1794-IE8 Allen-Bradley FLEX I/O 8-Channel Analog Input Module

1794-IE8 Allen-Bradley FLEX I/O 8-Channel Analog Input Module

Only 3 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: 1794-IE8

  • Country of origin:Hoa Kỳ

  • Product Type: Flex 8 Point Analog Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 120g

  • Dimensions: 9.3cm x 5cm x 5.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview and Distributed I/O Efficiency

The 1794-IE8 (1794IE8) is a high-density analog input module designed for the FLEX I/O platform, one of the most successful distributed I/O systems in industrial history. Engineered for modularity and space efficiency, this module provides 8 non-isolated inputs that can be individually configured for either voltage or current signals. The 1794-IE8 is an essential component for high-point-count systems in water treatment, chemical processing, and HVAC control, where mounting I/O closer to the field sensors is required to reduce wiring costs. By utilizing a separate terminal base, the 1794-IE8 allows for "Removal and Insertion Under Power" (RIUP), ensuring that maintenance can be performed without shutting down the entire control network.

Hardware Architecture and Signal Flexibility

The 1794-IE8 interfaces with the network (EtherNet/IP, ControlNet, or DeviceNet) via a FLEX I/O adapter. Its design separates the electronic module from the field wiring, providing a clean and serviceable installation.

  • Configurable Input Ranges: Supports standard industrial signals including 4 to 20 mA and 0 to 20 mA for current loops, as well as +/- 10 V, 0 to 10 V, and 0 to 5 V for voltage inputs.

  • A/D Conversion: Employs a 12-bit successive approximation converter, delivering a resolution of 1.22 uA/count for current and 2.56 mV/count for voltage (at 10 V range).

  • Modular Mounting: Snaps easily onto a 1794-TB2, 1794-TB3, or 1794-TB3S terminal base, which contains the wiring points and the communication backplane.

  • Data Format: Presents data to the controller in a 16-bit 2's complement integer format, facilitating easy scaling within Logix Designer or RSLogix 5000 routines.

Technical Specifications

Specification Details
Model 1794-IE8
Manufacturer Allen-Bradley / Rockwell Automation
Number of Inputs 8 Single-ended, Non-isolated
Resolution 12-bit
Current Inputs 4 to 20 mA, 0 to 20 mA
Voltage Inputs +/- 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V
Conversion Rate 256 microseconds for all channels
Flexbus Current 20 mA @ 5 VDC
External DC Power 24 VDC Nominal (10.5 to 31.2 VDC range)
Operating Temp 0 to 55 Celsius
Shipping Weight 0.8 kg

Integrated Technical FAQ

How do I switch between voltage and current modes on the 1794-IE8?

Mode selection is handled via the module's configuration word in the controller software. There are no physical jumpers on the module itself; you simply set the bits in the output image of the I/O adapter to define the signal type for each channel.

What is the advantage of using a Terminal Base (e.g., 1794-TB3) with this module?

The terminal base allows you to wire the sensors once and leave them in place. If the 1794-IE8 electronics fail, you can pull the module off the base and snap on a new one without touching a single screwdriver, drastically reducing Mean Time to Repair (MTTR).

Does this module provide power to 2-wire transmitters?

The 1794-IE8 module itself does not provide loop power. When using 2-wire transmitters, you must use a terminal base like the 1794-TB3 which has extra terminals to distribute the 24 VDC field power to the sensors.


Engineering & Installation Protocols

  • Terminal Base Alignment: When installing the module, align the keys on the bottom of the 1794-IE8 with the slots on the 1794-TB3. Press firmly until the latching mechanism clicks. An improperly seated module can lead to intermittent "I/O Connection Faults" on the network.

  • Current Loop Protection: When configuring channels for 4 to 20 mA, ensure that the external 24 V power supply is stable. The module has a maximum input current rating of 32 mA; exceeding this can damage the internal precision resistors.

  • Shield Termination: For analog accuracy, use shielded cables and terminate the shield at the ground lugs provided on the 1794-TBC or the grounded DIN rail. Avoid grounding both ends of the shield to prevent ground loops that induce 50/60 Hz ripple into the 12-bit conversion.

Engineering Advantages

The 1794-IE8 stands out for its high-speed throughput. With a conversion rate of 256 microseconds for all 8 channels, it provides near-real-time data for fast-acting control loops. Its non-isolated design is a cost-effective choice for systems where all sensors share a common reference point, allowing for high-density analog acquisition without the bulk or expense of isolated modules. Its compatibility across all major industrial networks ensures it remains a flexible asset in both legacy PLC-5/SLC systems and modern ControlLogix architectures.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...