1 trong số 1

Beckhoff CX1500-M200 CX Series Lightbus Master Connection Module

Beckhoff CX1500-M200 CX Series Lightbus Master Connection Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX1500-M200

  • Country of origin:Đức

  • Product Type: PLC Communication Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 38 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Designed for seamless integration within modular industrial control environments, the Beckhoff CX1500-M200 fieldbus master connection establishes high-speed Lightbus communications directly from a compatible CX-series CPU. By utilizing fiber optic physical layers, this interface module guarantees complete electrical isolation and exceptional noise immunity across distributed field systems. The integration with the host controller is achieved through a high-bandwidth 2 kbytes DPRAM interface over an ISA plug-and-play architecture, ensuring rapid cyclic data exchanges. Perfect for synchronized motion and distributed I/O systems, the device supports both free-running and synchronized process data communication modes depending on the application requirements.

Features

  • High-Speed Transmission: Supports a fixed 2.5 Mbaud data transfer rate, capable of cycling 32 bits of process data in 25 microseconds.
  • Fiber Optic Physical Layer: Equipped with dual fiber optic interfaces to prevent electromagnetic interference and ground loops.
  • Large Network Capacity: Manages up to 254 distinct nodes with an aggregate capacity of up to 65,280 industrial I/O points.
  • TwinCAT Integration: Direct hardware driver compatibility with the TwinCAT 2 software platform for simplified system configuration.
  • Industrial Durability: Robust IP20 enclosure rated to withstand harsh mechanical vibration and thermal environments.

Applications

  • High-speed multi-axis motion synchronization over fiber optic rings.
  • Industrial manufacturing plants with severe electromagnetic noise and interference.
  • Distributed telemetry systems and high-density I/O networking over extended distances.
  • Legacy machine retrofits and maintenance of TwinCAT 2 control architectures.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / Article Number CX1500-M200
Fieldbus System Lightbus
Data Transfer Rate 2.5 Mbaud
Process Data Cycle Time 32 bits in 25 microseconds
Bus Interface 2 x fiber optic ports
Maximum Nodes 254 nodes (max. 65,280 I/O points)
CPU Interface ISA plug and play, 2 kbytes DPRAM
Max. Power Loss 2 W
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Driver Support Compatible only with TwinCAT 2
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Dimensions (W x H x D) 38 mm x 100 mm x 91 mm
Net Weight 190 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Interface Type Function / Assignment
Optical Port 1 (Tx) Lightbus optical transmitter connection to the ring network.
Optical Port 2 (Rx) Lightbus optical receiver connection completing the ring loop.
Backplane Interface Integrated PC104/ISA Bus for physical connection and power distribution from the CX CPU.

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1500-M200 is designed exclusively for CX-series hardware configurations operating under TwinCAT 2 runtimes. It cannot be mapped or configured under TwinCAT 3 due to the hardware-level dependencies of the legacy ISA DPRAM address space. Ensure your system CPU supports PC104 expansion channels before engineering replacements.

Application Pitfalls & Engineering Notes

When laying optical fiber cables for the Lightbus loop, strictly adhere to the manufacturer's specified minimum bending radius. Kinking or over-bending the optical fibers causes critical light signal attenuation, leading to intermittent cyclic redundancy check (CRC) errors or complete bus synchronization failures.

Commissioning & Wiring Tips

Always power down the control stack before cleaning or inserting optical fiber connectors. Dust ingress within the active physical transceivers can permanently degrade light output. Prior to initial startup, verify the mechanical alignment of the CPU extension connector to avoid bent pins on the backplane.

Installation Guidelines

CRITICAL WARNING:

Isolate and lock out all power sources feeding the host controller and connected field devices before initiating module insertion or removal. Failing to perform total system de-energization may damage the sensitive DPRAM physical layer of the host CPU and invalidate your warranty.

1
Power down the main control cabinet and verify that no residual energy remains in any auxiliary supply lines.
2
Mount the module directly onto the standard DIN rail (TS35), sliding it towards the host CX controller stack until the backplane contacts engage firmly.
3
Secure the stack by snapping end brackets on both sides of the assembled system to prevent side-to-side drift or mechanical disconnection.
4
Connect the incoming and outgoing fiber optic cables, confirming that the Tx (transmit) line connects to the corresponding Rx (receive) port of the adjacent field node.

Is this Lightbus module compatible with TwinCAT 3?

No, this connection module is strictly compatible with TwinCAT 2 and does not support TwinCAT 3 environments due to legacy driver structures.

What is the maximum node capacity of the system?

The master interface can control up to 254 nodes, supporting a maximum of 65,280 physical I/O points.

What are the interface cycle times for process data?

The module transfers 32 bits of process data in 25 microseconds at a physical baud rate of 2.5 Mbaud.

What type of cabling is required for the bus interface?

It requires standard fiber-optic cables (2x interface ports) supporting the Lightbus ring configuration.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Đức

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...