1 trong số 3

Bently Nevada 991-25-50-01-01 991 Thrust Transmitter

Bently Nevada 991-25-50-01-01 991 Thrust Transmitter

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 991-25-50-01-01

  • Country of origin:Hoa Kỳ

  • Product Type: Thrust Transmitter

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 430g

  • Dimensions: 53.3 mm x 73.9 mm x 100.1 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Description

The Bently Nevada 991-25-50-01-01 is a two-wire, loop-powered thrust transmitter designed to measure the relative axial position of a rotating machine shaft. It accepts input directly from a 3300 NSv proximity probe and extension cable, transforming the proximity signal into a proportional 4 to 20 mA current output. This device integrates directly with Programmable Logic Controllers (PLCs), Distributed Control Systems (DCSs), and SCADA networks to provide continuous machinery protection and condition monitoring. Typical industrial applications include centrifugal air compressors, small pumps, motors, and fans with fluid-film thrust bearings where a full machinery protection system monitor rack is not required.

Features

  • Two-wire, 4 to 20 mA loop-powered current output
  • Designed for non-contacting shaft axial displacement measurement
  • Compatible with 3300 NSv proximity probe and extension cable
  • Integrated BNC connector for dynamic vibration signal access and diagnostics
  • DIN rail or panel mounting configurations
  • Non-interacting zero and span adjustments
  • Potted construction for high humidity environments up to 100% condensing
  • Not OK/Signal Defeat circuit to prevent false alarms due to faulty proximity probes or loose connections

Applications

  • Centrifugal air compressors
  • Process pumps and industrial motors
  • Steam and gas turbines
  • Electric motors with thrust bearings
  • Cooling tower fans and blowers

Ordering Information

Option Code Description
991 Thrust Transmitter
25 Full-scale Option: 25-0-25 mils
50 System Length Option: 5.0 meters (16.4 feet)
01 Mounting Option: 35 mm DIN-rail clips
01 Agency Approval Option: CSA Division 2

Technical Specifications

Category Parameter Specification
Manufacturer Brand Bently Nevada
Origin Country of Origin United States
Physical Approximate Weight 0.43 kg
  Dimensions (H x W x D) 53.3 mm x 73.9 mm x 100.1 mm (2.10 in x 2.91 in x 3.94 in)
  Body Height (without DIN clip) 42.6 mm (1.68 in)
  Mounting Hole Distance (Width x Length) 63.5 mm x 69.9 mm (2.50 in x 2.75 in)
  Mounting Hole Diameter 5.8 mm (0.23 in)
Electrical Input Voltage Range 12 to 35 Vdc (at the transmitter terminal block)
  Current Output 4 to 20 mA (Linear over 50 mils range)
  Loop Accuracy Within ±1.5% over specified full-scale range
  Maximum Loop Resistance 1000 ohms including cable at 35 Vdc
  Current Limiting 23 mA typical
Dynamic Frequency Response DC to 10 Hz
  BNC Connector Output Raw proximity probe voltage buffered (Nominal 200 mV/mil)
  Minimum Target Size 9.5 mm diameter
Environmental Operating Temperature -35 to +85 Celsius
  Storage Temperature -51 to +100 Celsius
  Relative Humidity 100% condensing, non-submerged

Connections/Interfaces

Terminal / Connector Function
PROX Proximity Probe Input Terminal Connection
COM Signal Common / System Ground
+4-20mA Positive Loop Power / Current Output Terminal
-4-20mA Negative Loop Power / Current Output Terminal
BNC Dynamic Signal Output (Buffered Proximity Voltage)

Installation Guidelines

Dimensions and Mounting

The module accommodates both panel (bulkhead) and DIN rail mounting options. When using the panel mount configuration, prepare four mounting holes with a spacing layout of 63.5 mm (width) by 69.9 mm (length). Use the standard 5.8 mm diameter mounting holes or the supplied 6-32 x 1.326 screws for secure bulkhead fixation. For DIN rail configurations, ensure a standard 35 mm DIN rail is rigidly installed before snapping on the transmitter's DIN mount clips.

Grounding and Shielding

Proper grounding is essential to minimize noise interference. The transmitter must be mounted to a grounded plate or a grounded DIN rail. Ensure the cable shield is grounded at only one end, typically at the control room/DCS side, to prevent ground loops.

Probe Gap Adjustment

Before final commissioning, the proximity probe must be physically positioned (gapped) relative to the shaft target. Adjust the gap until the transmitter output reads approximately 12 mA, which corresponds to the midpoint of the linear thrust range (0 mils).

Cable Routing

Run probe and loop cables in dedicated, grounded metal conduits or cable trays. Avoid routing transmitter cables parallel to high-voltage AC power lines or heavy machinery switching circuits to prevent electro-magnetic interference (EMI).

Hazardous Area Precautions

When installed in classified areas, appropriate intrinsic safety barriers or explosion-proof housings must be utilized in accordance with local electrical codes and the specific installation drawings provided by the manufacturer.

FAQ

What is the primary function of this thrust transmitter?

It measures the axial displacement or thrust position of a rotating machine shaft relative to a fixed reference point using a non-contacting proximity probe.

What type of probe system is compatible with this transmitter?

It is designed specifically to interface with a Bently Nevada 3300 NSv proximity probe and extension cable system.

How is the device powered?

It is a loop-powered device operating on a 12 to 35 Vdc supply connected via the 4 to 20 mA current loop.

What does the BNC connector provide?

The BNC connector provides a buffered raw voltage signal proportional to the probe gap distance, allowing engineers to connect diagnostic equipment like oscilloscopes or analyzers without disconnecting the loop.

Can this device be used for radial vibration measurements?

No, this specific model is configured and calibrated for thrust (axial) position measurement. For radial vibration, a 990 Vibration Transmitter should be used.

What is the function of the Not OK/Signal Defeat circuit?

The circuit forces the signal output to drop below 3.6 mA within 100 microseconds of a probe fault or loose connection to prevent false alarms in the control system.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 991-25-50-01-01 991 Thrust Transmitter

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Trắng xám Đen
Country of origin
Hoa Kỳ
Power source
Nguồn điện DC

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...