Beckhoff C9900-E768 CP6xxx and CP7xxx Control Panel Push-Button Extension

Beckhoff C9900-E768 CP6xxx and CP7xxx Control Panel Push-Button Extension

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E768

  • Country of origin:Đức

  • Product Type: Push-Button Extensions

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed to expand physical operator interfaces on machine-level HMI installations, the BECKHOFF C9900-E768 provides external tactile controls mounted directly on the right side of compatible industrial displays. Built specifically for 15-inch CP6x22-00xx and CP7x22-00xx Control Panels and Panel PCs operating without integrated keyboards, this auxiliary module adds heavy-duty physical control keys while maintaining structural integration. It is an optimal hardware solution for applications transitioning through the manufacturer's active service phase, ensuring legacy systems maintain tactile controls. The integration of Siemens Signum square hardware and dual-path connection mechanisms delivers rugged and reliable performance in demanding industrial environments.

Features

  • Right-Side Interface Extension: Seamlessly mounts onto the right frame of 15-inch Beckhoff display units.
  • Industrial Key Array: Features 14 Siemens Signum square (30 x 30 mm) push-buttons equipped with integrated signal lamps.
  • Dedicated Emergency Stop: Includes 1 high-visibility Siemens Signum emergency stop button designed for direct hardware safety circuit routing.
  • Dual Contact Functionality: Supports a primary normally-open (NO) contact routed over CP-Link or USB, alongside a secondary hardwired NO contact accessible via a terminal row.
  • Customizable Marking: Clear, insertable label caps allow rapid on-site labeling of individual button functions.

Applications

  • Automotive Assembly Lines: Integrated right-side controls for manual machine overrides and system restarts.
  • Process Plant Visualization: Hardwired E-stop and control interface expansion directly adjacent to the main screen.
  • Legacy Panel Maintenance: Direct drop-in component replacement for CP6x22 and CP7x22 installations requiring ongoing service lifecycle support.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation GmbH & Co. KG
Article Number / SKU C9900-E768
Compatible Displays 15-inch CP6xxx and CP7xxx without built-in keyboard (specifically CP6x22-00xx and CP7x22-00xx)
Mounting Position Right-hand side of panel
Push-Button Type 14 x Siemens Signum square, 30 x 30 mm
Emergency Stop Type 1 x Siemens Signum, direct hardwire configuration
Key Signal Transmission USB or CP-Link (Contact 1) / Direct terminal strip (Contact 2)
Lamp Signal Transmission Exclusively via CP-Link or USB interface
Lifecycle Phase Service Phase (Legacy Support)
Shipping Weight 5.0 kg (11.0 lbs)

Connections and Interfaces

Interface Path Function and Wiring Assignment
CP-Link / USB Bus Connection Transmits digital key state of Contact 1 for all 14 push-buttons; drives power to all integrated signal lamps.
Rear Terminal Strip Provides independent, hardwired access to the isolated Contact 2 (Normally Open) of each of the 14 push-buttons.
Emergency Stop Terminals Dedicated, fully-isolated terminal block for direct wiring of the E-stop switch into the plant's physical safety relay circuit.

Empirical Engineering Insights

Alternative Models & Compatibility

This expansion panel is designed specifically for Beckhoff 15-inch displays. Attempting to fit this mechanical layout onto 12-inch or 19-inch variants will lead to misalignment of the chassis mating holes and failure of physical integration. For servicing older CP6x22 and CP7x22 variants, ensure the firmware revision of the host controller supports the dual-contact configuration over CP-Link if you intend to run control loops without auxiliary terminal-row wiring.

Application Pitfalls & Engineering Notes

A common design pitfall is attempting to hardwire the 14 integrated signal lamps. These lamps receive power and commands strictly through the USB/CP-Link bus connection. If the digital communication link is disrupted, the signal lamps will not function, even if the secondary NO contacts of the push-buttons remain functional via the hardwired terminal strip.

Commissioning & Wiring Tips

Always separate the hardwired digital input cabling connected to the secondary terminal row from high-voltage AC cables in the wire duct to prevent noise coupling on long runs. For high-vibration applications, verify that cable strain reliefs are anchored within the panel enclosure to prevent tension on the interface connector.

Installation Guidelines

CRITICAL WARNING: SAFETY COMPLIANCE REQUIRED

Isolate and lock out all electrical power supplying the Control Panel/Panel PC and all auxiliary terminal strip voltages before initiating the mechanical connection of the C9900-E768. The emergency stop circuit must undergo a full functional validation test before returning the machine to production.

1

Align the push-button extension housing with the pre-machined mounting points on the right-hand side of the 15-inch Control Panel.

2

Secure the mechanical assembly using the specified OEM fasteners, ensuring the integrated perimeter gasket forms a tight seal against dust and liquid ingress.

3

Connect the internal USB or CP-Link wiring harness to interface the button outputs and primary lamp controls with the panel's main logic board.

4

Wire the physical E-stop switch directly to your safety relay, and optionally terminate the redundant secondary NO contacts to your PLC's input modules via the integrated terminal strip.

Can the signal lamps on the C9900-E768 be hardwired directly to an external output block?

No. The 14 internal signal lamps are driven exclusively via the bus interface (CP-Link or USB). Direct physical terminal wiring is not available for these lamps.

How are the dual-contact push-buttons configured for control redundancy?

Each of the 14 push-buttons is equipped with two normally-open (NO) contacts. Contact 1 is transmitted electronically via USB/CP-Link, while Contact 2 is directly wireable to an physical I/O card using the built-in terminal strip.

Is the integrated emergency stop button active over the USB or CP-Link interface?

No. The Siemens Signum emergency stop button is completely isolated from the digital bus connection and must be hardwired directly to a safety controller or safety relay.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...