1 trong số 1

Bently Nevada 3500/60-01-00 3500 Series Temperature Monitor Module

Bently Nevada 3500/60-01-00 3500 Series Temperature Monitor Module

Only 2 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 3500/60-01-00

  • Country of origin:Hoa Kỳ

  • Product Type: Machinery Protection System Modules

  • Payment: T/T, Western Union

  • Weight: 320g

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

Processing and continuous monitoring of temperature inputs within critical machinery protection systems is executed by the Bently Nevada 3500/60-01-00, a dedicated 3500 Series module configuration. This specialized module processes signals from both Resistance Temperature Detectors (RTDs) and Thermocouples (TC) to provide continuous, high-accuracy temperature tracking. Designed without recorder outputs, the 3500/60-01-00 utilizes an RTD/TC Non-Isolated I/O Module with Internal Terminations to maximize channel density and simplify wiring architectures directly within the monitor rack. It operates with a nominal power consumption of 7 watts, ensuring minimal thermal load inside the enclosure while delivering steady performance for machinery protection.

Features

  • Dual Sensor Compatibility: Dynamically processes inputs from both RTD and Thermocouple sensors on a single module frame.
  • Internal Terminations: Integrated wiring terminals reduce cabinet space requirements and simplify field installations.
  • High-Accuracy Monitoring: Delivers precise temperature verification for machinery components without the need for external signal conditioning.
  • Integration Integrity: Communicates directly with the 3500 System's backplane for high-speed alarm and trip generation.
  • Compact Form Factor: Fits into standard 3500 rack slots, supporting high-density machinery protection layouts.

Applications

  • Steam, gas, and hydro turbine bearing temperature monitoring.
  • Large industrial motor and generator winding protection.
  • Compressor and high-pressure pump casing thermal monitoring.
  • Gearbox and bearing oil sump temperature supervision.

Technical Specifications

Manufacturer Bently Nevada
Model Number 3500/60-01-00
Series 3500 Series Machinery Protection System
I/O Module Type 01 - RTD/TC Non-isolated I/O Module
Termination Type Internal Terminations
Power Consumption 7 Watts (Nominal)
Agency Approval Option 00 - None
Recorder Outputs None
Country of Origin United States (USA)
Shipping Weight 2.0 kg

Alternative Models & Compatibility

The 3500/60-01-00 configuration utilizes a non-isolated I/O interface. If your site electrical design requires isolation to protect against high common-mode voltages or severe field noise, consider the 3500/60-02-00 variant, which integrates isolated I/O modules. Ensure that any replacement of the I/O module is matched by a corresponding configuration update within the 3500 Rack Configuration Software to prevent system configuration faults (slot mismatch errors).

Application Pitfalls & Engineering Notes

Because this module utilizes non-isolated I/O (Option 01), it shares a common ground across channels. It is critical that the RTD or thermocouple sensor tips installed on the machinery are electrically isolated from the machine frame. If a sensor tip becomes grounded to the machine frame, ground loops and common-mode voltages will degrade temperature readings, cause erratic measurements, or trigger false alarms. Always verify sensor insulation resistance during routine maintenance cycles.

Commissioning & Wiring Tips

When wiring to the internal termination block, use shielded, twisted-pair cables for all temperature sensor runs. Connect the shield drain wire only at the designated terminal on the 3500/60 I/O module. Do not connect the shield at the sensor junction box, as this will establish a ground loop. Keep signal wiring physically separated from high-voltage AC power lines to avoid electromagnetic interference on sensitive thermocouple readings.

Installation Guidelines

CRITICAL WARNING

De-energize the 3500 rack and all connected field circuitry before installing or removing modules. Live-plugging under load, especially on field I/O connections, poses a risk of electrical damage to the module circuitry and may cause unexpected tripping of connected machinery protection loops.

1
Ensure the 3500 rack power supplies are switched off and safety lockouts are active.
2
Align the main monitor module with the front slot guide rails and push firmly until the connector seats fully into the backplane. Secure the front panel screws.
3
Install the non-isolated I/O module (internal terminations) into the corresponding rear slot of the rack and secure the fastening screws.
4
Wire the RTD or Thermocouple sensors to the terminal strip following the designated pinout diagrams, ensuring shield wires are correctly terminated at the rack end.
5
Power up the rack and upload the correct software configuration using the 3500 Rack Configuration utility. Verify there are no system fault LEDs lit.

What is the primary difference between isolated and non-isolated modules in this series?

Non-isolated I/O modules, such as the 01-option on this monitor, share a common ground across channels. They require electrically isolated RTD or Thermocouple sensors at the machine to prevent ground loop noise from corrupting data.

Can I mix RTD and Thermocouple sensors on the same monitor module?

Yes, this monitor accepts inputs from both RTD and Thermocouple sensors, but individual channel configurations and sensor types must be properly mapped using the system's rack configuration software.

Does this module include recorder outputs?

No, this specific configuration has the option suffix -00 for recorder outputs, meaning it does not supply external analog outputs for chart recorders.

How should cable shields be terminated for this temperature module?

Shields must be terminated solely at the designated shield terminals on the internal termination I/O module at the rear of the rack. Do not ground the shield at the sensor junction box.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...