Description
The Siemens 6AV7612-0AF10-0BH0 SIMATIC Panel PC 670 is an industrial panel PC featuring a 12" TFT Touch Display. This standard configuration unit is equipped with a Celeron 300 MHz CPU, 64 MB RAM, a 40 GB Hard Drive, and a CD-ROM drive. Designed for industrial environments, it operates on a 115-230 V power supply and comes pre-installed with Windows NT 4.0 (German version), making it suitable for various human-machine interface (HMI) and control applications within automation systems.
Features
- 12" TFT Touch Display
- Celeron 300 MHz CPU
- 64 MB System RAM
- 40 GB Hard Disk Drive (HD)
- Integrated CD-ROM Drive
- Input Voltage: 115-230 V AC
- Pre-installed Windows NT 4.0 (German)
Applications
The SIMATIC Panel PC 670 is typically deployed in industrial settings requiring a robust and integrated HMI solution. Common applications include:
- Machine operation and control
- Process visualization and monitoring
- Data acquisition and logging
- Production line management
- Building automation systems
Technical Specifications
| Manufacturer |
Siemens |
| Range |
Simatic Panel PC |
| Subrange |
PC670 |
| Product Type |
PC panels |
| Display Type |
12" TFT Touch Display |
| CPU |
Celeron 300 MHz |
| RAM |
64 MB |
| Hard Drive |
40 GB |
| Optical Drive |
CD-ROM |
| Operating System |
Windows NT 4.0 (German) |
| Input Voltage |
115-230 V AC |
| Product Phase |
Obsolete |
| Logistics Weight |
4.00 kg |
| Commodity Code |
85371091 |
| Export Control Regulations (ECCN) |
N |
| Package Dimensions (Calculated) |
Not specified |
Installation Guidelines
Proper installation ensures reliable operation and longevity of the SIMATIC Panel PC 670. Adhere to the following general guidelines:
-
Power De-energization: Always ensure that all power to the installation site is de-energized before beginning any work on the panel PC or its connections.
-
O‘rnatish: Panel PC’ni mos boshqaruv shkaf
-
Yerga ulash: Elektr xavflarining oldini olish va EMC talablariga muvofiqlikni ta’minlash uchun panel PC korpusiga mustahkam himoya yer (PE) ulanishini o‘rnating.
-
Elektr ta’minotiga ulash: 115-230 V AC tarmoq kabelini barqaror quvvat manbaiga ulang. Yoqishdan oldin kuchlanish va chastotaning to‘g‘riligini tekshiring.
-
Periferik ulanishlar: Zarur periferik qurilmalarni (masalan, klaviatura, sichqoncha va tarmoq kabellari) tegishli portlarga ulang. Kabellarni zo‘riqish va xalaqitni kamaytiradigan tarzda yo‘naltiring.
-
Atrof-muhit sharoitlari: Qurilmani ish barqarorligini ta’minlash uchun haddan tashqari chang, namlik, korroziv gazlar va keskin harorat o‘zgarishlari bo‘lmagan muhitga o‘rnating.
-
Ventilyatsiya: Issiqlikni to‘g‘ri chiqarish uchun sovitish teshiklari to‘sib qo‘yilmaganiga ishonch hosil qiling.
-
Yoqish: Barcha ulanishlar mustahkam va to‘g‘ri ekanligi tekshirilgach, elektr ta’minotini qayta yoqing. Tizimning to‘g‘ri yuklanishi va ishlashini kuzating.