1 trong số 3

Allen-Bradley 1756-OW16I ControlLogix 16 Point Digital Relay Module

Allen-Bradley 1756-OW16I ControlLogix 16 Point Digital Relay Module

Only 5 item(s) left in stock
  • Manufacturer: Allen-Bradley

  • Product No.: Allen Bradley 1756-OW16I

  • Country of origin:Hoa Kỳ

  • Product Type: Digital Relay Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 3.5cm x 14cm x 14.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Technical Overview

The 1756-OW16I operates as a high-integrity, single-slot digital contact output assembly designed for the Allen-Bradley ControlLogix architecture. Engineered specifically for complex process interlocks in thermal power plants, oil refining tank farms, and heavy mining infrastructure, this module provides sixteen independent, Form A normally open relay contact channels. Each output circuit features complete galvanic isolation from adjacent channels and backplane logic, allowing distinct AC and DC field voltages to operate simultaneously on a single module housing. By eliminating common ground reference pathways and suppressing high-voltage transient cross-talk, this module avoids cascaded channel failures, effectively reducing unexpected field instrumentation downtime in high-vibration and electrically noisy industrial processing environments.

System Architecture and Functional Features

The hardware topology of this digital relay assembly utilizes sixteen discrete, mechanically robust contact relays configured with basic insulation barriers rated for continuous 250 V electrical isolation. It provides native scheduling capabilities, enabling synchronization of contact state transitions within 16.7 ms maximum with reference to the Coordinated System Time (CST) matrix of the Logix backplane. The module features independent, software-configurable state management for both Fault Mode and Program Mode, allowing system engineers to predefine individual channel responses—Hold Last State, Forced On, or Forced Off (default)—to preserve safe field conditions during processor disruption. It requires no internal hardware jumpers, relying instead on electronic software keying via the integrated development environment to prevent erroneous module cross-insertion during field maintenance.

Engineering Specifications

Specification Metric Verified Technical Data
Model 1756-OW16I
Brand Allen-Bradley
Series ControlLogix Digital I/O
Output Type Relay Contacts (16 Form A Normally Open, Individually Isolated)
Operating Voltage Window 5 to 125 VDC / 10 to 240 VAC (50/60 Hz)
Current Draw from Backplane 150 mA @ 5.1 VDC and 150 mA @ 24 VDC
Total Backplane Power Consumption 4.4 W
Power Dissipation (Max) 4.5 W @ 60 deg C (140 deg F)
Thermal Dissipation Loading 15.35 BTU/hour
Continuous Contact Ratings (DC) 1 A @ 5-30 VDC, 0.5 A @ 48 VDC, 0.22 A @ 125 VDC
Continuous Contact Ratings (AC) 1.5 A @ 120 VAC, 0.75 A @ 240 VAC (50/60 Hz)
Pilot Duty Classifications C300, R150
Minimum Contact Load Current 10 mA
Initial Contact Resistance (Max) 100 mOhm @ 6 VDC, 1 A
Off-State Leakage Current (Max) 1.5 mA per point
Contact Switching Delays Off to On: 10 ms max / On to Off: 10 ms max
Maximum Switching Frequency 1 operation per 3 seconds (0.3 Hz at rated load)
Isolation Voltage Stability 250 V continuous (basic insulation type), outputs-to-backplane and output-to-output
Compatible Removable Terminal Blocks 1756-TBCH, 1756-TBNH, 1756-TBSH, 1756-TBS6H
Operating Temperature Range 0 to 60 deg C (32 to 140 deg F)
Shock Tolerance Operating: 30 G / Non-operating: 50 G
Vibration Resistance 2 G @ 10 to 500 Hz
North American Temp Code T4A
Weight 0.30 kg (0.66 lbs)
Dimensions Standard single-slot ControlLogix module envelope
Origin USA

FAQs

What is the significance of the 10 mA minimum load current specification on the 1756-OW16I?

The electromagnetic contacts require a minimum wetting current of 10 mA to reliably pierce thin film oxidation layers that naturally develop on the contact surfaces over time. Operating below this current threshold can result in erratic signal continuity or false open-circuit indications despite the relay coil being energized.

Does the 1756-OW16I contain internal fused protection to isolate shorted field loads?

No. The module is not internally fused. To protect the relay contact pathways from overcurrent damage due to field faults, external fusing must be applied. Utilizing a fused Interface Module (IFM) matching publication 1492-TD008 is recommended, though agency certifications are restricted to direct connections via standard ControlLogix Removable Terminal Blocks (RTBs).

Why is the maximum switching frequency limited to 0.3 Hz at rated load?

Because the 1756-OW16I relies on mechanical contacts rather than solid-state triacs or transistors, excessive cycle speeds induce thermal stresses and arc degradation. Restricting the cycle rate to 1 operation per 3 seconds prevents contact overheating and ensures the expected contact lifespan of 300 kHz for resistive loads and 100 kHz for inductive loads.


Field Commissioning and Safety Declarations

  • Arc Mitigation for Inductive Loads: When controlling inductive field elements such as motor starter coils or high-capacity solenoids, external surge suppressors must be installed directly across the load terminals. Use an appropriate RC snubber circuit for AC loops and a freewheeling diode for DC loops. Unsuppressed inductive counter-electromotive force (back-EMF) will accelerate contact degradation, resulting in contact welding and catastrophic module damage.

  • Terminal Assembly Selection and Grounding: Field conductor hookups must be handled using official 36-pin or 20-pin RTBs (e.g., 1756-TBCH, 1756-TBNH). Separate all high-voltage AC current lines from low-voltage DC logic wires by routing them through independent wire ways within the marshalling panel. Ensure the chassis frame maintains a low-impedance connection to the central plant earth ground plane.

  • Live Maintenance Warning (RIUP Restrictions): Although the underlying ControlLogix architecture allows Removal and Insertion Under Power (RIUP) during operational maintenance, executing this process in hazardous locations (Class I Division 2, Temp Code T4A) is dangerous. Field-side supply circuits must be completely isolated and checked for zero voltage before detaching the mechanical terminal blocks or pulling the module from the chassis.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ
Power source
Chạy bằng điện AC Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...