  • Manufacturer: General Electric

  • Product No.: UR-8GH

  • Country of origin:Hoa Kỳ

  • Product Type: 4 CT/4 VT Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1350g

  • Dimensions: 15 cm x 18 cm x 4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The UR-8GH (UR8GH) is a high-precision analog data acquisition interface engineered by General Electric for the UR Series (Universal Relays) network protection ecosystem. Functioning as a high-density primary scaling block, this critical card safely steps down high-capacity voltage and current dynamics from field instrument transformers into millivolt processing lines for the relay's arithmetic core. Power distribution infrastructures—including extra-high voltage transmission switchyards, automated hydroelectric stations, and heavy petrochemical processing facilities—rely on the UR-8GH (UR8GH) to capture sub-cycle line disturbances and voltage phase fluctuations. By providing 4 CT (Current Transformer) and 4 VT (Voltage Transformer) galvanically isolated input channels on a single substrate, this module ensures accurate real-time line calculation metrics, shortens breaker response profiles during high-current line faults, and minimizes plant unprogrammed downtime.

Technical Configuration & Sensor Interfacing

The advanced structural wiring matrix, channel segregation filters, and operational frequency boundaries of the UR-8GH measurement module govern its grid monitoring precision.

  • Dual-Source Parameter Ingestion: Features a balanced 4 CT and 4 VT channel grid configuration designed to track three-phase voltage and current lines simultaneously along with an independent neutral ground path.

  • Galvanic Protection Boundaries: Implements an advanced structural isolation barrier between the terminal connection block and the internal processing backplane, preventing severe inductive fault spikes from damaging the core CPU processor.

  • Sub-Sample Phase Synchronization: Operates in perfect synchronization with the Universal Relay backplane logic, ensuring zero phase-angle skewing between corresponding current and voltage waveform samplings.

  • Dynamic Grid Mapping Matrix: Transmits high-fidelity analog values to the host system firmware to support complex protective logic paths, including distance protection (21), directional overcurrent (67), and synchronized line monitoring telemetry.

Technical Specifications

Protection Metric Factory System Specification Standard
Model Designation UR-8GH
Brand Manufacturer GE Multilin (General Electric Grid Solutions)
Control System Line UR Series Universal Relays Platform
Module Classification 4 CT / 4 VT Standard Analog Input Module
Current Inputs (CT) 4 Isolated Channels with high continuous thermal bounds
Voltage Inputs (VT) 4 Isolated Channels optimized for instrumentation lines
Frequency Tracking Bounds 50 Hz / 60 Hz Nominal Grid Compatibility
Data Log Resolution High-speed multi-sampling analog-to-digital matrix
Configuration Software EnerVista UR Configuration Utility Platform
Physical Dimensions Standard UR Expansion Slot Case (approx. 15 cm x 18 cm x 4 cm)
Hardware Shipping Weight 1.35 kg
Operating Temperature Window -40 to +60 deg C Continuous Environmental Range
Manufacturing Location Markham, Ontario, Canada

Protection System & Diagnostic FAQs

How do system engineers verify individual CT/VT calibration or troubleshoot open-circuit metrics on the UR-8GH?

Live analog vector measurements can be evaluated passively via the front LCD panel of the Universal Relay chassis or diagnosed directly through the EnerVista UR software workspace. This programming environment displays real-time current magnitude graphs, phase angles, and harmonic wave distortions, allowing immediate diagnosis of current transformer phase reversals or ungrounded neutral lines.

What are the consequences of an unprogrammed open-circuit fault crossing an active UR-8GH current transformer channel?

An open-circuit condition on an active CT secondary loop generates dangerous high-voltage transients across the terminal block pins, posing a lethal shock hazard to personnel and causing dielectric breakdown within the module's input circuitry. Technicians must ensure that shorting blocks are securely engaged prior to disconnecting any current line terminal screws.

Can the UR-8GH module be swapped or inserted while the utility automation panel remains live?

No. To prevent lethal induced voltages from open CT lines, accidental tripping of live substation breakers, or damage to the internal backplane microprocessor from electrical arcs, you must completely isolate all power and current transformer sources from the relay enclosure before extracting or seating any module.


Field Engineering & Installation Protocol

  • Terminal Screw Landing Constraints and Torque Specifications:

    When landing heavy instrument transformer leads onto the terminal block of the UR-8GH, utilize high-integrity ring terminals to prevent wire pullouts. Insert wire links cleanly and tighten terminal screws to an exact torque profile of 1.4 N-m (12.4 inch-lbs). Loose current terminal connections cause resistive heating and can induce high-voltage arcing that destroys the underlying PCB solder points.

  • Twisted-Pair Shielding and Noise Suppression Guidelines:

    Route all sensitive analog current and voltage transformer secondary circuits through dedicated, shielded twisted-pair instrumentation lines. Ground the cable shields at a single point inside the relay panel enclosure only. This installation rule blocks high-frequency electromagnetic noise generated by adjacent high-voltage circuit breakers from distorting the relay's phase-angle measurements.

  • Module Insertion Security and Grounding Path Integrity:

    Carefully slide the UR-8GH board into its designated panel slot using the built-in plastic guide rails to protect the rear multi-pin pinout from alignment damage. Push the module home until its metal faceplate sits completely flush against the chassis housing, and tighten all exterior retention screws to a maximum torque profile of 0.6 N-m (5.3 inch-lbs). This structural connection establishes a low-resistance earth ground path to protect the internal data acquisition components from heavy substation electromagnetic interference (EMI).

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Đen
Country of origin
Hoa Kỳ

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...