1 trong số 3

IOC16T 200-565-000-013 Vibro-Meter Input/Output Card for VM600

IOC16T 200-565-000-013 Vibro-Meter Input/Output Card for VM600

Only 7 item(s) left in stock
  • Manufacturer: VIBRO-METER

  • Product No.: VM600 IOC16T 200-565-000-013

  • Country of origin:Hoa Kỳ

  • Product Type: Input/Output Card

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 480g

  • Dimensions: 3.2cm x 10.6cm x 13cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Số lượng
Xem toàn bộ chi tiết

Product Overview

The IOC16T 200-565-000-013 (IOC16T) is a high-density input/output communication card designed for the Vibro-Meter VM600 rack system. Functioning as the rear-panel interface for the MPC4 machinery protection card or as a standalone signal aggregator, the IOC16T facilitates the physical connection of up to 16 dynamic or quasi-static signals. It is primarily utilized in large-scale TSI (Turbine Supervisory Instrumentation) and condition monitoring applications where extensive sensor integration is required. The 200-565-000-013 provides a robust connection point for field wiring, ensuring signal integrity is maintained from the transducer to the digital processing environment of the VM600 backplane.

Technical Configuration (Deep Dive)

The 200-565-000-013 configuration is built for reliability in high-interference industrial environments, featuring specific I/O routing for complex monitoring tasks.

  • 16-Channel Capacity: Unlike standard 4-channel I/O cards, the IOC16T handles up to 16 channels, making it ideal for monitoring multiple bearings or large-scale auxiliary equipment in power plants.

  • Terminal Block Integration: Equipped with high-quality screw-terminal connectors that support secure field wiring and easy maintenance without disturbing the front-end processing cards.

  • Signal Routing: It acts as a passive or active bridge (depending on configuration) that routes raw sensor data to the processing modules while providing buffered outputs for external analysis tools.

  • Protection Circuitry: Includes internal surge protection and EMI filtering to prevent transient voltage spikes from damaging the internal VM600 VME bus architecture.

Technical Specifications

Parameter Specification Details
Model IOC16T 200-565-000-013
Brand Vibro-Meter (Meggitt)
Origin Switzerland
Channel Count 16 Input/Output Channels
Card Type Rear-panel I/O Module
Operating Temp -25 to 65 deg C
Weight 0.48 kg
Connection Type Screw Terminal Blocks
Dimensions 6U Height, Single Slot Width

Technical FAQs

Can the IOC16T 200-565-000-013 be used with any VM600 card?

The IOC16T is specifically designed to pair with processing cards that require high-density I/O. It is most commonly used in conjunction with MPC4 or AMC6 modules. Always verify the backplane compatibility in your specific rack configuration.

How do I handle signal noise on the 16-channel inputs?

Ensure that the twisted-pair sensor cables are correctly landed on the differential input terminals. The IOC16T provides dedicated ground/shield pins; these should be the only ground point for the cable shields to prevent the introduction of 50/60 Hz noise.

Is this card hot-swappable?

Yes, but with caution. While the physical interface can be disconnected, removing an IOC16T while the machine is running will break the protection loop for all 16 channels, likely triggering a system-wide trip if not bypassed in the software first.


Engineering & Installation Guide

  • Wiring Sequence: When wiring 16 channels, use a systematic labeling approach. Start from the bottom terminals and work upwards to ensure clear visibility and access. Use ferruled wire ends to prevent "stray strands" from short-circuiting adjacent high-density terminals.

  • Backplane Alignment: The IOC16T must be inserted into the rear slot exactly corresponding to the front processing card. The DIN 41612 connectors are precise; ensure the card is perpendicular to the backplane before applying seating pressure to avoid pin damage.

  • Thermal Management: In a fully loaded VM600 rack, 16-channel cards can contribute to cable bundle heat. Ensure sufficient clearance behind the rack for airflow and avoid tightly packing signal cables which can trap heat near the terminal blocks.

