1 trong số 3

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 136711-02

  • Country of origin:Hoa Kỳ

  • Product Type: RTD/TC I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 460g

  • Dimensions: 24.4 mm x 241.3 mm x 163.1 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The Bently Nevada 136711-02 is a non-isolated RTD/TC I/O module with internal barriers and internal terminations designed for processing temperature transducer inputs within the 3500 Machinery Protection System. Installed in a full-height rear slot directly behind the 3500/61 Temperature Monitor main module, it accepts input signals from up to six Resistance Temperature Detector (RTD) or Thermocouple (TC) transducers. The 136711-02 channels conditioned signals and +4 to +20 mA proportional recorder outputs through integrated internal barriers to support intrinsically safe machinery monitoring applications in industrial environments.

Features

  • Provides internal zener barriers and internal termination wiring connectors for six input channels
  • Interface options configurable for 3-wire RTD, 4-wire RTD, and Thermocouple transducers
  • Integrates directly behind the 3500/61 Temperature Monitor via the 3500 system backplane
  • Routes +4 to +20 mA proportional recorder outputs for each individual channel

Applications

  • Bearing temperature monitoring in rotating machinery such as turbines, compressors, and pumps
  • Process temperature measurement using RTD and TC transducers in hazardous location areas
  • Machinery protection and condition monitoring within the 3500 system architecture

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Part Number 136711-02
Compatible Main Module 3500/61 Temperature Monitor
Module Type RTD/TC Non-Isolated I/O Module with Internal Barriers and Internal Terminations
Number of Channels Accepts 1 to 6 RTD or TC transducer signals
Input Impedance Greater than 10 Mohm for each lead input
Thermocouple Types Type E (-100 degC to +1000 degC), Type J (0 degC to +760 degC), Type K (0 degC to +1370 degC), Type T (-160 degC to +400 degC)
RTD Types 100 ohm 3-wire & 4-wire platinum (alpha = 0.00385 or 0.00392), 120 ohm 3-wire & 4-wire nickel, 10 ohm 3-wire & 4-wire copper
RTD Current Source Value 925 +-15 uA at 25 degC per transducer
Recorder Outputs +4 to +20 mA proportional to monitor full-scale (individual per channel)
Voltage Compliance (Current Output) 0 to +12 Vdc range across load (0 to 600 ohm load resistance)
Recorder Output Resolution 0.3662 uA per bit +-0.15% error at room temperature (+-0.4% error over temperature range)
Operating Temperature 0 degC to +65 degC (32 degF to +150 degF) when used with Internal Barrier I/O Modules
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Rack Space Requirement 1 full-height rear slot
Dimensions (H x W x D) 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
Weight 0.46 kg (1.01 lbs)

Installation Guidelines

  • Install the I/O module in a single full-height rear slot positioned directly behind the corresponding 3500/61 Temperature Monitor module.
  • Secure wiring connections to the green and blue internal termination connector headers according to transducer type wiring configurations.
  • Ensure operating ambient temperatures remain within the designated limit of 0 degC to +65 degC when internal barriers are active.

Compliance and Certifications

Certification / Standard Standard / Details
EMC Directive 2004/108/EC (EN 61000-6-2, EN 55011/CISPR 11, EN 61000-6-4)
Low Voltage Directive 2006/95/EC (EN 61010-1)
North American Hazardous Area Approval Ex nC [ia] IIC: Class I, Div 1; AEx nC [ia] IIC: Class 1, Zone 2/0 Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC
ATEX Approval II 3/(1) G, Ex nC[ia Ga] IIC T4 Gc, T4 @ Ta = -20 degC to +65 degC
Brazil Approval (3500/61 only) BR-Ex nC[nL] IIC T4, T4 @ Ta = -20 degC to +65 degC
South Africa Approval Ex nCAL [ia] IIC T4, Ex nCAL [L] IIC T4, T4 @ Ta = -20 degC to +65 degC
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 136711-02 3500/61 RTD/TC I/O Module with Internal Barriers and Internal Terminations

Which slot position does the module occupy in the chassis?

The module installs in a full-height rear slot directly behind the 3500/61 Temperature Monitor main card.

What transducer inputs can be connected to the terminals?

The module accepts up to six RTD or Thermocouple inputs, including Type E, J, K, and T thermocouples or platinum, nickel, and copper RTDs.

What temperature range is permitted for module operation?

The operating temperature range is 0 degC to +65 degC when deployed with internal barrier I/O configurations.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Hiện đại hóa HMI Bailey INFI 90 Symphony chạy trên OpenVMS Alpha

Hướng dẫn thực tiễn về việc thay thế các trạm vận hành Bailey Symphony đã cũ chạy trên OpenVMS Alpha. Tài liệu so sánh phương án giả lập Alpha, chuyển đổi sang OpenVMS x86, tái nền tảng OPC và hiện...

Vì sao dữ liệu bảo trì thiết yếu đối với độ tin cậy trong công nghiệp

Dữ liệu bảo trì kết nối các lệnh công việc, tín hiệu cảm biến, lịch sử tài sản, chi phí và kiến thức của kỹ thuật viên. Khi được sử dụng hiệu quả, dữ liệu này giúp cải thiện công tác lập kế hoạch, độ...

Bộ truyền động điện được thiết kế để thay thế hệ thống truyền động chất lỏng: Hướng dẫn thực tiễn về tự động hóa công nghiệp

Bài viết này giải thích cách các bộ truyền động điện tích hợp, chẳng hạn như dòng e-Actuator của SMC, đang chuyển đổi hoạt động điều khiển chuyển động trong công nghiệp bằng cách thay thế các hệ...

Các phép toán bằng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện những phép toán cốt lõi như cộng, trừ, nhân, chia, chia lấy dư và lũy thừa trong tự động hóa công nghiệp. Bài viết trình bày cách các khối hàm...