1 trong số 1

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

B&R X20CM0985 X20 System 3-Phase Energy Measurement Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20CM0985

  • Country of origin:Hoa Kỳ

  • Product Type: Analog inputs

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The X20CM0985 (X20CM0985) is a sophisticated 3-channel analog input module designed for comprehensive power and energy measurement within the B&R X20 System. This module is engineered to monitor 3-phase electrical networks, supporting direct voltage inputs of up to 480 VAC and current inputs of 1 A or 5 A AC via external transformers. In energy-intensive industries such as plastics processing, metal fabrication, and large-scale manufacturing, the X20CM0985 provides the critical data required for load management, predictive maintenance, and energy efficiency auditing. By delivering high-precision measurements of active, reactive, and apparent power directly to the PLC, it enables engineers to optimize machine performance and reduce operational overhead through real-time grid analysis.

Technical Configuration

The X20CM0985 integrates complex signal processing within the standard X20 form factor. It features three independent channels for simultaneous current and voltage measurement, allowing for the calculation of phase angles and harmonic distortion. The internal hardware is robust, consuming 1.05 W from the X20 bus and 4 W for the internal I/O circuitry. It is designed for high-voltage environments with a rated input capacity of 120 VAC to 480 VAC, making it compatible with most global industrial power grids. The module utilizes specialized A/D converters to handle the AC waveforms, ensuring that peak values and RMS calculations are performed with minimal latency. With an IP 20 protection rating, it is intended for installation in controlled electrical cabinets where space-saving and modularity are prioritized.

Technical Specifications

Feature Specification
Model X20CM0985
Brand B&R (Bernecker + Rainer)
Module Type Analog Input / Energy Measurement
Number of Channels 3 (Current and Voltage)
Voltage Input Range 120 VAC to 480 VAC
Current Input Range 1 A or 5 A AC
Bus Power Consumption 1.05 W
Internal I/O Consumption 4 W
Degree of Protection IP 20
Operating Temp 0 to 55 deg C
Dimensions 12.5 x 99 x 75 mm
Shipping Weight 2.0 kg

Technical FAQs

Can the X20CM0985 measure power in both 3-phase and single-phase systems?

Yes, the module is designed for 3-phase systems but can be configured to monitor three individual single-phase circuits. This flexibility allows for the monitoring of multiple high-load single-phase actuators within a single machine using only one module.

Does this module require external current transformers (CTs)?

Yes, for current measurement, the X20CM0985 must be interfaced with external current transformers that provide a secondary output of either 1 A or 5 A AC. Direct connection of high-current power lines to the module will result in immediate hardware failure.

What specific electrical parameters can be calculated by the X20CM0985?

Beyond standard voltage and current, the module provides data for active power (W), reactive power (var), apparent power (VA), energy consumption (Wh), and power factor (cos phi). It also supports frequency measurement and basic harmonic analysis.


Engineering & Installation Guide

  • Current Transformer Polarity: When wiring the 1 A or 5 A current inputs, strict adherence to the S1 (k) and S2 (l) polarity is essential. Reversing the polarity on a single phase will result in incorrect power factor readings and negative energy calculations for that specific phase.

  • Voltage Path Protection: Always install 3-pole circuit breakers or fuses (typically rated at 1 A to 2 A) in the voltage measurement path between the power line and the X20CM0985. This protects the module and the X20 backplane from catastrophic failure in the event of a line-to-line short circuit within the measurement loop.

  • Shielding and Grounding: Given the proximity to high-voltage lines, the X20CM0985 is susceptible to electromagnetic interference. Ensure the X20 bus module is properly snapped onto a grounded DIN rail. Use shielded cables for the current transformer secondaries and ground the shield at a single point to prevent circulating ground currents from skewing measurement accuracy.

 

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Hoa Kỳ
Power source
Chạy bằng điện AC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...