1 trong số 1

B&R X20DS438A B&R X20 IO-Link Master Module

B&R X20DS438A B&R X20 IO-Link Master Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20DS438A

  • Country of origin:Hoa Kỳ

  • Product Type: X20 IO-Link Master Module

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The X20DS438A (X20DS438A) is a high-performance IO-Link master module within the B&R X20 system, designed to integrate up to four IO-Link devices into a centralized control network. By providing seamless communication with smart sensors and actuators, this module enables advanced diagnostic capabilities and remote parameterization, significantly reducing configuration time and enhancing process transparency. Engineered for rigorous industrial environments, it features electrical isolation between the bus and the IO-Link interface, ensuring high data integrity and protection against electrical noise in complex automation cells.

Technical Configuration

The X20DS438A utilizes a 3-pin connection architecture, supporting standard unshielded sensor cables up to 20 m in length. It features a robust diagnostic suite, allowing operators to monitor module status, IO-Link operating states, and C/Q channel status via both hardware LED indicators and software-based real-time feedback.

With a B&R ID code of 0xCAC0, the module is natively recognized by Automation Studio, facilitating quick commissioning. Power management is a key strength, providing up to 12 W per IO-Link interface. The module also features user-configurable overload protection, allowing for specific switch-off delays and durations, which prevents nuisance trips while ensuring hardware safety during short-circuit events.

Technical Specifications

Feature Specification
Model X20DS438A
Brand B&R
Series X20
Module Type IO-Link Master
Interfaces 4 x IO-Link
ID Code 0xCAC0
Cable Limit Max. 20 m
Power per Channel Max. 12 W
Isolation Bus to IO-Link
Op Temp (Horizontal) -25 to 60 deg C
Weight 1 kg

FAQs

What cable specifications are required for the IO-Link interfaces?

Use 3-pin standard sensor cables. To ensure reliable communication, the cable length must not exceed 20 m, with a maximum line capacitance of 3 nF and a maximum loop resistance of 6 Ohm.

How does the overload protection function?

The module features electronic short-circuit and overload protection. The switch-off delay and duration are fully configurable via software, allowing the system to handle temporary inrush currents without shutting down the channel unnecessarily.

Can I monitor the module diagnostics remotely?

Yes. Comprehensive diagnostics for the module run/error state, IO-Link operating mode, and C/Q channel status are accessible via the B&R software environment, providing immediate alerts during abnormal process conditions.

What is the impact of mounting orientation on operating temperature?

Due to thermal convection properties, horizontal mounting allows for an operation range of -25 to 60 deg C, while vertical mounting limits this to -25 to 50 deg C.

Installation and Thermal Management

  • Thermal Considerations: Always prioritize horizontal mounting whenever the cabinet design permits to achieve the maximum operating temperature rating of 60 deg C. Ensure that the module is not obstructed by cable trunks or other components that could impede airflow.
  • Short-Circuit Protection: When configuring the overload protection, account for the startup current of your specific sensors. Setting the switch-off delay too short for high-capacitive sensors may lead to false error flags during power-up sequences.
  • Cable Routing: Although the module supports unshielded cables, maintain physical separation between IO-Link lines and high-current motor cables. Even with electrical isolation, minimizing proximity to high-frequency electromagnetic interference sources will ensure the most stable IO-Link communication.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...