  • Product No.: ICSO08Y1 FPR3311101R0026

  • Country of origin:Thụy Sĩ

  • Product Type: Digital Output Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 12.2 cm x 9.5 cm x 6.3 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The ABB ICSO 08 Y1 FPR3311101R0026 serves as a remote digital output module designed for deployment on the ABB Procontic CS31 system bus topology. This hardware component contains 8 electrically isolated output channels operating with solid-state transistors to execute precise control commands within automated process networks. Engineered to distribute discrete signals safely, the module integrates automated local diagnosis functions and maintains built-in protection parameters to monitor structural channel errors and avoid operational downtime.

Features

  • Transistor-based output architecture providing reliable switching speeds across 8 independent channels.
  • Complete electrical isolation built between the CS31 system bus interface and internal output electronics to isolate control loops.
  • Integrated short-circuit and overload protection configurations per channel ensuring robust field survival.
  • Front panel diagnostic array featuring status indicators and a dedicated manual test switch for physical troubleshooting.

Applications

  • Remote output routing within standard Advant Controller 31 distributed architectures.
  • Solenoid valve actuation and localized power relay distribution networks.
  • Discrete binary signal handling in centralized manufacturing and process environments.

Ordering Information

Module / Accessory Technical Description Order Number
Plug-in base ECZ Mechanical interface base FPR3700001R0001 
Module ICSO 08 Y1 24 V DC Version FPR3311101R1022 
Module ICSO 08 Y1 230 V AC Version FPR3311101R0026 

Technical Specifications

Parameter Value
Manufacturer ABB
Product ID FPR3311101R0026
ABB Type Designation ICSO 08 Y1 230VAC
Number of Outputs 8 (electrically isolated)
Rated Supply Voltage 230 V AC, 50 or 60 Hz
Process Supply Voltage UP 24 V DC
Rated Current per Output 2 A
Total Current of 8 Outputs max. 8 A
Maximum Current Consumption 0.2 A (without output loads)
Maximum Power Consumption 6 VA (without output loads)
Maximum Power Dissipation 6 W
Output Leakage Current (Signal 0) < 4 mA
Maximum Lamp Load 15 W
Switching Frequency (Inductive Load) max. 0.1 Hz
Signal Indication 1 yellow LED per channel
Product Net Weight 0.3 kg

Connections/Interfaces

Terminal Number Terminal Label Function
1 BUS2 CS31 System Bus Connection 
2 BUS1 CS31 System Bus Connection 
3 Shield CS31 System Bus Shield 
7 ZP Reference Potential 0 V 
8...15 A0...A7 Alternative Digital Output Terminals 
16 L1 Mains Connection Line 1 (230 V AC) 
17 N Mains Connection Neutral 
18 PE Protective Earth 
19 UP Process Voltage +24 V DC (Parallel Connection 1) 
20 UP Process Voltage +24 V DC (Parallel Connection 2) 
21...28 A0...A7 Secondary Digital Output Connections 
30 ZP Reference Potential 0 V 

Installation Guidelines

  • Base Mounting: The module must be securely mounted onto the plug-in base ECZ and fastened using the two integrated panel screws.
  • Mechanical Coding: Set the mechanical coding ring on the ECZ plug-in base to match the correct supply voltage prior to plugging the module in.
  • Process Voltage Sequencing: The external process voltage supply must be switched on before or simultaneously with the 230 V AC mains supply.
  • Parallel Power Infeed: Connect the process voltage in parallel across both terminal 19 and terminal 20 to handle the aggregate output load capacity up to 8 A.
  • Minimum Loading: Ensure each active channel supports a minimum current load of at least 50 mA to prevent leakage paths from disrupting the safe OFF state.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB ICSO 08 Y1 FPR3311101R0026 Advant Controller 31 Digital Output Module

What is the minimum load requirement for the module?

The minimum load must be greater than or equal to 50 mA per channel to guarantee a safe OFF state due to minor transistor leakage currents.

How are module faults and field channel errors verified locally?

Errors are diagnosed using the onboard test button alongside the 8 yellow front-panel LEDs which flash patterns indicating unit errors, bus errors, supply errors, overloads, or short circuits.

Can the digital outputs handle incandescent lighting loads?

Yes, the transistor outputs are rated to switch direct lamp loads up to a maximum capacity of 15 W.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Thụy Sĩ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...