost current of 15 A?

The maximum 15 A boost current is designed for transient startup loads and should only be sustained for a short duration, typically up to 5 seconds. Exceeding this limit triggers internal thermal protection mechanisms.

Are tools required to connect cables to the Push-In Plus terminal blocks?

No. Solid wires and stranded wires with crimped ferrules can be inserted directly without tools. Uncrimped stranded wires require depressing the integrated release tab with a small flathead screwdriver during insertion.

What are the minimum clearances required around the power supply inside the enclosure?

For natural air convection cooling, maintain a minimum clearance of 15 mm on both horizontal sides of the unit and 50 mm above and below the housing.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Suyuqlik quvvat tizimlarini almashtirish uchun mo‘ljallangan elektr aktuatorlar: Amaliy sanoat avtomatizatsiyasi qo‘llanmasi

Ushbu maqola SMCning e-Actuator seriyasi kabi integratsiyalashgan elektr aktuatorlarining sanoat harakatini boshqarishda an’anaviy pnevmatik va gidravlik tizimlarni qanday almashtirayotganini...

Sanoat avtomatlashtirish ilovalari uchun OpenPLC yordamida matematik amallar bajarish

Ushbu maqola PLC tizimlari sanoat avtomatlashtirishida qo‘shish, ayirish, ko‘paytirish, bo‘lish, modulo va darajaga ko‘tarish kabi asosiy matematik amallarni qanday bajarishini tushuntiradi. Unda...

FBD PLC dasturlashda ilg‘or Boolean mantiqi: asosiy mantiqdan tashqari amaliy sanoat ilovalari

Maqola PLC dasturlashda asosiy AND, OR va NOT amallaridan tashqari bir nechta ilg‘or Boolean mantiq funksiyalarini tushuntiradi. Unda haqiqat jadvallari, multiplexerlar, impuls generatorlari va...

PLC dasturlashda Boolean mantiqi: FBD mantiq eshiklarini tushunish

Boolean mantiq har bir PLC dasturining asosidir. Oddiy mashina boshqaruvlaridan tortib murakkab sanoat avtomatlashtirish tizmlarigacha, mantiqiy eshiklar boshqaruvchilarning o‘zgaruvchan kirishlar va...