Engineering Advantages

The IOC16T 200-565-000-013 is prized for its Space-to-Channel Efficiency. By consolidating 16 channels into a single rear-slot footprint, it allows for significantly smaller rack configurations in crowded control rooms. Furthermore, its "Transparent Signal Path" ensures that the raw analog waveforms from proximity probes and accelerometers are delivered to the processing card with zero phase-shift and minimal attenuation, which is critical for accurate FFT and orbit analysis in turbine diagnostics.

Vận chuyển nhanh toàn cầu

  • Giao hàng tiêu chuẩn: 4-6 ngày làm việc qua DHL, FedEx và UPS.
  • Giao hàng nhanh: Giao hàng trong ngày cho đơn đặt hàng có sẵn trong kho trước 2:00 chiều (GMT+8).
  • Phủ sóng toàn cầu: Phục vụ hơn 150 quốc gia, bao gồm giao hàng nhanh đến Saudi Arabia và UAE.

Trả hàng & Bảo hành

  • Đảm bảo 30 ngày: Chấp nhận trả hàng cho sản phẩm có sẵn trong kho với bao bì nguyên bản, niêm phong từ nhà máy.
  • Bảo hành 12 tháng: Mỗi linh kiện công nghiệp đều được bảo hành kỹ thuật chuyên nghiệp.

Đơn hàng được xử lý và giao từ thứ Hai đến thứ Sáu (không bao gồm ngày lễ).


Để biết đầy đủ điều kiện, phí lưu kho và chi tiết trả hàng quốc tế, vui lòng xem trang chính thức của chúng tôi Chính sách Hoàn tiền & Trả hàng .

TECHNICAL SPECIFICATIONS

Color pattern
Nhiều màu sắc Xanh lá cây
Country of origin
Hoa Kỳ

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Sản phẩm đã xem gần đây

Kiến thức kỹ thuật

Bộ truyền động điện được thiết kế để thay thế hệ thống thủy lực: Hướng dẫn tự động hóa công nghiệp thực tiễn

Bài viết này giải thích cách các bộ truyền động điện tích hợp, như dòng e-Actuator của SMC, đang thay đổi điều khiển chuyển động công nghiệp bằng cách thay thế các hệ thống khí nén và thủy lực truyền...

Các phép toán toán học sử dụng OpenPLC cho các ứng dụng tự động hóa công nghiệp

Bài viết này giải thích cách các hệ thống PLC thực hiện các phép toán cơ bản như cộng, trừ, nhân, chia, modulo và lũy thừa trong tự động hóa công nghiệp. Nó trình bày cách các khối chức năng này...

Logic Boolean Nâng Cao với Lập Trình PLC FBD: Ứng Dụng Công Nghiệp Thực Tiễn Vượt Xa Logic Cơ Bản

Bài viết giải thích một số hàm logic Boolean nâng cao được sử dụng trong lập trình PLC ngoài các phép toán cơ bản AND, OR và NOT. Nó trình bày cách các công cụ như bảng chân trị, bộ chọn đa kênh, bộ...

Logic Boolean trong Lập trình PLC: Hiểu về Cổng Logic FBD

Logic Boolean là nền tảng của mọi chương trình PLC. Từ các điều khiển máy đơn giản đến các hệ thống tự động hóa công nghiệp phức tạp, các cổng logic quyết định cách các bộ điều khiển phản ứng với các...

Hướng Dẫn Chi Tiết Về Tường Lửa Công Nghiệp và Phân Vùng Mạng OT

Tường lửa công nghiệp đóng vai trò quan trọng trong an ninh mạng OT, bảo vệ các mạng PLC, DCS và SCADA thông qua phân đoạn, kiểm soát truy nhập/ra vào và tích hợp IDS/IPS phù hợp với các nguyên tắc...

Hướng dẫn về Càng Robot: Từ Xử lý Nhẹ Nhàng đến Tự động Hóa Công Suất Nặng

Các bộ kẹp robot hiện đại đang phát triển vượt ra ngoài các hàm cơ học truyền thống. Từ hệ thống dính lấy cảm hứng từ tắc kè, bộ kẹp mềm đạt chuẩn thực phẩm đến các công cụ kho hàng được trang bị trí...