1 trong số 1

Beckhoff C9900-E871 CP6xxx CP7xxx Push-button Extension

Beckhoff C9900-E871 CP6xxx CP7xxx Push-button Extension

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: C9900-E871

  • Country of origin:Đức

  • Product Type: HMI Push-Button Extensions

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: drawings with dimensions of the push-button e x tensions as AutoCAD DXF file

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for direct integration onto the right side of Beckhoff CP6x32-00xx and CP7x32-00xx Control Panels, the Beckhoff C9900-E871 provides an auxiliary physical interface expansion for 15-inch HMI displays operating without an integrated keyboard. This rugged operator panel extension interfaces critical mechanical controls directly to the host control system, bridging physical actuation with digital bus communication. By incorporating industrial-grade switches and a dedicated emergency stop, it enhances spatial efficiency and operating convenience directly at the machine face.

Features

  • 18 Illuminated Push-Buttons: Equipped with high-durability Siemens Signum square keys (30 x 30 mm) containing integrated signal lamps.
  • Integrated Emergency Stop: Features one heavy-duty Siemens Signum emergency stop button designed for direct safety circuit integration.
  • Dual-Signal Routing: Transmits all push-button inputs via CP-Link or USB connection as a primary normally-open (NO) contact, with an independent secondary NO contact mapped directly to a terminal block.
  • Bus-Driven Indicator Lamps: Coordinates all signal lamp illumination strictly through CP-Link or USB communication protocols.
  • Customizable Legend Strips: Supports insertable label caps for rapid, application-specific functional engraving or text marking.

Applications

  • Automotive manufacturing assembly and machining cell control stations.
  • CNC machine tools and heavy industrial material handling systems.
  • Process control setups utilizing 15-inch fanless industrial PCs and HMI panels.
  • Safety-critical physical override environments demanding hardwired E-stop circuits.

Technical Specifications Table

Specification Parameter Value / Detail
Manufacturer Beckhoff Automation
Model Number C9900-E871
HMI Panel Compatibility CP6x32-00xx and CP7x32-00xx Series (15-inch without keyboard)
Mounting Location Right side of the HMI unit
Push-Button Element Type 18 x Siemens Signum Square (30 x 30 mm)
Emergency Stop Type 1 x Siemens Signum twist-to-release (direct-wireable)
Communication Interface USB or CP-Link (model dependent)
Contact Configuration (Buttons) 1st NO via USB/CP-Link; 2nd NO via terminal strip
Indicator Lamp Control Over bus interface (USB or CP-Link) only
Lifecycle Phase Service Phase (Legacy support and spare parts availability)
Shipping Weight (Calculated) 5.00 kg (11.02 lbs)

Connections and Interfaces

Terminal / Port Functional Assignment & Signal Type
USB / CP-Link Interface Primary communication bus interface; handles 1st NO contact inputs and drives active signal lamp outputs.
Direct Terminal Strip Access point for secondary isolated NO dry contacts for all 18 push-buttons; used for localized hardware interlocks.
Emergency Stop Terminals Hardwired NC contacts routed independently of the USB/CP-Link bus to interface directly with safety evaluation relays.

Empirical Engineering Insights

Alternative Models & Compatibility

The C9900-E871 is structurally sized to physically align only with 15-inch variants of the CP6x32 and CP7x32 control panels. If you are retrofitting a system with a different display size, this extension block will not mate correctly with the chassis mountings. Verify that the matching driver software or TwinCAT system manager configurations are set to recognize the USB-based keyboard emulation profile utilized by this extension.

Application Pitfalls & Engineering Notes

A common site failure involves trying to wire the 24V indicator lamps directly through the terminal strip. Note that the signal lamps are exclusively controlled via the digital USB or CP-Link connection. If your system application loses USB communication, the indicator lamps will remain dark, regardless of local direct terminal status. Ensure your PLC logic accounts for this behavior in high-duty environments.

Commissioning & Wiring Tips

To maintain compliance with Category 3 or 4 safety standards, never route the emergency stop signal through the USB/CP-Link bus. The integrated emergency stop button must be wired directly to an approved safety controller or monitoring relay utilizing the physical auxiliary contacts provided on the back of the extension assembly.

Installation Guidelines

CRITICAL WARNING:

Before starting mechanical mounting or electrical integration, completely isolate the 24V DC supply feeding the HMI Panel PC. Confirm the panel is fully de-energized to prevent short-circuits across the USB interface or secondary hardwired contacts during installation.

1

Align the C9900-E871 extension housing with the structural mounting points on the right-hand bezel of the CP6xxx/CP7xxx panel.

2

Secure the mechanical linkage using the supplied fasteners, taking care to maintain the target IP ingress protection rating at the joint interface.

3

Route and connect the internal USB or CP-Link wiring harness directly into the designated ports inside the main panel computer housing.

4

Interface the dedicated emergency stop contacts and hardwired push-button terminals into the local control cabinets, matching system wiring diagrams.

Can the push-button labels on the C9900-E871 be customized in the field?

Yes. The push-button caps on the C9900-E871 allow for individual insertion of printed label strips, allowing operators to mark functions according to system-specific requirements.

How are the push-button signals processed by the Beckhoff controller?

The buttons utilize a dual-contact scheme. The primary contact is transmitted digitally via USB or CP-Link, while a secondary normally-open contact is routed to a physical terminal block on the rear for direct PLC input cards or hardwired loops.

Is it possible to light up the key indicator lamps using external 24V digital outputs?

No. The indicator signal lamps are driven exclusively via the USB or CP-Link connection. There are no physical terminal block connection points to power the lamps directly.

What display sizes are compatible with this mechanical extension?

The C9900-E871 is engineered and dimensioned to physically mate with 15-inch Beckhoff CP6x32-00xx and CP7x32-00xx Control Panels and Panel PCs.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...